SMC Corporation of America
Elite Part Number Search
Search Results "CLA2D80TN-250-P"

Refer to pages starting with 181 for mounting. 30 95 B 100 95 8(4)-6.2 (160) () () 110 95 20 95 A (140) () () A B Stroke Model LG1H202PA-100-F LG1H202PA-200-F LG1H202PA-300-F LG1H202PA-400-F 100 200 300 400 50 150 250 70 170 270 Dimenstions inside ( ) are for a 100 mm stroke. Positioning Time Guide Positioning time Positioning time (sec.)

Stations L1 L2 L3 L4 2 135.5 125 105 15 3 4 5 6 7 8 9 10 160.5 150 137 11.5 185.5 175 153 16 210.5 200 185 12.5 235.5 225 201 17 260.5 250 233 13.5 148 137.5 121 13.5 198 187.5 169 14.5 248 237.5 217 15.5 Stations SS5Y5-45GDBC4 C6 C8 Stations L1 L2 L3 L4 2 148 137.5 123 12.5 3 4 5 6 7 8 9 10 185.5 175 155 15 210.5 200 187 11.5 235.5 225 203 16 260.5 250 235 12.5 285.5 275 251 17 198 187.5

When a large number of valves will be operated simultaneously, use type B (supply/exhaust on both sides), applying pressure to the P ports on both sides and releasing exhaust from the R ports on both sides.

Deflection + L F F (Dimension when extended) + M Built-in coil scraper and Lube-retainer MAllowable lateral load graph MSelectable proximity switches CKZP57L TURCK P&F 400 Allowable lateral load [N] 350 300 250 200 MAdjustable connector angle 150 100 CKZP57L: 45, 90 CKZP71: 0, 45, 90 50 0 0 50 100 150 200 250 Offset distance L [mm] CKZP71 0 50 100 150 200 250 300 350 400 450 500

RZQ R V Basic style (B): CG5BAS : With air cushion MI W S WA WB GA GB 2-P W 10 H1 Width across flats B1 CEP1 M BM CE1 Max.WH (E1) D CE2 B2 BZ MM AL A Plug bolt (4 pcs. included) ML2B K KA 8-J (F1) C 0.1 H S + Stroke ZZ + Stroke C J G5-S NA CV Stroke range A Bore size (mm) AL B1 B2 BM BZ C D E1 F1 GA GB H H1 I J K KA M MM NA P S MVGQ 20 Up to 350 18 15.5 13 7 M4 x 0.7 9 16.5 8 15 3 18 12

RZQ R V Basic style (B): CG5BAS : With air cushion MI W S WA WB GA GB 2-P W 10 H1 Width across flats B1 CEP1 M BM CE1 Max.WH (E1) D CE2 B2 BZ MM AL A Plug bolt (4 pcs. included) ML2B K KA 8-J (F1) C 0.1 H S + Stroke ZZ + Stroke C J G5-S NA CV Stroke range A Bore size (mm) AL B1 B2 BM BZ C D E1 F1 GA GB H H1 I J K KA M MM NA P S MVGQ 20 Up to 350 18 15.5 13 7 M4 x 0.7 9 16.5 8 15 3 18 12

Figure 2 Meter-out Meter-out C port Meter-in P A port Meter-in C port A port P B port D port Meter-in D port B port Meter-in P Meter-out Meter-out The table return position under the power-off state changes depending on the solenoid valve type. Please refer to page 299 for details. 3) Figure 3 shows the rotation range and Table 1 shows the active speed controller.

P-80 (D) This catalog is printed on recycled paper with concern for the global environment.

Standard Strokes Bore size [mm] Standard stroke [mm] Max. manufacturable stroke 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 45 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 56 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 63 25, 50, 75, 100, 125, 150

S 1 p c . n n p c s . L Long leads uountng B Front Nose Mount C -Rear Pivot E -Double End K -Non-Rotating Rod R -Block Mount W-Double Rod Auto.Switch 853. D-853 Gsg D-G59 B54. D-854 K59 D-K59 864 .

Order Made 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80 Symbol Specifications/Descriptions 1400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 XA 100 Change of rod end shape 1500 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450,

P (Port size) Operation P (Port size) Model CYV15 CYV32 Caution 5/16-24 UNF 7/16-20 UNF 1. The maximum operating pressure for the vacuum rodless cylinder is 0.3 MPa.

Note 1) Consult P/A if other specifications for surface treatment are required.

Note) If the set pressure is 250 kPa and the output pressure on the pressure sensor is 245 kPa, the deviation is 250 245 = 5 kPa. In order to correct the deviation, the controller increases the output signal until the pressure on the pressure sensor converges at 250 kPa. Step 1 Step 2 Step 3 Step 4 . . . . . . . . . . . . .

P.1785 (/) (/) 19 18-2. 12 16 20 25 32 40 50 63 80 100 1 2 1 2 1 15 2 15 1 15 2 15 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 2 10 15 5 10 5 10 10 5 10 D-A9 D-A9V D-M9V D-M9 10 10 10 10 D-M9W D-M9WV D-M9AVL 15 10 D-M9AL 15 10 5 D-Z7 D-Z80 D-Y59 D-Y7P D-Y69 D-Y7PV D-Y7W D-Y7WV 15 10 10 15 10 5 5 5 10 15 15 10 15 D-Y7BAL 10 20 75 18-3.

S 1 p c . n n p c s . L Long leads uountng B Front Nose Mount C -Rear Pivot E -Double End K -Non-Rotating Rod R -Block Mount W-Double Rod Auto.Switch 853. D-853 Gsg D-G59 B54. D-854 K59 D-K59 864 .

E F 24.5 G 60.5 H 5 I 70 J 60 K 5.5 L 72 M 37 N 2 O 30 P Rc1/4 Q R 59 Sa Sb T 500 U 250 V 310 Model ZH30--X185 ZH40--X185 28.5 146.5 M4 x 0.7 10 203 90 64 25 27.2 33.5 196.8 74.5 6 90 78 6.5 92 47 2.3 42 Rc3/8 76 500 250 310 Note 1) This thread portion is intended to adjust the product characteristics.

Check valve Pressure switch (for vacuum) Suction filter Variable throttle # P Variable throttle Suction filter 3 port valve is used to generate and stop the vacuum (vacuum release is performed simultaneously). Variable throttle is installed for break flow adjustment.