The solenoid must be connected to a safety barrier located in a non-hazardous area.
Therefore, do not use a cylinder without a bumper bolt. Furthermore, if the bumper bolt is tightened without a nut, the piston seal is caught in the leveled part, damaging the seal. 3. A bumper at the end of the bumper bolt is replaceable. In case a missing bumper, or a bumper has a permanent settling, use a following part numbers for ordering.
A + A' A' w After piston seal H has passed air passage A, air is exhausted only through A'. The section marked with slanted lines becomes a cushion chamber, and an air cushion effect is achieved. A A' A' e When air is supplied for the piston extension, the check valve opens and the piston extends with no delay.
Dont use a wrench on push-to-connect end. 2 2 Cut tubing square with a clean 90 edge Dont use excessive tube angle cut which can lead to leakage or breaking. 90 90 3 3 Use SMC Tube Cutters Dont use dikes, a knife, a saw or a dull tool to cut the tubing.
D-F9WV D-F8 Model A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E 18.5 31 6.5 20.5 41 8.5 20.5 33 4.5 17 20.5 31 4.5 15 20.5 41 4.5 15 20.5 51 4.5 35 22.5 43 6.5 27 22.5 33 6.5 17 22.5 43 6.5 27 22.5 53 6.5 37 MIW12-12D MIW20-20D 6 4 4 2 18.5 29 6.5 20.5 31 8.5 MIS12-10D MIS20-10D 4 2 6 4 2.5 4 18.5 39 6.5 20.5 41 8.5 MIS12-20D MIS20-20D 6 4
A B C A B A B A B A B 15A 20A 25A Note 1) For each piping diameter for each body size, the second and later numbers or symbols indicate reducing.
Double acting PA PA B A PB B A With by-pass Suck back valve Manual Operation-Series LVH N.C. Double acting P PA PA Locking and non-locking types available B A B A PB B A Integral fitting type/Threaded type Manifolds Main applications and fields For shut off For air bleeding N.C.
[Check valve] A check valve is a safety device intended to prevent reverse flow. The AP 64 is a unique design with only one moving part in the gas stream, an O-ring. It is a springless design, free of springs and poppets. [Vacuum generator] A venturi device that creates vacuum by flowing gas through a nozzle.
When a surge generating a load such as a relay or solenoid is directly driven, use a type of switch with a built-in surge absorbing element. 4. Since the type of fluid varies depending on the product, be sure to verify the specifications. The switches do not have an explosion proof rating. To prevent a possible fire hazard, do not use with flammable gases or fluids. 5.
A slit panel and a panel without slit are used in combination. Refer to the operation manual for details.
A CAT.ES100-43 A For General Fluids High Precision Digital Pressure Switch F/ISE ZSE 50 60 50 60 Series High precision/High resolution pressure switch. Applicable for pressure detection with a wide range of fluids, by using a stainless steel diaphragm. Pressure detection for a wide range of fluids.
Cover Rod cover Unit holding tie-rod A (2 depth 1 mm hole is on the side of tie-rod for attaching unit A.)
Do not use a load that generates surge voltage.
If there is a risk of contact, provide safety measures such as a cover or a system that uses sensors that will activate an emergency stop before contact is made. 2. Use a balance circuit in which lurching of the piston is taken into consideration.
After tightening by hand, tighten an additional 1/4 rotation for M3 and 1/6 rotation for M5 with a tool. However, when using a miniature fitting, tighten an additional 1/4 rotation with a tool after tightening by hand. Also, when there are 2 gaskets such as in case of a universal elbow or universal tee, tighten an additional 1/2 rotation.
When a surge generating load such as a relay or solenoid is directly driven, use a type of switch with a built-in surge absorbing element. 4. Since the type of applicable fluid varies depending on the product, be sure to verify the specifications. The switches do not have an explosion proof rating. To prevent a possible fire hazard, do not use with flammable gases or fluids. 5.
A A B (mm) D-A9V D-A9 D-M9 D-M9W D-M9V D-M9WV A B A B Bore size (mm) W Hs A B W A B Hs 32 40 50 63 12 [17] 9 1 12 [17] 9 29 8 [13] 5 3 (0.5) 8 [13] 5 27 16 11.5 1.5 16 11.5 32.5 12 7.5 5.5 (3) 12 7.5 30.5 14 <19> 14.5 4.5 14 <19> 14.5 42 10 <15> 10.5 8.5 (6) 10 <15> 10.5 36.5 16.5 17.5 7.5 16.5 17.5 42 12.5 13.5 11.5 (9) 12.5 13.5 40 [ ]: Values for 5 mm stroke with 32 < >: Values for 10