Refer to page 378 for minimum stroke with auto switch. 32 is for B-series rod size only. CH2 H B B 50 100 CH D2 H B B 50 100 M9BW With Auto Switch With auto switch (built-in magnet) Port and cushion valve positions Refer to page 359.
C B A stroke A C 3) 2nd stage: B-A stroke operation Following the 1st stage, when the air pressure is supplied from the C port, the rod operates the B-A stroke. B B-A stroke B A C 4) Cylinder retraction When the air pressure is supplied from the B port, the rod retracts completely. B stroke A stroke A stroke or B stroke operation can be made individually.
Hs Auto switch 12 D-B5/B6 15 22.5 A B 33 410 Auto Switch Mounting CHA Series Auto Switch Proper Mounting Positions (mm) D-G5/K59 D-G5W/K59W D-G59F/G5BA D-G5NT D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-F5/J59 D-F5W/J59W D-F59F/F5BA D-F5NT D-G39/K39D-A9/A9V D-A5/A6 D-A59W D-B5/B64 D-B59W D-A3/A44 Bore size (mm) CHQ A B A B A B A B A B A B A B A B A B A B A B CHK 40 20.5 21.5 17 18 22 23 12.5 13.5 10.5
CRQ2X MSQX MRQ Auto Switch Working Principle [Pressure is applied from the B port.] The auto switch B is turned ON by the magnet B in the state that the pressure is applied from the B port and the piston B moves to the left side. At this time, the auto switch A turns OFF . Magnet B Piston B A port B port Auto switch B Auto switch A [Pressure is applied from the A port.]
C A B C A B C A B C A B C A B C LEY40 1100 Work load [kg] 1 1.5 3 2.5 5 10 4.5 9 18 7 14 28 1 1.5 3 1.2 2.5 5 Lead 4: LEY40C 800 900 1000 Pushing force 85% 65% 85% 65% 95% 95% Lead 8: LEY40B Lead 16: LEY40A 10 20 30 40 50 60 70 80 90 0 100 200 300 400 500 600 700 Force [N] Non-rotating Accuracy of Rod Size Non-rotating accuracy q 16 1.1 25 0.8 32 0.7 40 + Max. 65% Set value of pushing force
Next, B is entered to find A the inertial moment for the rotation of shaft (A) as 5 b a A = ( ) 2 B Number of teeth = b Kinetic Energy/Rotation Time Even in cases where the torque required for rotation of the load is small, damage to internal parts may result from the inertial force of the load.
Low Speed Cylinder Double Acting, Single Rod Series CQSX 12, 16, 20, 25 How to Order CQSX D B 20 30 Without auto switch 30 F9BW B 20 CDQSX D With auto switch Number of auto switches Built-in magnet 2 pcs. 1 pc. n pcs.
Example Rail mounting style CDJ2XB10-45-A Band mounting style CDJ2XB16-60-B Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø4 mm, Stroke: 10 mm, Rod End Thread: With Thread, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, 0.5M, Lead Wire or Prewired Connector: Z (5m)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø4 mm, Stroke: 10 mm, Rod End Thread: With Thread, Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical, 0.5M, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø4 mm, Stroke: 10 mm, Rod End Thread: With Thread, Auto Switch: M9PA--Solid State, Water Resist., 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: M (1m)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø4 mm, Stroke: 10 mm, Rod End Thread: With Thread, Auto Switch: M9PAV--Solid State, Water Resist., 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: M (1m)
Cylinder (Tube) Inner Diameter(φ): 4, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet, Auto Switches: M9B, Lead
Cylinder (Tube) Inner Diameter(φ): 4, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet, Auto Switches: M9B, Lead
Cylinder (Tube) Inner Diameter(φ): 4, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet, Auto Switches: M9B, Lead
Cylinder (Tube) Inner Diameter(φ): 4, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet, Auto Switches: M9BV,
Cylinder (Tube) Inner Diameter(φ): 4, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet, Auto Switches: M9BWV,
Cylinder (Tube) Inner Diameter(φ): 4, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet, Auto Switches: M9P, Lead
Cylinder (Tube) Inner Diameter(φ): 4, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet, Auto Switches: M9P, Lead
Cylinder (Tube) Inner Diameter(φ): 4, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 0.7, Specification: Built-in magnet, Auto Switches: M9PV, Lead