10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 10 102 1.
600 V(mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 Vertical Transfer 12 50 B B B 20 A 10 A A 40 H W(kg) W(kg) H 8 W(kg) 15 30 6 10 20 4 5 2 10 0 0 0 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 V (mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 50 12 B B 20 B A 10 A 40 H H A W(kg) W(kg) W(kg) 15 8 30 6 10 20 4 5 10 2 0 0 0 0 100 200 300 400 500 600 0 100 200
DL DD DA DU DC DX DE DO DR DT DS DH DF B W1 Z A B A + B + 90 CA1-B04 CA1-B05 CA1-B06 CA1-B08 CA1-B10 +0.058 0 11 57 35 65 15 85 10 9 17 8 40 52 60 10 234 10 +0.070 0 11 12 57 35 65 18 85 10 9 17 8 40 52 70 10 261 +0.070 0 13.5 12 60 162 67 40 80 25 105 12.5 11 22 10 50 66 85 10 280 16 +0.084 0 16.5 93 60 100 31.5 130 15 13.5 24 12 65 90 102 12 337 20 +0.084 0 16.5 93 60 100 35.5 130 15 13.5
DL DD DA DU DC DX DE DO DR DT DS DH DF B W1 Z A B A + B + 90 CA1-B04 CA1-B05 CA1-B06 CA1-B08 CA1-B10 +0.058 0 11 57 35 65 15 85 10 9 17 8 40 52 60 10 234 10 +0.070 0 11 57 35 65 18 85 10 9 17 8 40 52 70 10 261 12 +0.070 0 13.5 12 60 162 67 40 80 25 105 12.5 11 22 10 50 66 85 10 280 16 +0.084 0 16.5 20 93 60 100 31.5 130 15 13.5 24 12 65 90 102 12 337 +0.084 0 16.5 93 60 100 35.5 130 15 13.5
(For details, refer to page 4-4-25.) 4-4-20 21 3 Port Pilot Operated Solenoid Valve Rubber Seal Series SYJ500 Construction q e r t w y q e r t w y N.C. N.O.
EX260 Integrated-type (For Output) Serial Transmission System Series 10-SV RoHS How to Order Manifold 10-SS5V 10S1 D N 05 1 U W NA Enclosure IP67 Refer to Note 1) of the w SI unit specifications. w q e r y t u i q Series t P, E port location r Valve stations 1 2 3 U D B For 32-output SI unit 10-SV1000 10-SV2000 10-SV3000 U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2
1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 24 VDC 1 W DC (42 mA), 0.5 W DC (21 mA) 3 position exhaust center 12 VDC 1 W DC (83 mA), 0.5 W DC (42 mA) 2 position double (Metal) (A) 4 (B) 2 (A) 4 (B) 2 100 VAC Inrush 1.2 VA (12 mA), Holding 1.2 VA (12 mA) Power consumption (Current) 110 VAC Inrush 1.3 VA (11.7 mA), Holding 1.3 VA (11.7 mA) 1 (P) 5 (R1) 3 (R2) 200 VAC Inrush 2.4 VA (12 mA), Holding
-2)/2 n = 2, 4, 6, 8 160 10 10 + 55(n-2)/2 n = 2, 4, 6, 8 A5 A6 2 A59W n 15 15 15 10 10 + 55(n-2)/2 n = 2, 4, 6, 8 15 15 + 55(n-2)/2 n = 2, 4, 6, 8 10 100 35 1 1, 2 F5(W)/J5/J59W n F5BAL/F59F 15 15 1, 2 F5NTL n 10 100 35 1 2 (Same side) 2 (Different sides) A3 K3 G3 n (Same side) n (Different sides) 10 55 35 10 55 35 1 2 (Same side) 2 (Different sides) A44 n (Same side) n (Different
2 (On different faces or same face) 15 130 125 120 95 75 70 25 D-F5NTL 1 10 D-F5 W D-J59W D-F5BAL D-F5 F D-F5LF 2 (On different faces or same face) 15 130 125 120 90 75 70 25 10 1 Auto Switch Mounting Position and Mounting Height Reed switch Solid state switch Auto Switch Mounting Position Auto Switch Mounting Height D-F5, D-J5 D-F5 W, D-J59W D-F5BAL, D-F5NTL D-A5 D-A6 D-A59W D-F5 W D-J59W
ZS-22-A H O W T O O R D E R P O S I T I V E P R E S S U R E S W I T C H S E R I E S ISE4 H O W T O O R D E R V A C U U M P R E S S U R E S W I T C H S E R I E S ZSE4 PANEL MOUNTING KIT ZS-22-A ZSE4B ISE4 B O P E R AT I N G P R E S S U R E O P T I O N S -0.1 ~ 1MPa L -10 ~ 100KPa Non-Backlit (Standard) B Backlit LCD O P T I O N S P I P I N G S P E C I F I C AT I O N S Non-Backlit (Standard
Applicable air dryer Capacity Type Inlet voltage Outlet voltage A B C D E F Weight IDF-TR500-3 IDF1E-10 to 8E-10 IDU3E-10, 4E-10, 8E-10 500 VA 380, 400, 415 VAC (50 Hz) 380 to 420 VAC (60 Hz) 100 VAC (50 Hz) 110 VAC (60 Hz) 15 kg IDF-TR1000-3 IDF11E-10, 15E1-10 IDU6E-10, 11E-10, 15E1-10 1 kVA Singlephase Singleturn 230 207 190 210 160 9 IDF-TR500-4 IDF1E-10 to 8E-10 IDU3E-10, 4E-10, 8E-10
H w H w H e e H H r 2.2-2 Series KJ Male connector: KJH Thread (T) UNF NPT 10-32UNF <10-32UNF> <10-32UNF> Tube O.D. (inch) H (Hex.) Min. hole dia.
(Example) For M5: L1 = 10 Applicable shaft types: S, W, Y Minimum machining diameter for d1 is 0.1. Applicable shaft types: S, W, Y The maximum dimension L2 is, as a rule, twice the thread size.
[C] HRS100-W-20/40(60 Hz) HRS100-W-20/40(50 Hz) 14 14 Facility water temperature 32C 12 12 Cooling capacity [kW] Cooling capacity [kW] Facility water temperature 32C 10 10 8 8 6 6 4 4 Facility water temperature 40C Facility water temperature 40C 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRS150-A-20/40(50 Hz) HRS150-
W or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less Power consumption Between case and AC line: 1500 VAC for 1 min.
W or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less Power consumption Between case and AC line: 1500 VAC for 1 min.
psig (2.1 MPa) Vacuum to 3500 psig (24.1 MPa) 1) Source pressure 5000 psig (34.5 MPa) 10 psig (69 MPa) 40 to 160C (40 to 71C) (No freezing) 2) 0.09 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 3) 4 x 10-9 Pam3/sec 4) Ra 10 in. (0.25 m) Option: 25 in. (0.62 m) Face seal, Tube weld 0.38 pisg (0.0026 MPa) rise in delivery pressure per 100 psig (0.7 MPa) source pressure drop Bottom mount (Option: panel
Grease pack part number: GR-S-010 (10 g), GR-S-020 (20 g) 11 Cylinder with Lock Double Acting, Single Rod MWB Series Dimensions Basic: MWBB MWB MWBW MWB-UT Model Selection GD GD (Rc, NPT, G) BP Unlocked when pressurized GB GD GC GB GB GC GA (Rc, NPT, G) P Rod side cylinder port (Rc, NPT, G) P Head side cylinder port GE W W GE E GE W (Rc, NPT, G) BP GF Double Acting, Single Rod Double Acting