SMC Corporation of America
Elite Part Number Search
Search Results "CLA2B50-450-E"

CM01-8DP4S DDK Ltd. 10 Series PF2A Dimensions PF2A703H, 706H, 712H D E Internal circuits and wiring examples to are terminal numbers.

(Mounting thread) Note) If the fitting attached to the port interferes with the auto switch, please use the extension fitting assembly supplied with the air gripper. 4 x AA thread depth AB (Mounting thread) Prepared hole diameter AC through (Mounting hole) Note) AD depth AE AF depth AG S H When open AS When closed AR When closed AT M T D P B R N G Q F E C A 2 x AH thread depth AJ (Mounting

MB MC KA MA C N K N S + Stroke H B ZZ + Stroke Stroke range Bore size (mm) I J K M B D C E KA GA GB H 40 50 63 78 92 110 M6 x 1.0 M8 x 1.25 M8 x 1.25 25 25 25 10 14 14 45 55 68 21 26 32 36 46 53 34.5 40 46.5 40 45 50 46 55 66 59 71 82 23.5 28 34.5 to 1000 to 1000 to 1000 Stroke range Bore size (mm) MM XA XL Y ZZ MA MB MC N P S 40 50 63 M6 x 1.0 M8 x 1.25 M8 x 1.25 12 16 16 6 6 6 9.5 12.5

Bit 3 of SW2 SW1 Station Address Bit 3 of SW2 SW1 Station Address OFF 0 Disabled ON 0 50H OFF 1 41H ON 1 51H OFF 2 42H ON 2 52H OFF 3 43H ON 3 53H OFF 4 44H ON 4 54H OFF 5 45H ON 5 55H OFF 6 46H ON 6 56H OFF 7 47H ON 7 57H OFF 8 48H ON 8 58H OFF 9 49H ON 9 59H OFF A 4AH ON A 5AH OFF B 4BH ON B 5BH OFF C 4CH ON C 5CH OFF D 4DH ON D 5DH OFF E 4EH ON E 5EH OFF F 4FH ON F 5FH Turn the power

(3) 5A 10A R134a(HFC) AC100V/200V g 2805 2905 35010 Rc3/4 Rc1 10mm 1 2 kg 44 47 71 kW 7.5 11 15 1ANR 2065% 2 3 30mA 4() IDU Series 6-1 6 2 IDX-OM-W023 6 6-2 GWP (GWP) Regulation (EU) No 517/2014 IPCC AR4) R134a 1,430 1,430 R404A 3,922 3,920 R407C 1,774 1,770 R410A 2,088 2,090 (1) (2) IDU Series 6-2 GWP 6 3 IDX-OM-W023 6 6-3 A B E D Q Guige Guige G C Guige Guige [

Note 2) 1 (P) 3 (R) Note 3) 1.13-4 Series VQD1000 Construction JIS Symbol (A) 4 (B) 2 Part name Component Parts Note Material No. q w e r t y u i o !0 Solenoid coil assembly Sub-plate Body Spool valve Poppet Guide ring Return spring Manual override Gasket Round head screw VQD1000-S-M5(Base mounted only) Aluminum ZDC 1 (P) 3 (R) q u e !

e-t Tr' '],i(\tnralr.s Lightweight and Compact Built-in Auto Drain Port Sizes 1/4" 2" NEW PRODUCT GUIDE Ambient Dryer Series AMG Allows'Point of Use" installation wherever moisture needs to be removed from air supply. 99p/o of all Moisturc Can Be Removed Wide Range of Port Sizes Moisture can be removed at the air inlet or the Port sizes of 114 2 are available to meet air end of fie air line

Series: LEKFS, Size: 32, Motor Mounting Position: R (Right Side Parallel), Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: H (Size 25: 20mm, Size 32: 24mm, Size 40: 30mm), Stroke: 450

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 45 95 150 170 250 350 450 770 960 Surface: Munsell N-5.5, Inner surface: Non coated Safety valve (1 pc.) R 1/2 R 3/4 R 11/4 R 2 R 1 Accessory (2) Rc 1/2 Valve for drainage (1 pc.) Pressure gauge (1 pc.)

Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 450

Series: LEKFS, Size: 40, Motor Mounting Position: R (Right Side Parallel), Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 450, Motor Option: B (with Lock), Seal Band Stopper: N [Roller Type Seal Band Stopper [Grease Free]], Actuator Cable Type, Length: R5 (5), Controller: C9F (EtherNet/IPâ„¢ with STO Sub-Function

e-t Tr' '],i(\tnralr.s Lightweight and Compact Built-in Auto Drain Port Sizes 1/4" 2" NEW PRODUCT GUIDE Ambient Dryer Series AMG Allows'Point of Use" installation wherever moisture needs to be removed from air supply. 99p/o of all Moisturc Can Be Removed Wide Range of Port Sizes Moisture can be removed at the air inlet or the Port sizes of 114 2 are available to meet air end of fie air line

MC NFB Servomotor HC-PQ Power supply Single phase 200VAC (Type A) or Single phase 100VAC (Type A1) C P U L1 U V V W Servo amp SM L2 W MR-CA E or MR-CA1 The length of the cable between the controller and servo amp is 2m or less.

One-touch fitting 6 One-touch fitting 8 One-touch fitting Rc(PT)1/4 8 One-touch fitting 10 One-touch fitting Applicable series Type of actuation SY3000 2 position single (A) 4 (B) 2 1 SY5000 5 (EA) 3 (EB) 1 (P) 2 position double (A) 4 (B) 2 2 SY7000 5 (EA) 3 (EB) 1 (P) 3 position closed center (A) 4 (B) 2 3 Manual override 5 (EA) 3 (EB) 1 (P) 3 position exhaust center Nil: Non-locking push type E:

Station Address S1 S2 00H to 02H: Disabled 0 0 to 2 (Do not use these addresses.) 03H (Factory setting) 0 3 04H 0 4 EFH E F F0H to FFH: Disabled F 0 to F (Do not use these addresses.) (2) Settings of the DIP Switch S3 The following table shows the settings of the DIP switch (S3). Switch No.

Series: LEKFS, Size: 32, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 450

Dust-tight, Jet-proof Enclosure: Enclosure: Optional IP65 rating Optional IP65 rating Cylinder operation speed Cylinder bore size mm Valve width mm Cv Rubber seal (Metal seal) Cylinder speed mm/s Individual wiring style 40 50 63 80 100 125 140 150 kit (Connector) C 300 24.5 2.2 (2.0) 450 600 750 Pressure: 0.5MPa, Load rate: 50% Note) Cylinder speed varies according to piping construction

Series: LEKFS, Size: 32, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: H (Size 25: 20mm, Size 32: 24mm, Size 40: 30mm), Stroke: 450

Magnet: None, Mounting: B (Basic Style), Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 300mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: E [Spring Lock (Lock Exhaust)]