Refer to Table 5.4-12 Offset setting for details. (1) (2) Offset setting Table 5.4-12 Offset setting No. Indication Item Explanation Setting range (1) Offset Temp.
M6 x 1.0 52 8 10 28 5.4 9 55 10 6 7 25 10 to 50, 75, 100 96.5 M6 x 1.0 84.5 12 12 45 13.5 M6 x 1.0 60 4.5 10 12 34 5.5 9 58 10 49.5 7 7 28 10 to 50, 75, 100 116 M8 x 1.25 104 13 16 52 17.5 M6 x 1.0 69 5 14 12 40 5.5 9 71 10 57 10 7 With rod end male thread: MQQDM Rod end nut H1 Bore size (mm) L1 C1 H1 X 10 23.5 10.5 M5 x 0.8 15.5 16 26.5 11.5 M6 x 1.0 16.5 C1 20 28.5 13.5 M8 x 1.25 18.5
M6 x 1.0 52 8 10 28 5.4 9 55 10 6 7 25 10 to 50, 75, 100 96.5 M6 x 1.0 84.5 12 12 45 13.5 M6 x 1.0 60 4.5 10 12 34 5.5 9 58 10 49.5 7 7 28 10 to 50, 75, 100 116 M8 x 1.25 104 13 16 52 17.5 M6 x 1.0 69 5 14 12 40 5.5 9 71 10 57 10 7 With rod end male thread: MQQDM Rod end nut H1 Bore size (mm) L1 C1 H1 X 10 23.5 10.5 M5 x 0.8 15.5 16 26.5 11.5 M6 x 1.0 16.5 C1 20 28.5 13.5 M8 x 1.25 18.5
4 4 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [oC] Circulating fluid temperature [oC] 50Hz 60Hz Fig. 8-6 Cooling capacity(HRS150-A-20/40/46/46-) 8.4 Cooling capacity HRS Series 8-12 HRX-OM-S004 Chapter 8 Documents : Facility water temperature 32 oC 8.4.3 HRS100-W-20/40/46: Facility water temperature 40 oC 14 14 12 12 10 10 Cooling capacity [kW] Cooling
6.2 6.2 3.8 6.2 6.2 1.8 6.2 6.2 5.8 6.2 6.2 3.8 16 6.7 6.7 3.3 6.7 6.7 1.3 6.7 6.7 5.3 6.7 6.7 3.3 20 7.5 10 7.5 10 7.5 10 2 7.5 10 25 8 12 8 12 8 12 8 12 Auto Switch Mounting Height U [mm] Auto switch model Bore size D-M9V, D-M9WV, D-M9AV U 12 19.5 16 21 20 23 25 24.5 W A B A Operating Range [mm] Auto switch model Applicable bore size 12 16 20 25 D-M9m(V)/M9mW(V)/M9mA(V) 3 3 4.5
-wire (PNP) 12 V 2-wire Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit Grommet 5 V, 12 V 24 V Diagnostic indication (2-color indication) 2-wire 12 V 3-wire (NPN) 3-wire (PNP) IC circuit With timer 5 V, 12 V Lead wire length symbols: 0.5 mNil (Example) E76A 3 mL (Example) E76AL 5 mZ (Example) M5NTZ Solid state switches marked with are produced upon receipt of order.
-wire (PNP) 12 V 2-wire Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit Grommet 5 V, 12 V 24 V Diagnostic indication (2-color indication) 2-wire 12 V 3-wire (NPN) 3-wire (PNP) IC circuit With timer 5 V, 12 V Lead wire length symbols: 0.5 mNil (Example) E76A 3 mL (Example) E76AL 5 mZ (Example) M5NTZ Solid state switches marked with are produced upon receipt of order.
900 1000 700 600 500 400 300 200 100 0 E 800 900 1000 700 600 500 400 300 200 100 0 F 800 900 1000 700 600 500 400 300 200 100 0 G When the cylinder is extended, the speed controller is metered-out, is connected with the cylinder directly, and its needle is fully open.
light 8 3.2 DC (+) Brown 2.6 2 4.6 4 2.7 4 2.8 Most sensitive position 6 2.8 22 500 (3000) 20 2.7 OUT Black 3.2 2.6 DC () Blue 9.5 6 Most sensitive position 22 500 (3000) 4 D-M9B, D-M9BV Precautions OUT (+) Brown Be sure to read before handling.
Indicator light DC (+) Brown 8 3.2 2.6 2 4.6 4 2.7 4 2.8 Most sensitive position 6 2.8 22 500 (3000) 20 2.7 OUT Black 3.2 DC () Blue 2.6 9.5 6 Most sensitive position 22 500 (3000) 4 D-M9B, D-M9BV OUT (+) Brown Precautions Be sure to read before handling.
