Never use in an atmosphere of explosive gases. The construction of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated.

Data View A-A Mounting dimensions Bore size (mm) Stroke range (mm) N M L K J I B AP AO AN AM AL AK AJ AI AH AG AB AA A 20 25 32 40 50 75, 100, 125, 150, 200 25 38 80 60 44 25 106 22 M6 110 55 9 6.6 90 75 120 105 13 11 84 32 46 95 70 52 30 120 27 M8 125 65 9 9 100 84 136 120 13 15 89 75, 100 125, 150 200, 250 300 32 50 105 80 60 35 135 32 M8 140 75 9 9 108 92 150 134 13 15 94 38 60 125 95

To operate a relay as a load, use the relay shown in the table below or the equivalent, in order to extend the life of the switch. qWhen handling the product, do not drop an object on it, gouge it, or apply an excessive impact on it. wDo not operate it in an area in which a large amount of magnetism is present.

Cannot be used as an emergency shutoff valve, etc. The valves presented in this catalog are not designed for safety applications such as an emergency shutoff valve. If the valves are used in this type of system, other reliable safety assurance measures should also be adopted. 2.

VCKK1209-02F VCKK1008-02F VCKK1075-02F VCKK0806-02F VCKK0604-02F Symbol F G H J K Part no.

DNote) When the digital filter setting (ON/OFF) is changed, an error count will occur. Reset the count value.

I Compact Guide Cylinder with One-way Lock Series MLGP 40, 50, 63 Prevents dropping when air supply pressure falls or residual pressure is exhausted Can be locked at any position The locking position can be changed to accommodate an external stopper position or the thickness of clamped work pieces, etc.

To replace seals or grease the cylinder during maintenance, use an appropriate pair of pliers (tool for installing a type C snap ring for hole). After re-installing the cylinder, make sure that the snap ring is placed securely in the groove before supplying air. 2.

To replace seals or grease the cylinder during maintenance, use an appropriate pair of pliers (tool for installing a type C snap ring for hole). After re-installing the cylinder, make sure that the snap ring is placed securely in the groove before supplying air. 2.

Standard 1 2 3 4 5 6 7 Stainless steel Clip Stainless steel, Cu Tube assembly Class H Coil assembly Stainless steel, PTFE (FKM) Armature assembly PTFE (FKM) Seal Stainless steel Return spring Brass Body Dimensions (mm)/Bracket 1in = 25.4mm A J 4-G C 1.5 B D E L 4-H Valve mounting hole F Bracket mounting dimensions (mm) B C D E F G H J L A Bracket part no.

(Assuming approximately 30% dispersion) There may be the case it will vary substantially depending on an ambient environment.

Also, BBA2 is included when an auto switch alone is shipped.

In addition, by connecting an input block a maximum of 32 sensor signal inputs are possible. Input block This is an expansion block which connects to an SI unit to perform sensor input from auto switches, etc. Two or four sensor inputs can be accommodated by one input block, and the common can be matched to the sensor by an NPN/PNP switch.

MSQ Angle adjustment Range Figure 5 MSZ MSZ CRQ2X MSQX ad a ge ju Cl lt MRQ an st bo oc t r m nd en g k en tm wi in e us 10 10 se t r st on dj a ju an r on ti ot ad iti ta os ge at p ro er y nt io e b C e b n y is e ge n ad w d k an c ju lo t r C st in en g m bo st lt ju b ad M 0 ax 19 im e u ng m ra ro n ta tio Center position adjustment Table 2 R: Clockwise adjustment L: Counterclockwise

Method (Operation example with an energy saving driver circuit) 2.

VXA22 , , 18 21 9 10.5 40 45 21 27 55 62 64 71 11 13 36 46 46 56 11.5 Dimensions (Orifice Size: 8 mm, 10 mm) VXA225/VXA226 Thread fixed: (VXA2262 0-04 only) 2-M5 x 0.8 depth 8 Dimension of view from A Pilot port Port size P Rc , With bracket E Port size View from A Model A B C D VXA22 52 60 02 03 VXA226 -04 2 0 1 4 3 8 22 28 11 14.5 67 73 77 83 27 30 1 2 Fixing with thread is also possible

Select an appropriate manifold assembly part number from the table below.

(An assembly is shipped under the condition shown in the figure.)

When actually mounting an auto switch, adjust the position after confirming the operating state of the auto switch.

Use a contact protection box in cases such as with an induction load, when the lead wire is longer than 5m or with 100VAC. 1 Operating load is an induction load. 2 Wiring to the load is 5m or longer. Contact protection box internal circuits 3 Load voltage is 100VAC. CD-P11 Use a contact protection box in any of the above listed situations.