Conformed standard JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 Cable length Connector model Impact resistance 300 m/s2 S M L A B D 0.5 m 1.0 m 3.0 m M83 pin M84 pin M124 pin Enclosure IP-67 (IEC529 standard) Insulation resistance 100 M or more at 500 M VDC Note) Type D is available for the D-P5DW type only. Note) L is available for the D-P5DW type only.
M L H A M W E LQ1H11-M LQ1H12-M LQ1H21-M LQ1H22-M LQ1H23-M LQ1H24-M LQ1H31-M LQ1H32-M LQ1H33-M LQ1H34-M LQ1H35-M LQ1H36-M LQ1H41-M LQ1H42-M LQ1H43-M LQ1H44-M LQ1H51-M LQ1H52-M LQ1H53-M LQ1H54-M LQ1H61-M LQ1H62-M LQ1H63-M LQ1H64-M 4 3 6 4 6 4 10 8 6 10 8 6 12 10 12 10 19 12 19 12 25 19 25 19 1/8 21 1/8" 25 10 11.5 10 Class 1 31.5 1/8" 15 35 16.5 14 14 H (A) L 29 1/4" W M 36.5 1/4" 20 42.5
Cooling capacity correction coefficient: Coefficient to calculate the cooling capacity at each altitude At an altitude of 1800 meters = Cooling capacity 8.4 x 0.8. Altitude [m] 1. Max. ambient 2. Cooling capacity temp.
Cooling capacity correction coefficient: Coefficient to calculate the cooling capacity at each altitude At an altitude of 1800 meters = Cooling capacity 8.4 x 0.8. Altitude [m] 1. Max. ambient 2. Cooling capacity temp.
40K Note 1) Optional parts are not assembled and are supplied loose at the time of shipment (except for option E).
Cooling capacity correction coefficient: Coefficient to calculate the cooling capacity at each altitude At an altitude of 1800 meters = Cooling capacity 8.4 x 0.8. Altitude [m] 1. Max. ambient 2. Cooling capacity temp.
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 04 (1/2), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None, Calibration Certificate: None, Made to Order
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 04 (1/2), Output Specification: L (Out 1: IO-Link: Switch Output, N/P, Out 2: None; Temperature Sensor ), Temperature Sensor: T (Temperature Sensor), Lead Wire: Q (w/M12-M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: None
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 1/2, Output Specification: OUT1: NPN; OUT2: Analog 4 to 20mA, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 1/2, Output Specification: Out 1: IO-Link: Switch Output, N/P, Out 2: None; Temperature Sensor , Temperature Sensor: Temperature Sensor, Lead Wire: w/M12-M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate
Where the wiring length to load is greater than 5 m. Where the load voltage is 100 VAC. The contact life may be shortened. (Due to permanent energizing conditions.) L D-M9P (Example) Nil Lead wire length 0.5 m 3 m L 5 m Z Note 1) Applicable auto switch with 5 m lead wire Z Solid state switch: Manufactured upon receipt of order as standard.
Lead wire length symbols: 0.5 m Nil (Example) M9NW Solid state auto switches marked with v are produced upon receipt of order. 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ For details about auto switches with pre-wired connector, refer to the WEB catalog or Best Pneumatics.
'nstall with at least 60mm of free space below ~ "5 0 the unit to allow easy access. '3 02 t0 ~ OTightening torque of mounting screw (M3) for 0.1 I' gauge and blanking plate is 3 ~ 5 kgf' cm. 0. 15 O~ 0.2 0.3 0.4 0.5 0.6 0.7 0 8 0.9 1 Inlet pressure MPa 00 1000 2000 3000 Flow rale Q/ min iANRi Cautions on Use AR4001 04 AR4001-04 .When the primary pressure has been released, 0.6 I'-r-. the
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed above, refer to page 23 for details. For details about auto switches with pre-wired connector, refer to the Best Pneumatics No. 3. For the D-P3DWA, refer to the WEB catalog.
VSA4230-02 VSA4230-03 VSA4230-04 VSA4330-02 VSA4330-03 VSA4330-04 VSA4430-02 VSA4430-03 VSA4430-04 2 position single VA 3 8 1 8 Rc 0.75 1 8 Rc 1 8 Rc SA 2 position double 3 8 1 8 Rc 0.86 1 8 Rc VA 1 8 Rc 3 position closed center 3 8 1 8 Rc 0.90 VM 1 8 Rc Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (
L3 L1 T L2 ASG32F-01 ASG42F-02 ASG52F-03 ASG62F-04 H (Width across flats) L4 Applicable tubing O.D. d L6 A D L5 M T L1 L3 L2 Max.
The total number of solenoids (points) must not exceed 24. 1.5 m 3 m 5 m Cannot be used for transfer wiring. Lengths other than the above is also available.
TMH ASD AS Maximum return speed (mm/s) 100 200 300 Speed Controller Cylinder Solenoid valve Tubing Silencer AS-FE 6 ASD230FG CJ2 SYJ500 TU0604 1 m AN11001 KE 10 16 Cylinder size AS-FG AS-FG 20 ASD330FG CM2 SYJ700 TU0604 1 m AN11001 Cylinder size 25 AS-FP 32 Values at 0.5 MPa and 20C.
-04 KPGY04-M5 KPGY04-01 KPGY04-02 KPGY06-M5 KPGY06-01 KPGY06-02 KPGY08-01 KPGY08-02 KPGY10-02 KPGY10-03 KPGY12-03 KPGY12-04 M5 1/8 1/4 M5 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 8 10 14 8 10 14 12 14 8 15.3 22 26 15.8 23.2 27.2 24.4 28.4 29.9 31.9 33.1 37.1 32.5 36.5 40.5 35 40 44 44.5 48.5 53.5 55 58 60.5 6 13 19 7 14 20 14 22 29 39 41 68 4 4 4 18 20.7 10.4 D1 10 M M L1 8 L2 A 6 D1 10 10 19.5 22.8
(The SI unit is provided for use in Japan.) *9 v: For pipe thread type: NPT only *10 : Select with options: E1, E2, E3, E4. *1 Set the inlet pressure to at least 0.05 MPa higher than the set pressure. *2 Options B, G, H, M are not assembled and supplied loose at the time of shipment. *3 Assembly of a bracket and set nuts (applicable to the AR20(K)-B to AR40(K)-B).