Auto Switch Dimensions (mm) 1 in = 25.4 mm D-A90, D-A93, D-A96 D-A90V, D-A93V, D-A96V M2.5 x 4l Slotted set screw 22 Indicator light Type D-A90 without indicator light 6 2 M2.5 x 4l Slotted set screw Contact protection box specifications 2.7 500 (3000) 9.1 5.1 4 CD-P11 CD-P12 Part No.
CG1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Auto Switch Mounting Height (mm) MB D-Z7/Z-80 D-Y59 D-Y7P D-Y7W D-F5, D-J5 D-F59F D-F5W, D-J59W D-F5BAL, D-F5NTL D-A5 D-A6 D-A59W D-A3 D-G39 D-K39 D-Y69 D-Y7PV D-Y7WV Bore size D-Y7BAL D-A44 D-P5DWL MB1 (mm) Ht Hs
double (Reverse pressure): VQ7-6-YZ-D-SC 3 position closed center : VQ7-6-FHG-D-SC exhaust center : VQ7-6-FJG-D-SC pressure center: VQ7-6-FIG-D-SC 145 155 76.5 68.5 68.5 86.5 50 50 50 50 Manual override Manual override 13 (A port) 13 (B port) 13 (A port) 13 (B port) A B A B 38 50 62 38 50 62 B A B A R1 (L 500) Cable with connector R2 P R2 R1 P (L 500) Cable with connector Mounting hole
When this happens, the sum of the load factors () is the total of all such moments. 500 500 500 2.
kg 4.36 (kg) 0.267 (kg/50 st) 500 (st) Calculation: (Example) REAL32-500 RB J D-X 20Data 10-2-37 37 Series REAL Precautions Be sure to read before handling.
15 Auto switch model Bore size (mm) D-A9 A dimension D-M9 B dimension C dimension D dimension D-A9 D-M9 D-A9 D-M9 D-A9 D-M9 21.5 76.5 72.5 56.5 60.5 17.5 15 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 A dimension D-Y5 D-Y6 D-Y7 B dimension C dimension D dimension Auto switch model D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8
/C8 D-H7 A B 12 Hs 14.5 24.5 Auto switch D-B5/B6 D-G5/K5 A B 8.5 Hs 14.5 11 Auto switch D-B7/B8 D-G7/K7 Proper Auto Switch Mounting Position Auto Switch Mounting Height D-G5/K5 D-G5W D-K59W D-G5NTL D-B5/B6 D-B59W D-G5BAL D-G59F D-G5 D-K59 D-G5W D-K59W D-G5NTL D-G5BAL D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-H7C D-H7 D-H7C D-H7NF D-H7W D-H7BAL D-C7/C8 D-H7 D-H7W D-H7NF D-H7BAL D-B7/B8 D-B73C
8 6 D-M9/D-F9W 5 4 D-Z7/Z80 9 9 11 A B D-Y59/Y7P D-Y7W 6 6 6 Switches cannot be mounted in some cases.
A B C D Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) 15 20 25 30 1000 1000 930 740 600 500 Model Note LJ1H202PC-500LJ1H202PC-600LJ1H202PC-700LJ1H202PC-800LJ1H202PC-900LJ1H202PC-1000700 700 600 600 500 500 500 500 500 500 500 500 500 500 500 500 500 500 Power supply: 100/110(V)AC 10% Compatible controller: LC1-1B2H1Power supply: 200/220(V)AC 10% Compatible controller
/J79 D-J79C D-F7V D-F7NTL D-F7W/J79W D-F7WV D-F7BAL D-A7/A80 D-A7H/A80H D-A73C/A80C D-F7LF D-F79F Bore size (mm) B A 10 6 3 4.5 (mm) 15 6 4 4.5 Dimension A Dimension B 20 6 3 4.5 Auto switch model D-A72 D-A72 25 6 3 4.5 D-F7W/J79W D-F7WV D-F7LF Note 1) D-F7W/J79W D-F7WV D-F7LF Note 1) D-F79F D-F7BAL D-A7H/A80H D-A73C/A80C D-F7/J79 D-J79C D-F7V D-A7H/A80H D-A73C/A80C D-F7/J79 D-J79C D-F7V
Note 2) D-Z73, D-Z76, D-Z80 D-F79, D-F7P, D-J79 D-F7NV, D-F7PV, D-F7BV D-J79C D-F79W, D-F7PW, D-J79W D-F7NWV, D-F7BWV Note 1) D-F9N, D-F9P, D-F9B Note 2) D-Y59A, D-Y7P, D-Y59B D-Y69A, D-Y7PV, D-Y69B Note 2) D-Y7NW, D-Y7PW, D-Y7BW D-Y7NWV, D-Y7PWV, D-Y7BWV D-F7BA D-F7NT D-F79F D-F7LF Note 1) Indicates auto switches for CY1R6 to 20.
to 500 kPa 50 to 500 kPa A sensor may be unconnected or miswired.
