) 24VDC (10%) 24VDC (10%) 100 to 240VAC (10%) 100 to 240VAC (10%) 100 to 240VAC (10%) 24VDC (10%) 100 to 240VAC (10%) Power consumption 20VA or less 10W or less 20VA or less 10W or less 20VA or less 10W or less 10W or less 20VA or less Between case and AC line: 1500VAC for 1 min.
Bore size (mm) 10 15 25 10 15 25 Auto switch Nil Without auto switch Refer to the table below for auto switch model numbers.
Tighten the retaining screws to an appropriate tightening torque within the range given below. 6: 2.1 to 2.5 Nm, 10: 5.9 to 6.4 Nm, 16: 10.8 to 11.8 Nm 3.
3.14-10 Technical Information Channel selection function 13 Channel Selection Function is explained with an example when adsorbing work.
Please See Below for How to Order Piston Rod Assembly 7 Rod Bushing Bronze casting Available only as an Assembly Please See Rod/Head Cover NC1A400-10-124 NC1A200-10-124 NC1A250-10-124 NC1A325-10-124 8 Cushion Valve Carbon steel NC1A150-10-124 9 Tie Rod Carbon steel Please See Below for How to Order Tie Rod NCA325-13-Q6311 5008-131 NCA325-31-Q6311 NCA200-13-Q6309 5008-93 NCA250-13-Q6309 5008
to an axial rotation angle.
70 0.01 2 40 6000 100 40 0.1 3 90 1000 20 1 4 10 +3 5 5 10 +7 6 0 < Cp 5 +10 7 5 < Cp 10 Cw 0.5 8 0.5 < Cw 5 9 5 < Cw 10 x Cp > 10 Cw > 10 > 5 [How to Perform a Test to Check the Performance] ISO 12500, which sets out the test method to be used in order to check the filter performance for each of the three kinds of contaminants, is indicated below.
. 3 8 10 stations 10 Base type 01T, 10: 2 to 10 stations Base type 01C, 01F: 2 to 8 stations Symbol Porting specifications (A, B) Passage Symbol R1, R2 P 1 Side 2 Bottom Common Common Caution Option When using an exhaust cleaner, mount it downwards.
Class M1 to M7 U descriptor: Particles diameter smaller than 0.1 m (SI unit) (British unit) Corresponding class indication ISO Class 1 ISO Class 2 ISO Class 3 ISO Class 4 ISO Class 5 ISO Class 6 ISO Class 7 ISO Class 8 ISO Class 9 Cleanliness classes M1.5 M2.5 M3.5 M4.5 M5.5 M6.5 1 10 100 1000 10 10 The number of particles larger than 0.1 m in an air volume of 1m3 is expressed in 10 N.
H Caution 3.3 L 40 10 H Do not operate with the stroke adjusting unit fixed in an intermediate position.
2 (Different surfaces) 10 n 10 + 30 (n 2) D-A9l 2 (Same surface) 50 1, 2 (Different surfaces) 10 n 10 + 40 (n 2) D-A9lV 2 (Same surface) 40 1, 2 (Different surfaces) 10 n 10 + 30 (n 2) * n = 3, 4, 5 * The D-M9lV/M9lWV/M9lAV/A9lV are mountable on 32 to 63.
HRS012/018--10-T/MT HRS012/018/024/030--20-T HRS012/018/024/030--20-MTNote 1) Applicable model Rated flow50/60Hz Note 2) 3) 7(0.36MPa)/10(0.42MPa) 10(0.44MPa)/14(0.40MPa) 10(0.32MPa/)/14(0.32MPa) Pump 18/22 Maximum flow rate (50/60 Hz) L/min Maximum pump head (50/60 Hz) m 55 70 60 Output W 320 550 Circuit protector 15A (10 A for standard) A 15 Recommended earth leakage breaker capacity 15
A A1 E1 L1 MM RR1 U1 ND NX NZ L 34 41 42 56 71 79 8.5 16 25 30 30 40 50 55 M8 x 1.25 10.3 11.5 34 41 42 56 71 79 8.5 10.5 14 18 21 21 16 20 22 28 38 44 25 30 30 40 50 55 M8 x 1.25 10.3 12.8 12 16 21 24 11.5 14 14 20 27 31 8 10 10 14 18 22 8 10 18 22 28 32 8 10 10 14 18 22 8 10 18 22 28 32 IY-G02 IY-G03 IY-G04 IY-G05 IY-G08 IY-G10 20 25 32, 40 50, 63 80 100 I-G02 I-G03 I-G04 I-G05 I-G08 I-G10
I = I + IA kgm (m to m : Mass of I to I kg) D Calculation example When d1 = 0.1m, d = 0.05m, D = 0.04m, a = 0.04m, b = 0.02m m = 1kg, m = 0.4kg, m = 0.5kg, m = 0.2kg, Gear tooth ratio = 2 Cylinder: I I = 0.2 x = 0.03 x 10 -3kg m I = 1 x = 1.25 x 10 -3 kgm 0.1 8 0.04+0.02 12 b IB = (0.13 + 0.1 + 0.03) x 10 -3= 0.26 x 10 -3 kgm 0.05 8 I = 0.4 x = 0.13 x 10 -3 kgm a IA = 2 x 0.26 x 10 -3 = 1.04
Because the retaining screws extend into the cylinder, this could lead to an air leak. 1 15 D-A7/A8 D-A7H/A80H D-A73C/A80C 10 2 5 1 D-F7 D-J79 D-F7V D-J79C D-A79W D-F7W D-J79W D-F7BAL D-F7WV D-F79F Rail mounting 2 5 1 5 2 15 ( ) 10 1 10 16 2 15 D-F7LF 1 15 1.3-3 Series CJ2 Mounting Accessories/Refer to p.1.3-12 for details.
Select an air-hydro cylinder in combination with an air-hydro unit. Since good operation of an air-hydro cylinder depends on combination with an air-hydro unit, be sure to select an appropriate air-hydro unit. 2. Set the air-hydro cylinder's load at 50% or less of its theoretical output.
5 $0 @8 #7 #6 $1 F G Area G (10) Enlarged view F 10, 15 w u i o !1 #2 q !3 r y e @6 @5 @3 $1 #0 @7 #1 10 Component Parts Note No. Description Material No.
5st 5 st 5 st 10 st 10 st 10 st 10 st 10 st M4 x 0.7 6 6 9 10 12 5 50.5 22 44.5 4 7 14 5 10 8.5 19 60.5 27 54.5 13.5 24 M4 x 0.7 14 5 53 23.5 47 4 10 15 6.5 12 8.5 20.5 63 28.5 57 13.5 25.5 M6 x 1.0 20 8 61 24.5 52 5 12 18 8 16 9.5 23.5 71 29.5 62 14.5 28.5 M6 x 1.0 24 10 67.5 27.5 57.5 5 14 20 10 20 10 27.5 77.5 32.5 67.5 15 32.5 Double clevis bracket material: Carbon steel For details
Bore size/Stroke (mm) Bore size 6 10 15 20 25 32 Standard strokes 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 Applicable Auto Switches/Refer to page 15 for detailed auto switch specifications.