F 3/32 2.4 1/8 1/8 3.2 D 200 VAC 3/32 2.4 E 230 VAC 1/8 3.2 1/4 F 24 VDC C37 5/32 4 G DIN terminal 24 VDC G 7/32 5.6 With surge voltage suppressor J 1/8 3.2 H 100 VAC K L P Q R S T U 5/32 3/8 4 J 110 VAC 7/32 5.6 2 Size 2 Single K 200 VAC Unit 3/32 2.4 1/8 N.C.
Dimensions A, DB, E: MLGPL (Ball bushing bearing) Dimensions A, DB, E: MLGPM (Slide bearing) A E A E Bore size (mm) 131 141.5 144.5 Bore size (mm) 115 128 131 DB DB st 50 50 < st 200 200 < st 350 200 < st 350 20 25 25 st 50 50 < st 200 74 89 84 st 50 50 < st 100 100 < st 200 200 < st 350 16 20 20 st 50 50 < st 100 100 < st 200 200 < st 350 74 89 84 40 50 63 40 50 63 31 34.5
Dimensions A, DB, E: MLGPL (Ball bushing bearing) Dimensions A, DB, E: MLGPM (Slide bearing) A E A E Bore size (mm) 131 141.5 144.5 Bore size (mm) 115 128 131 DB DB st 50 50 < st 200 200 < st 350 200 < st 350 20 25 25 st 50 50 < st 200 74 89 84 st 50 50 < st 100 100 < st 200 200 < st 350 16 20 20 st 50 50 < st 100 100 < st 200 200 < st 350 74 89 84 40 50 63 40 50 63 31 34.5
200 VAC *3 q Facility water temperature: 25C, w Circulating fluid: Tap water, e Circulating fluid flow rate: Rated flow, r Power supply: 200 VAC *4 q Facility water temperature: 25C, w Circulating fluid: Tap water, e Circulating fluid temperature: CH1 20C/CH2 25C, r Circulating fluid flow rate: Rated flow, t Power supply: 200 VAC, y Piping length: Shortest, u Load: Same as the cooling capacity
With rod boot (mm) Symbol Z h l Stroke f e 1 to 50 1 to 50 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 51 to 100 101 to 150 151 to 200 201 to 300 51 to 100 101 to 150 151 to 200 201 to 300 Bore 68 81 93 106 131 12.5 25 37.5 50 75 160 173 185 198 223 17 36 20 72 85 97 110 135 12.5 25 37.5 50 75 164 177 189 202 227 17 36 25 72 85 97 110 135 12.5 25 37.5 50 75 166 179 191 204 229 17 36
): SQ1241 Double (latching): SQ1240 t e q w t e q w SQ1241 SQ1240 (A)(B) (A)(B) 4 2 4 2 5 1 3 5 1 3 (R1) (P)(R2) (R1)(P)(R2) Double (double solenoid): SQ1241D Double (double solenoid): SQ1240D y e e q w y e q w e SQ1240D SQ1241D (A)(B) (A)(B) 4 2 4 2 5 1 3 u 5 1 3 u (R1)(P)(R2) (R1)(P)(R2) 3 position: SQ1 41 3 4 5 3 position: SQ1 40 3 4 5 y e e q y w e e q w u u SQ1540 SQ1440 SQ1340 SQ1541
Yes None (Non-polar) Nil E Note) Note) A combination of Function [N] (Negative common) and [E] is unavailable. Since [E] has no polarity, it can also be used as a negative common.
Electrical entry 24, 12 VDC/ 100, 110, 200, 220 VAC 24, 12, 6, 5, 3 VDC 24, 12, 6, 5, 3 VDC/ 100, 110, 200, 220 VAC Gasket assembly part no.
: 200 VAC Note 5) q Ambient temperature: 32C, w Circulating fluid: Tap water, e Circulating fluid temperature: 20C, r Load: Same as the cooling capacity, t Circulating fluid flow rate: Rated flow, y Power supply: 200 VAC, u Piping length: Shortest Note 6) With the pressure control mode by inverter.
24 46 48 50 172 174 174 4.5 6 6 3 4 4 84 86 88 6 8 8 122 124 124 40 50 63 M10 x 1.5 M10 x 1.5 MLGPL (ball bushing)/Dimensions A, DB, E MLGPM (slide bearing)/Dimensions A, DB, E (mm) (mm) A E A E Bore size (mm) Bore size (mm) DB DB st50 50
24 46 48 50 172 174 174 4.5 6 6 3 4 4 84 86 88 6 8 8 122 124 124 40 50 63 M10 x 1.5 M10 x 1.5 MLGPL (ball bushing)/Dimensions A, DB, E MLGPM (slide bearing)/Dimensions A, DB, E (mm) (mm) A E A E Bore size (mm) Bore size (mm) DB DB st50 50
Deionized water: Electric conductivity 1 mS/cm or higher (Electric resistivity 1 MWcm or lower) Note 3) q Ambient temperature: 90F (32C), w Circulating fluid: Tap water, e Circulating fluid temperature: 68F (20C), r Circulating fluid flow rate: Rated flow, t Power supply: 200 VAC Note 4) q Ambient temperature: 90F (32C), w Circulating fluid: Tap water, e Circulating fluid flow rate: Rated
: 200 VAC Note 5) q Ambient temperature: 32C, w Circulating fluid: Tap water, e Circulating fluid temperature: 20C, r Load: Same as the cooling capacity, t Circulating fluid flow rate: Rated flow, y Power supply: 200 VAC, u Piping length: Shortest Note 6) When circulating fluid outlet port pressure return port pressure = 0.25 MPa.