SMC Corporation of America
Elite Part Number Search
Search Results "CDJP2B10-15D-B-A90"

Order the seal kit, based on each bore size. 8-7-20 21 Long Stroke Slide Table Series MXW Proper Auto Switch Mounting Position (Detection at stroke end) Reed Switch: D-A90(V), D-A93(V), D-A96(V) Stroke (mm) Model 25 50 75 100 125 150 175 200 225 250 275 300 A 52.5 31.5 27.5 27.5 27.5 27.5 B 79.5 100.5 125.5 150.5 175.5 200.5 MXW8 B A W 32.5 11.5 7.5 7.5 7.5 7.5 V 99.5 120.5 145.5 170.5 195.5

11.5 18.5 23 B 12.5 14.5 13.5 19 B 9 11 10 15.5 B 7 9 8 13.5 A 14 12 19 23.5 B 13 15 14 19.5 A 14.5 12.5 19.5 24 B 13.5 15.5 14.5 20 B 7.5 9.5 8.5 14 B 10.5 12.5 11.5 17 B 7 9 8 13.5 20 25 32 40 Note) When setting an auto switch, be sure to check its operation before adjusting.

Bore size (mm) A B Hs Ht Hs Ht 125 1.5 1.5 69.5 71 69.5 69 140 1.5 1.5 76 77 76 76 160 1.5 1.5 85 88.5 85 85 180 7 5 95 97.5 95 95 200 9.5 7.5 106 108 106 106 9-9-22 23 Auto Switch Specifications Series CLS Proper Auto Switch Mounting Position for Lock Unit Auto switch Auto switch model D-M9N D-M9P D-M9B D-A90 D-A93 SMC CLS125 MODEL b a b a b Bore size (mm) 125 140 160 180 200 250 a 59 39

D-A7lH, A80H D-A73C, A80C D-F7l, J79 D-F7lV, J79C D-A79W D-F9l D-F9lV D-F9lWV D-F9lW D-F9BAL D-P5DW D-A9l D-A9lV D-A7, A8 Model B 6.5 7 6 8.5 11.5 14.5 A 28.5 29 33 24 28.5 28.5 B 7 7.5 6.5 9 12 15 B 4 4.5 3.5 6 9 12 B 11 11.5 10.5 13 16 19 B 4.5 7.5 10.5 B 5 7.5 10.5 13.5 B 9 11.5 14.5 17.5 A 34.5 25.5 30 30 B 8 10.5 13.5 16.5 A 19.5 24 24 A 28 28.5 32.5 23.5 28 28 A 25.5 26 30 21

7 7 8 B 6 6 7 B 3 3 4 0 to 1 A B 20 25 32 D-Z7/Z80 D-Y59/Y69/Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL A 23 23 32 37 Bore size (mm) B 0 0 0 4 40 50 63 80 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Minimum Stroke for Mounting Operating Range Bore size (mm) Bore size (mm) Auto

D-H7W D-H7NF D-H7BA D-C7/C8 D-H7 D-H7C D-H7W D-H7BA D-H7NF D-G5/K5 D-G5W D-K59W D-B5/B6 D-B59W D-G5NT D-G59F D-H7C D-G5BA D-M9V D-M9WV D-M9AV D-A9V D-C7/C8 D-C73C D-C80C D-M9(V) D-M9W(V) D-M9A(V) D-C73C D-C80C D-B5 D-B6 D-B59W D-A9(V) A B A B A B A B A B A A B B 28.5 29 30.5 31 42.5 42.5 Hs 25.5 28 31.5 36 41.5 48.5 Hs 24.5 27 30.5 35 40.5 47.5 Hs 27 29.5 33 37.5 43 50 Hs 27.5 30

Auto Switch Proper Mounting Position for Stroke End Detection MY1CW 16, 20 MY1MW 16, 20 B A Reed switch D-A90(V), D-A93(V), D-A96(V) Solid state switch D-F9N(V), D-F9P(V), D-F9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) Mounting position 20 16 20 16 20 Mounting position Mounting position 16 A 90 70 93 73 94 A A 74 B 110 90 107 87 106 B B 86 Operating range Note) 7.5 11 6.5 8.5 6.5 Operating range