1000/2000 1000/5000 500/2000 200/1000 100/500 100/200 *Dimension A reference after installation.
W W 1 1 W W 2 2 1 1 11 11 12 12 1 32 - 73 () 12 1. CW [CW] 2. CCW [CCW] 12 1. [] 2.
S [S ] 2.S [S ] S S 1 () (0 ) (+) (+) 1 + mm (-) (-) 1 mm 1 mm/s 1 mm/s 2 1 INP mm 1 31 - mm 0mm M (0mm) 100mm 1 M (100mm) (+)(-) 1 1 +(++) 12 2 (+) SW SW SW 12 1. 2. W W 1 1 W W 2 2 1 1 11 11 12 12 1 32 - 7.3 () 12 1.CW [CW] 2.CCW [CCW] 12 1. [] 2.
XLA XLFV/With solenoid valve J XL XL XLQ XM XY M N Port P D(Pressure port) XSA K L P R XVD XGT Port R (Exhaust port) CYV (mm) (mm) J J K L M N K L M N Model XLFV-16 XLFV-25 XLFV-40 XLFV-50 Model XLFV-63 XLFV-80 XLFV-100 XLFV-160 35.5 12.3 10.2 3.6 3.6 78.5 28.7 12 4 2 40.5 13.8 10.2 3.6 3.6 87 38.7 12 4 2 50.5 21.6 10.2 3.6 3.6 105.5 49.7 12 4 2 67 21.7 12 4 2 128.5 58 12 4 2 Other dimensions
AWD ITV Wiring diagram Current signal type Voltage signal type VBA Brown Brown VE Blue Blue Vs Vs White White VY Black Black A Vin G 24V DC 12 to 15V DC 4 to 20mA DC 0 to 20mA DC Vs: Power supply Vs: Power supply 24V DC 12 to 15V DC 0 to 5V DC 0 to 10V DC AL Vin: Input signal A : Input signal Preset input type Brown Blue S1 White Vs Black S2 Vs: Power supply 24V DC 12 to 15V DC One of the
Reed switch Solid state switch Relay, PLC 100 V, 200 V Yes Connector Terminal conduit DIN terminal Grommet 12 V 2-wire 24 V PLC Relay, PLC 100 V, 200 V Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC circuit Grommet 2-wire 12 V Connector IC circuit 3-wire (NPN) 2-wire Terminal conduit 5 V, 12 V Relay, PLC Yes 24 V 12 V 3-wire (NPN) 3-wire (PNP)
Applicable cylinder bore size Metal stopper 6 8 12 16 20 25 6 8 12 16 20 25 3 Air Slide Table Series MXQ Shock Absorber Specifications Table Accuracy RB0805 RB0806 RB1007 RB1411 RB1412 Shock absorber model MXQ8 MXQ12 MXQ16 MXQ20 MXQ25 B C Applicable slide table Radial internal clearance 19.6 14.7 5.88 2.94 0.98 Max. absorbed energy J 12 11 7 6 5 Stroke absorption mm M 50 to 500 Max. impact
500] 500 L/min(PFMC7102) 29 [F 1] [ 1000] 1000 L/min(PFMC7202) [ 25] 25 L/min(PFMC7501) [ H_1] OUT1 [ 50] 50 L/min(PFMC7102) [ 100] 100 L/min(PFMC7202) [ CoL] OUT1 [SoG] ONOFF [ oU2] OUT2 2 [ HYS] [ 2ot] OUT2 2 [ 2_P] [ 250] 250 L/min(PFMC7501) [ P_2] OUT2 2 [ 500] 500 L/min(PFMC7102) 37 [F 2] [ 1000] 1000 L/min(PFMC7202) [ 25] 25 L/min(PFMC7501) [ H_2] OUT2 2 [ 50] 50 L/min(PFMC7102) [
Lead Series Lead (Including Pn20E Pn210 symbol pulley ratio) A 12 65536 750 LEY25/LEYG25 B 6 375 LEY25D/LEYG25D C 3 131072 375 A 20 65536 1250 LEY32/LEYG32 B 10 625 LEY63D C 5 131072 625 A 16 1000 LEY B 8 500 LEY32D/LEYG32D C 4 250 65536 A 20 1250 B 10 625 C 5 131072 625 LEY63 5(2.86) L 229376 625 (Pulley ratio 4/7) H 20 1250 LEFS25 A 12 750 B 6 375 H 24 1500 LEFS32 A 16 1000 B 8 500 LEF