-X5 is not added to an actuator model with a controller/driver part number suffix. Example) LEY25DB-100 for the LEY25DB-100BMU-R16N1D-X5 Stroke Model 30 50 100 150 200 250 300 350 400 450 500 Manufacturable stroke range [mm] LEY25 15 to 400 LEY32 20 to 500 Please consult with SMC for non-standard strokes as they are produced as special orders.
Note 3) Operate an interface regulator only by applying pressure from the P port of the base, except when using it as a reverse pressure valve. To combine a pressure center valve and the A and B port pressure reduction of an interface regulator, use the ARBF3000, 4000, or 5000 model.
Attachment should be designed as light and short as possible. 1. Long and heavy attachment increases the inertia force to open or close the fingers. It may cause unsteady movement of fingers and have an adverse effect on life. 2. Even if holding point remains within the limited range, make the attachment as light and short as possible. 1.
Keep wiring as short as possible to prevent interference from electromagnetic noise and surge voltage. Do not use a cable longer than 20 m. Wire the DC(-) line(blue) as close as possible to the power supply. Environment Do not use the product in area that is exposed to corrosive gases, chemicals, sea water, water or steam. Otherwise failure or malfunction can result.
item. *3 The USB cable (LEC-MR-J3USB) must be purchased as an additional item.
When the conduit type is used as equivalent to an
Operating Range (mm) Bore size Switch types 25 32 20 D-A9, D-A9V D-F9, D-F9V D-F9W, D-F9WV 11 12.5 14 6.5 7 7 Values in this table include hysteresis and are to be used as a guide only. They do not guarantee an actual fixed range (expect approximately 30% dispersion).
Standard Stroke Model Standard stroke (mm) 10, 20, 30, 40, 50 MXQ6 10, 20, 30, 40, 50, 75 MXQ8 10, 20, 30, 40, 50, 75, 100 MXQ12 10, 20, 30, 40, 50, 75, 100, 125 MXQ16 10, 20, 30, 40, 50, 75, 100, 125, 150 MXQ20 10, 20, 30, 40, 50, 75, 100, 125, 150 MXQ25 8-5-9 10 Series MXQ Theoretical Output IN OUT The dual rod ensures an output twice that of existing cylinders.
Specify the mounting position, as well as the EXH block base or EXH block plate position by means of the manifold specification sheet. The block plate is used in one or two places for one set. An EXH block base assembly is used in the blocking position when ordering an EXH spacer incorporated with a manifold no.
Specify the mounting position, as well as the EXH block base or EXH block plate position by means of the manifold specification sheet. The block plate is used in one or two places for one set. An EXH block base assembly is used in the blocking position when ordering an EXH spacer incorporated with a manifold no.
Keep the lead wire length as short as possible.
Note 2) The time required for 90% valve movement when an actuation pressure of 0.5MPa (72psi) is applied. There is a difference of about 20% in this value at the upper and lower pressure limits.
The unit to connect input device such as an auto switch, pressure switch and flow switch, and the unit to connect output device such as a solenoid valve, relay and indicator light can be connected in any order.
Take appropriate measures to avoid freezing of drain, moisture etc. by use of an air dryer. Not suitable for use as an emergency shutoff valve The valve represented in this catalog is not intended for use as an emergency shutoff valve.
Real-time switch output, accumulated switch output, or accumulated pulse output can be selected as an output type.
4 46 63 61 102 20 0 41 80 84 143 25 9.5 68.5 100 89 153 30 5 69 Other dimensions are the same as for slide bearing.
Intermediate stopping of load with an air pressure circuit When stopping a load using an air pressure circuit, operate at or below the kinetic energy shown in the table below. Use caution, as operation when exceeding the allowable value can result in breaking of the magnetic coupling.
12 10 20 20 20 40 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 2 Horizontal 8 25 25 18 Standard motor 8 12 8 12 24 5 10 5 10 Vertical 32 10 12 10 20 10 12 10 20 40 High rigidity direct acting guide LJ1H 20 20 40 44 Horizontal 50 25 25 60 Non-standard motor 8 12 8 12 66 5 10 5 10 Vertical 74 10 10 82 Options Page 100 Made to Order 101 Clean room