Air Management System, AIR MANAGEMENT SYSTEM, Q22, 1.80000 lb
Air Management System, AIR MANAGEMENT SYSTEM, Q22, 1.80000 lb
Air Management System, AIR MANAGEMENT SYSTEM, Q22, 1.80000 lb
Air Management System, AIR MANAGEMENT SYSTEM, Q22, 1.80000 lb
Air Management System, AIR MANAGEMENT SYSTEM, Q22, 1.80000 lb
Air Management System, AIR MANAGEMENT SYSTEM, Q22, 1.80000 lb
Air Management System, AIR MANAGEMENT SYSTEM, Q22, 1.80000 lb
Air Management System, AIR MANAGEMENT SYSTEM, Q22, 1.80000 lb
Air Management System, AIR MANAGEMENT SYSTEM, Q22, 1.80000 lb
Air Management System, AIR MANAGEMENT SYSTEM, Q22, 1.80000 lb
Air Management System, AIR MANAGEMENT SYSTEM, Q22, 1.80000 lb
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: F (G), Port Size: 03 (3/8), Normally Open, Closed: C (N.C., Normally Closed), Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: G (Non-locking Push Type), Made to Order Option: X102 (Hub and Relief Valve only)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: N (NPT), Port Size: 04 (1/2), Normally Open, Closed: C (N.C., Normally Closed), Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X102 (Hub and Relief Valve
EN 60079-0: 2012 EN 60079-11: 2012 EN 60079-26: 2007 EN 60079-31: 2009 EN 60079-0: 2012 EN 60079-11: 2012 EN 60079-15: 2010 EN 60079-31: 2009 II 3 G Ex nA IIC T6...T4 Gc II 3 D Ex tc IIIC T90 C Dc Input: Ui 30 V, Ii 152 mA Output: Ui 30 V, Ii 152 mA II 3 G Ex ic IIC T6...T4 Gc II 3 D Ex tc IIIC T90 C Dc Input: Ui 30 V, Ii 152 mA, Pmax = device limits itself, Ci 22 nF, Li 53 H.
EU2006/66/EC20[] Hg:(0.0005%), Cd:(0.002%), Pb:(0.004%) / 4 4.1 (IEC/EN 61800-5-2 ) STO(IEC/EN 61800-5-2: 2007 4.2.2.2 STO) LECSS2-TSTOSTO 4.2 4 4.2.1 LECSS2-T () 4.1.2 LECSS2-T ISO/EN ISO 13849-1 3 PL dIEC/EN 62061 SIL CL 2IEC/EN 61800-5-2 SIL 2 (STO) IEC/EN 61800-5-1IEC/EN 61800-3IEC/EN 60204-1 LECSS2-TMR-J3-D05()PLCs 4.1.3 LECSS2-T() 15 (1) (a) 75/60[AWG] 75/60 [AWG](1) L11L21
DIN terminal type "Y" conforming to EN-175301-803C (former DIN43650C) is also available. For details, refer to page 482. For connector cable of M8 connector, refer to page 490.
Table 4-1 EX245 24 V DC +20% -15% 1ms IP65 () (IEC60529) 10M -FE 500VAC IEC61131-2 500VAC1 -FE IEC61131-2 -10 to 50 -20 to 60 35%85% RH 80 kPa 108 kPa ( 2000 m ) 66 kPa 108 kPa ( 3500 m ) 10 Hz to 57 Hz 0.75 mm 57 Hz to 150 Hz 49 m/s 2 XYZ 2 XYZ 3 EN 60068-2-27/29 EMC , 2014/30/EU, IEC61326-3-1 , 2006/42/EC, EN 62061, EN ISO 13849 TUV , EN 61508, EN 62061, EN ISO 13849
ldbF k pcd by 6 Edd h with integral with integral vacuumgauge digitalswitch 56 IllL $en ) Schematic Symbol NZLr12-EE NZLl12 NZLl12-Efl s1.2mm 100!
Y type is a DIN terminal conforming to EN-175301-803C (former DIN43650C). Refer to page 173 for details. Setting -5LOU is available only for connector box type. Refer to page 176 for connector cable of M8 connector. M8 connector conforming to IEC60947-5-2 standard is also available. Refer to page 168 for details.
&id=T-E" target="_blank">T-X64 and TH-X64
Nylon tubing with designated numbers printed on it: T-X190
2/3-core polyurethane coil tubing (change of color):
https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=tubing&fa_id=11114