75 100 125 90 102 115 140 165 12.5 54 67 79 92 117 142 167 190 With Rod Boot With Air Cushion Built-in One-touch Fittings Symbol Q P N1 WB G ZZ Bore size (mm) WA Bore size (mm) Stroke Bore size (mm) 20 20 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 21.5 6 8.5 8 13 17.5 20 25 25 158 171 183 196 221 246 271 24.5 6 10.5 8 13 17.5 25 32 32 162 175 187 200 225 250 275

48 68 33.5 7 21 54 68 55 153.5 70 53 23.5 27.5 48.5 55 35 59 85.5 42.5 Dimensions by the Number of Stations Manifold stations 10 Model Symbol 9 8 7 6 5 4 3 2 L1 454 412 370 328 286 244 202 160 118 ARM2500 L2 442 400 358 316 274 232 190 148 106 L3 420 378 336 294 252 210 168 126 84 L1 592 537 482 427 372 317 262 207 152 ARM3000 L2 578 523 468 413 358 303 248 193 138 L3 550 495 440 385 330 275

MPa) Bore size (mm) 5 Bore size (mm) direction 0.3 75 50 45 40 0.7 35 30 0.5 25 20 15 10 100 12 59 60 42 54 47 25 41 35 29 IN 12 16 79 84 57 76 67 34 59 50 42 OUT 20 178 165 152 106 140 127 75 114 101 45 88 75 63 IN 16 25 216 202 187 141 173 158 101 144 129 60 115 100 86 OUT 32 471 318 297 277 165 256 235 118 214 193 71 173 152 131 IN 576 20 40 597 413 390 367 220 344 321 157 298 275

Load Center Offset in Operating Direction (Lo) 25 144 9 + Lo 32 275 11 + Lo 40 520 13 + Lo Bore size (mm) Allowable load weight (WA) (kg) Bore size (mm) Allowable load weight (WA) (kg) 2 Lo + 1.7 6 5.6 Lo + 2.8 13.34 Lo + 2.9 10 Lo: Distance from center of slide block to load's center of gravity (cm) 15 43.2 Lo + 6 20 46.15 Lo + 3.55 25 80 Lo + 4 32 188.1 Lo + 5.7 40 8-15-63 63 Series CY1L

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber bumper (standard), Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 275, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number

Stroke end] Stroke end Note 3) [Origin] M D K Note 4) A + Stroke W B + Stroke Stroke L U 4 x O1 thread depth R FH EH M 6 x MO thread depth MR XA H9 depth XA MH Section XX details MA ML + Stroke MC MD Section XX XB XA H9 XA [mm] Size Stroke range [mm] A B C D EH EV FH FV G H J K L Without lock With lock 25 15 to 100 250 300 89.5 13 20 44 45.5 57.6 57.7 94.7 M8 x 1.25 24 17 14.5 101 to 400 275