How to Order Integrated Display Type PF2W7 20 T 03 27 Flow rate range Unit specification T Temperature range 0.5 to 4 l/min 2 to 16 l/min 5 to 40 l/min 04 20 40 0 to 90C Nil M With unit switching function Lead wire (Refer to page 35.)
maintenance Selectable between T-branch and straight type of communication connector EX510 Gateway system Serial transmission system M Max. 128 points (Input 64 points/Output 64 points) M All wires can be plugged into the connector units.
Non plug-in type N T F Symbol 24 24 stations NPTF G Option VV5ZS3-51FD-091-01-MP5 VZS3150-5FZ VZS3250-5FZ 1 5 2 Passage Porting specifications 4(A), 2(B) Side 5(R1), 3(R2) 1(P) Common Common Note) Maximum stations 51F 16 stations 51G 15 stations 51 24 stations Symbol Port size 1 1 8 02 Rc 1 4 01 Rc (Manifold base) (2 position single) VV5ZS3-50-071-01-M5 VZS3150-5G 1 5 Embedded type One-touch
M plug connector 2 position double: VZS3250-M(Z)-01 02 3 position closed center: VZS3350-M(Z)-01 02 3 position exhaust center: VZS3450-M(Z)-01 02 3 position pressure center: VZS3550-M(Z)-01 02 DIN terminal 2 position double: VZS3250-D(Z)-01 02 3 position closed center: VZS3350-D(Z)-01 02 3 position exhaust center: VZS3450-D(Z)-01 02 3 position pressure center: VZS3550-D(Z)-01 02 164 (3 position
Load (kg) Load (kg) 10 10 30 10 100 300 Speed (mm/s) Speed (mm/s) Speed (mm/s) 300 300 REA REB Stroke Stroke Speed REC CY Time Time Stroke P=0.5 MPa,M=10 kg P=0.3 MPa,M=10 kg M=10 kg M=30 kg V=300 mm/s V=100 mm/s CX MQ Model Recommended Speed Controllers Caution RHC RZQ Model Elbow type Straight type In-line type REC20 AS2201F-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 REC25 AS2201F
Load (kg) Load (kg) 10 10 30 10 100 300 Speed (mm/s) Speed (mm/s) Speed (mm/s) 300 300 REA REB Stroke Stroke Speed REC CY Time Time Stroke P=0.5 MPa,M=10 kg P=0.3 MPa,M=10 kg M=10 kg M=30 kg V=300 mm/s V=100 mm/s CX MQ Model Recommended Speed Controllers Caution RHC RZQ Model Elbow type Straight type In-line type REC20 AS2201F-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 REC25 AS2201F
Load (kg) Load (kg) 10 10 30 10 100 300 Speed (mm/s) Speed (mm/s) Speed (mm/s) 300 300 REA REB Stroke Stroke Speed REC CY Time Time Stroke P=0.5 MPa,M=10 kg P=0.3 MPa,M=10 kg M=10 kg M=30 kg V=300 mm/s V=100 mm/s CX MQ Model Recommended Speed Controllers Caution RHC RZQ Model Elbow type Straight type In-line type REC20 AS2201F-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 REC25 AS2201F
VC Model VDW VQ Thread type Nil T F N Orifice size Rc NPTF G NPT 1 2 3 4 1.5 mm 2.2 mm 3 mm 4 mm VX2 VX Refer to the table (1) given below for availability. VX3 Port size 01 02 03 1 8 1 4 3 8 VXA Valve/Body 4 Common/Single unit Refer to the table (1) given below for availability.
L2 L3 M D2 D2 L1 L1 L4 L4 H (Hexagon width across flats) H (Hexagon width across flats) D3 D3 L5 A1 A2 L5 A1 A2 D1 D1 T T Metric Size L4 L5 A1 A2 M Max.
M D2 D2 L1 L1 L4 L4 H H (Width across flats) (Width across flats) D3 D3 A1 L5 L5 A1 A2 D1 D1 A2 T T Metric L4 L5 A1 A2 M MAX.