B Reverse the mounting direction A Reed switch D-A90(V), D-A93(V), D-A96(A) mm Auto switch mounting Switch operating range Stroke (mm) 20 45 25 51 31 Type 25 50.5 30.5 30 59 39 10 35 15 40.5 20.5 Caution A B A B A B MXP10 Tool for auto switch mounting MXP12 5 Use the screwdriver with grip diameter 5 to 6 mm when set screw (attached to auto switch) is set.

Nil M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 TF G 1/8 G 1/8 G 1/8 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 b C H B d M10 x 1.0 M20 x 1.5 M26 x 1.5 M32 x 2.0 H 4 8 8 10 B 14 26 32 41 C 16.2 30 37 47.3 Part No.

(V), D-A93(V), D-A96(V) (mm) Lead wire entries outside A A Model Mounting Switch operating range A B A B A B 54 MXY6 34 59 5 MXY8 MX 39 67 MXY12 MTS 47 MY Solid State Switch D-M9B(V), D-M9N(V), D-M9P(V) Lead wire entries inside (mm) B B CY Model Mounting Switch operating range A B A B A B 50 MXY6 2 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main

8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4.

Round plate (Including column) Position of rotational axis: Through the center axis (B) Number of teetha 1. Find the moment of inertia I for the rotation of shaft (B). B r 2. I is converted to the rotation of the shaft (A). B 2 r I = m2 2 b a I I = A B Number of teethb 5.

Proper Auto Switch Mounting Position (Detection at stroke end) C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Series MY2C Series MY2H Series MY2HT (mm) D-M9, D-M9V (mm) D-M9, D-M9V (mm) D-M9, D-M9V A A A B B B Bore size 16 25 40 Operating range Bore size

30 40 13 XL-OMY0002 8 X L D 25 M9N A A ( X A N1 A ) 25 40 B A 50 63 80 C P11 160 100 FKM() P8 KF (NW) D K (DN) () A / A F G A J B K C L M M9N D-M9N M9P D-M9P / 560 M9B D-M9B A90 D-A90 H0 H4 H5 5150 100 A93 D-A93 120 M9// 25H4 14 XL-OMY0002 9. 200 2580 100 100,160 [] 1 1.5 1 XLD-25,XLD-40,XLD-50,XLD-63,XLD-80 200 XLD-100,XLD-160 100 : FKM 110 Pa <> 15 XL-OMY0002

Auto switch a b d c Proper mounting positions (mm) A B Bore size (mm) 63 80 100 10 13 17.5 14 18.5 23.5 Proper mounting positions (mm) a b 14 18 17 c 20 24 23 d D-A9 type D-F9 type D-F9 W type 2 6 5 8 12 11 In order that adjacent switches do not misoperate, they should be set within 1mm of the proper mounting positions indicated in the table above.

) 1/200.04mm/90 () (4) 4 ,0.01mm 5-3 CEP1 A /B 90 11 12 11 10 10 ,A ,90,B ,B ,90,A , ,A B 6 6-1 ?

Auto switch groove positions (mm) B 6.9 8.8 13.7 17.1 A 10 14 19 26 Bore size (mm) 6 10 16 20 4-4.2 Auto switch mounting groove B A 38

How to determine the auto switch installation position MHZ2 Step 2) Insert auto switch into the switch installation groove from direction B. "Set up as directed with power connected under no pressure or low pressure." A B MHZJ2 MHQ Step 3) Slide the auto switch in the direction of the arrow until the light illuminates.

Magnet: D (Built-in Magnet), Bore Size: 10, Port Thread: Bore: 6, 10, 16, 20, 25, M5x0.8 ; Bore: ø32, Rc1/8, Stroke: 15mm, Auto Switch: A90--Reed, AC Volt, Horizontal