660 320 500 660 500 660 500 660 500 660 500 660 7.9 0.33 3.0 1 4 (8A) 15 0.61 4.5 4.5 15 0.61 3.0 1 4 (8A) 6 1.1 6 26 26 1.1 3 1.6 8 38 7.9 0.33 1.0 3 8 (10) 4.5 1.9 10 46 15 0.61 6 0.33 3 7.9 26 1.1 Note) Weight of grommet type.
switch Auto switch Ht Ht A A 32 B B L 9-6-20 21 Series MNB Cylinder with Lock Double Acting, Single Rod Proper Auto Switch Mounting Position D-F5W D-J59W D-F5 D-J5 D-F5BAL D-F59F D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W, D-Y7WV D-Y7BAL D-A3 D-A44 D-G39 D-K39 D-A5 D-A6 D-A59W D-F5NTL D-P5DWL Bore size (mm) A B A B A B A B A B A B A B 32 1 3.5 1.5 4 0 0.5 9.5 12 4.5 7 2 4.5 0 0.5 CL 40 1 3.5 1.5
MLGC 100 5.5 7 6 7.5 2.5 4 14 15.5 9 10.5 6.5 8 2.5 4 CNG Auto Switch Mounting Height D-Z7/Z-80 D-Y59 D-Y7P D-Y7W D-F5, D-J5 D-F59F D-F5W, D-J59W D-F5BAL, D-F5NTL D-A3 D-G39 D-K39 MNB D-A5 D-A6 D-A59W D-Y69 D-Y7PV D-Y7WV Bore size D-A44 D-Y7BAL D-P5DWL (mm) CNA Ht Hs Ht Hs Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht 31 38 23 30 23 26.5 23 25.5 27.5 77 27.5 67 32.5 25 35 24.5 32 CNS 33 42 26 34 26
Speed (mm/s) 250 3.5 2.3 1.5 1.2 1.1 500 2.4 1.8 1.4 1.2 1.1 Values will vary slightly depending on the operating conditions. A B C D Non-standard Motors: The following motors will be mounted when a motor mounted type is specified.
switch model D-A44 D-A44C D-F5 D-J59 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-A5/A6 D-F5W D-J59W D-F5BAL D-A3 D-G39 D-K39 D-A3C D-G39C D-K39C D-A5 D-A6 D-A59W D-A3/A3C D-A44/A44C D-G39/ G39C D-K39/K39C D-B5/B6 Bore size (mm) Bore size (mm) A B A B A B A B A B A B A B Hs Hs Hs Ht Hs Hs Ht Hs Hw Hs Hw 31 40 40 40 9.5 81 2 10.5 0 72.5 31 4 2 8.5 69 0 0.5 11.5 1.5 38 73 69 38.5 0 0 80.5 3.5 35 43.5
switch model D-A44 D-A44C D-F5 D-J59 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-A5/A6 D-F5W D-J59W D-F5BAL D-A3 D-G39 D-K39 D-A3C D-G39C D-K39C D-A5 D-A6 D-A59W D-A3/A3C D-A44/A44C D-G39/ G39C D-K39/K39C D-B5/B6 Bore size (mm) Bore size (mm) A B A B A B A B A B A B A B Hs Hs Hs Ht Hs Hs Ht Hs Hw Hs Hw 31 40 40 40 81 9.5 2 10.5 0 72.5 31 4 8.5 2 69 0 0.5 11.5 1.5 38 73 69 38.5 0 0 80.5 3.5 35 43.5
Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) 15 20 25 30 1000 1000 930 740 600 500 Model Note LG1H202PC-500-F LG1H202PC-600-F LG1H202PC-700-F LG1H202PC-800-F LG1H202PC-900-F LG1H202PC-1000-F 700 700 600 600 500 500 500 500 500 500 500 500 500 500 500 500 500 500 Power supply: 100/110(V)AC 10% Compatible controller: LC1-12HC1Power supply: 200/220(V)AC 10% Compatible