Inlet pressure 0.5 MPa Total stroke time (t) (1) Piping length SV1000: 1 m, SV2000/3000: 2 m, SV4000: 3 m Stroke (L) Speed d% d% Stroke (mm) Speed at the end Cylinder direction Vertical upward Stroke Speed controller Meter-out, Directly connected to cylinder, Needle fully open (2) Load ratio {(Load weight x 9.8) Theoretical output} x 100% Speed at the end (u) Time (s) SOL: ON(OFF) 1-2-6
across flats) Effective area (mm 2) Nylon Urethane 2.6 6.8 16.2 25.6 35.4 Applicable Connection Weight (g) Mounting T (M) Mounting plate thickness 7 mm or less tubing thread Rc 4 6 8 10 12 Model L1 L2 M hole O.D.
Port 3/4 3/4, 1 D I M E N S I O N S AD S E R I E S A U I T O D R A I N S S Y M B O L S H O W T O O R D E R A U T O D R A I N S E R I E S AD AD402-02 (1/4) PT AD402-03 (3/8) PT AD402-04 (1/2) PT AD600-06 (3/4) PT AD600-10 (1) PT H O W T O O R D E R A U T O D R A I N S E R I E S NAD NAD402-N02 (1/4) NPT NAD402-N03 (3/8) NPT NAD402-N04 (1/2) NPT NAD600-N06 (3/4) NPT NAD600-N10 (1) NPT FOR FURTHER
Kit/Electrical entry/Cable length F T kit (D-sub connector) kit (Terminal block box kit) Cylinder port C8 C10 C12 02 03 B CM With One-touch fitting for 8 With One-touch fitting for 10 With One-touch fitting for 12 Rc 1/4 Rc 3/8 Bottom ported Rc 1/4 Connector entry direction D side U side Mixed U0 U1 U2 U3 D0 D1 D2 D3 Without cable Cable length 1.5 m Cable length 3 m Cable length 5 m Terminal
Electrical entry q Description 01 02 03 01 02 03 01 02 03 Mounting bolt and gasket are not included. Platinum silver Body C: Conduit VS4010-CSSub-plate Platinum silver Aluminum die-casted w T: Conduit terminal VS4010-TSSpool/Sleeve Stainless steel e U: Grommet, D: DIN terminal VS4010-SReplacement Parts Part no. No.
Description Material Note q w e r t y u i o !0 !1 !2 !3 !4 !
A, B port size Port size M5 x 0.8 1/8 1/4 3/8 Symbol M5 01 02 03 VFA1000 VFA3000 VFA5000 VFA1000 Double type only Thread type (Including pilot port) Nil F N T Rc G NPT NPTF M5 is available with Nil only.
Dynamic moment MG Va Calculation Example CX m Operating Conditions Cylinder: CYP32 Mounting: Horizontal wall mounting Maximum speed: U = 300 [mm/s] Load mass: m = 1 [kg] (excluding mass of arm section) L1 = 50 [mm] L2 = 50 [mm] D-X L2 L1 20Data Item Load factor n Note 1. Maximum load mass m 1 = m/mmax = 1/5 = 0.20 L2 Review m. L1 M2 = m g (L1 + B) 103 2.
Maximum load mass m 1 = m/mmax = 1/5 = 0.20 L2 Review m. L1 M2 = m g (L1 + B) 103 2. Static moment m x g = 1 9.8 (50 + 48) 103 Review M2. Since M1 & M3 are not generated, review is unnecessary. = 0.96 [Nm] 2 = M2/M2 max = 0.96/4 = 0.24 M Guide shaft mounting surface L1 B We = 5 x 103 m g U = 5 x 103 1 9.8 300 = 14.7 [N] Me3 = 1/3 We (L2 + A) 103 3.
Dynamic moment Va Calculation example m Operating conditions Cylinder: CYP32 Mounting: Horizontal wall mounting Maximum speed: U = 300 [mm/s] Load mass: m = 1 [kg] (excluding mass of arm section) L1 = 50 [mm] L2 = 50 [mm] L2 L1 Item Load factor n Note 1. Maximum load mass m 1 = m/mmax = 1/5 = 0.20 L2 Review m. L1 M2 = m g (L1 + B) 103 2.