Inverter pump Triple inverter HRZD HRW 0.6 kW 1.8 kW Water-cooled refrigeration Air-cooled refrigeration HECR 377 [mm] 970 HEC 2.4 kW HEB Triple inverter HRSH090 HED *1 Under the conditions shown on page 128 HEA Cooling capacity 9.5 kW IDH 1080 0.1C Temperature stability (when a load is stable) Set temperature range 5C to 40C W 377 x H 1080 x D 970 mm Compact, Space-saving Low-noise design

1.0 x8 M6 x 1.0 x10 12REA 50/63 0 -0.2 L NA 33 2-Rc, NPT, G 1/4 14 14 E(h8) E(h8) X D I 4-TC 14 14 Effective thread depth R 23 22 K W 23 25 2 4-M8 x 1.25 25 8-Q 14.5 C 0.1 + Effective thread depth 12 Effective thread depth R B S + Stroke 2 ZZ + Stroke Q x R S TC x R Model L 122 110 K 38 32 C 70 60 X ZZ NA E D B 72.2 58.2 I 70 60 W 12-REA63 12-REA50 100 86 66 53 30-0.033 69 55 M10 x 1.5 x

Reduced outgassing Resin materials eliminated Laser marking is employed for the model designation. o u d t g e 2 a c s u s d i Reduction of outgassing due to surface treatment e n o u d t g R e g a 1 c s u s d i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated.

Count AF Supply pressure: 1.0 MPa Pressure Characteristics Flow Characteristics Set pressure: 0.45 MPa AR 1000 1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 900 kPa 900 Output deviation factor (% F .S.) 800 kPa IR 800 0.5 700 kPa Set pressure (kPa) 700 600 kPa

Printed in Japan 1st printing September, 2000 D-SMC.L.A. P-80 (YG) This catalog is printed on recycled paper with concern for the global environment.

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 1000mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 1100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: -, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: F59--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 25mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewied Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewied Connector: -, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: F5P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewied Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 350mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 350mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: F59--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 400mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 400mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: J59W--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewied Connector: -, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 400mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: J59W--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewied Connector: 3m, Number: -

Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: F5P--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewied Connector: 3m, Number: -