The position of spanner should be a root as close as possible to R thread. Hex. across flats may be deformed, if using an improper wrench for hex. across flats.
to 500 20 to 600 20 to 600 20 to 750 20 to 750 30 to 1000 30 to 1000 30 to 1200 27 32 32 37 37 47 47 53 60 70 86 102 116 145 161 182 22 27 27 32 41 59 67 73 77 85 112.5 121 133 69 78 84 92 100 141.5 150 167 44 52 64 78 92 115 128 144 10 12 16 20 25 25 28 32 17 17 20 16 20 20 25 30 36 36 40 40 50 55 65 80 90 90 90 6.5 6.0 6.0 8.0 8.0 43 43 43 14 14 14 15 17 17 21 21 16 16 18.5 15 17 17 21
The I/O map is shown with the following unit configuration as an example.
For stopping accuracy, refer to Series CLJ (P. 9-2-12), Series CLM2 (P. 9-2-20), Series CLG1 (P . 9-2-30), and Series CL1 (P . 9-3-2) respectively. 7. In order to further improve stopping accuracy, the time from the stop signal to the operation of the lock should be shortened as much as possible.
as standard) Outdoor installation IPX4 (400 V as standard) HRS100/150 Standard type 1.0 5 to 35 V V (400 V as standard, 200 V as an option) HRSH090 Inverter type 0.1 5 to 40 V Indoor use (Only 200 V as an option) (400 V as standard, 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (Only 200 V as an option) 73 Circulating Fluid Temperature Controller
When designing an application, be sure to allow sufficient clearance for maintenance and inspections. V (mm/s) = Auto switch operating range (mm) Load operating time (ms) x 1000 In case of high piston speed, the operating time of the load can be extended by using an auto switch (D-F7NT) with built-in OFF delay timer (approx. 200ms). 4. Keep wiring as short as possible.
Do not use in an environment with temperature cycles. Consult SMC if switches are used where there are temperature cycles other than normal air temperature changes, as they may be adversely affected internally. 6. Do not use in an environment where there is excessive impact shock.
The standard bowl for the air filter, filter regulator, and lubricator, as well as the sight dome for the lubricator are made of polycarbonate. Do not use in an environment where they are exposed to or come in contact with synthetic oil, organic solvents, chemicals, cutting oil, alkali, and thread lock solutions such as Loctite products. 2.
-X5 is not added to an actuator model with a controller/driver part number suffix. Example) LEY25DB-100 for the LEY25DB-100BMU-R16N1D-X5 Stroke Model 30 50 100 150 200 250 300 350 400 450 500 Manufacturable stroke range [mm] LEY25 15 to 400 LEY32 20 to 500 Please consult with SMC for non-standard strokes as they are produced as special orders.
Note 3) Operate an interface regulator only by applying pressure from the P port of the base, except when using it as a reverse pressure valve. To combine a pressure center valve and the A and B port pressure reduction of an interface regulator, use the ARBF3000, 4000, or 5000 model.
Attachment should be designed as light and short as possible. 1. Long and heavy attachment increases the inertia force to open or close the fingers. It may cause unsteady movement of fingers and have an adverse effect on life. 2. Even if holding point remains within the limited range, make the attachment as light and short as possible. 1.
Keep wiring as short as possible to prevent interference from electromagnetic noise and surge voltage. Do not use a cable longer than 20 m. Wire the DC(-) line(blue) as close as possible to the power supply. Environment Do not use the product in area that is exposed to corrosive gases, chemicals, sea water, water or steam. Otherwise failure or malfunction can result.
item. *3 The USB cable (LEC-MR-J3USB) must be purchased as an additional item.
When the conduit type is used as equivalent to an
Operating Range (mm) Bore size Switch types 25 32 20 D-A9, D-A9V D-F9, D-F9V D-F9W, D-F9WV 11 12.5 14 6.5 7 7 Values in this table include hysteresis and are to be used as a guide only. They do not guarantee an actual fixed range (expect approximately 30% dispersion).
Standard Stroke Model Standard stroke (mm) 10, 20, 30, 40, 50 MXQ6 10, 20, 30, 40, 50, 75 MXQ8 10, 20, 30, 40, 50, 75, 100 MXQ12 10, 20, 30, 40, 50, 75, 100, 125 MXQ16 10, 20, 30, 40, 50, 75, 100, 125, 150 MXQ20 10, 20, 30, 40, 50, 75, 100, 125, 150 MXQ25 8-5-9 10 Series MXQ Theoretical Output IN OUT The dual rod ensures an output twice that of existing cylinders.
Specify the mounting position, as well as the EXH block base or EXH block plate position by means of the manifold specification sheet. The block plate is used in one or two places for one set. An EXH block base assembly is used in the blocking position when ordering an EXH spacer incorporated with a manifold no.
Specify the mounting position, as well as the EXH block base or EXH block plate position by means of the manifold specification sheet. The block plate is used in one or two places for one set. An EXH block base assembly is used in the blocking position when ordering an EXH spacer incorporated with a manifold no.
Keep the lead wire length as short as possible.