OUT() DC(-) DC(+) PSE57--28 420 mA N.C. 500 (24 V ) 100 (12 V ) OUT() DC(-) -13No.PS-OMS0004CN-D (A/D ) () 20 2030 -14No.PS-OMS0004CN-D PSE570 PSE573 PSE574 01MPa -100100 kPa 0500 kPa 3.0MPa 600 kPa 1.5MPa oC) oC) (25 ) 2F.S.(050 3F.S.(050 oC) oC) 3F.S.(-1060 4F.S.(-1060 PSE57PSE57--28 DC1224 V1010% 10 mA 420 mA 15 V 1 k 500 (24 V ) 100 (12 V ) (25 oC) 1.0F.S. 0.5F.S. oC)
Mount the filter case securely, otherwise the V port may come off or be damaged. Filter case (2) The V port assembly and removal may not be easy if the product is mounted on the floor. If it is forcibly mounted or removed, the V port assembly may be damaged and/or it may cause vacuum leakage.
Budafoki ut 107-113 1117 Budapest TEL: 01-371-1343 FAX: 01-371-1344 SOUTH KOREA SMC Pneumatics Korea Co., Ltd. Woolim e-BIZ Center (Room 1008), 170-5, Guro-Dong, Guro-Gu, Seoul, 152-050, South Korea TEL: 02-3219-0700 FAX: 02-3219-0702 ROMANIA SMC Romania S.r.l. Str.
OFF: Solenoid valve power supply voltage is less than 19 V. PW(V) ON: Normal traffic OFF: Traffic disconnected (Timeover error) L RUN ON: Traffic error BLINKING: Station or baud rate switch is set while the power supply is ON. OFF: Normal traffic L ERR When the data link is normal, PW, PW (V) and L RUN are ON.
IS1000-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Differential 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V 24 V Voltage (AC, DC) 50 mA 40 mA 20 mA 50 mA Max. current 1.2 ms Operating time 30 G Shock resistance JIS Symbol AMR5100 AMR4000 AMR3000 14-7-1 2 Series AMR3000 to 6000 How to Order E3 03 R S AMR 4 0 00 Adapter Assembly (Part
IS1000-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Differential 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V 24 V Voltage (AC, DC) 50 mA 40 mA 20 mA 50 mA Max. current 1.2 ms Operating time 30 G Shock resistance JIS Symbol AMR5100 AMR4000 AMR3000 14-7-1 Series AMR3000 to 6000 How to Order E3 03 R S AMR 4 0 00 Adapter Assembly (Part
SUP. 3 1 2 3 1 2 3 1 2 E Padlock mounting position D C SUP J 2 2 x K A T IN OUT AA 3 L 2 x P1 (Port size) B V BB U Built-in silencer (Option) M (Width across flats) 3 N P2 (Port size) Q EXH Y Bracket (Option) R S X W Dimensions (mm) Standard specifications Model P1 P2 A B C D E F G H I J K L M 1/8, 1/4 1/4, 3/8 1/8 1/4 3/8 1/2 1/2 66.4 80.3 104.9 110.4 134.3 22.3 29.4 38.5 42 53 40 53 70
Compact Pressure Switch Specifications (For further information, refer to Best Pneumatics No. 8) IS10-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Hysteresis 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V Voltage (AC, DC) 24 V 50 mA 40 mA 20 mA Max. current 50 mA Symbol 2 1 AMR4000 AMR3000 L AMR5100 686 Regulator with Mist Separator
Metal ( shaded) part Metal ( shaded) part Tap for ground wiring Resin part ( shaded) 454 Ionizer IZN10 Series Power Supply Cable Connection Circuit NPN PNP Ionizer Ionizer IZS Brown +24 VDC Brown +24 VDC +24 V +24 V Power supply 24 VDC 10% 0 V +24 V Power supply 24 VDC 10% 0 V +24 V Blue 0 V Blue 0 V IZN IZN INPUT PLC OUTPUT OUTPUT PLC INPUT IZF Orange Discharge stop signal Orange Discharge
Make sure to ground. +24 V +24 V Brown + 24 VDC Brown + 24 VDC +24 V Power supply 24 VDC +24 V Power supply 24 VDC Blue 0 V Blue 0 V 0 V 0 V F.G. F.G. Make sure to ground. Make sure to ground.
(Example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analog output of 5V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V.) Output impedance P Peak hold mode Shows the maximum pressure reached at that moment.
Max. voltage (with no load): 30 Vrms (42.4 V peak) or less Max. current: 8 A or less (including shorts), and When controlled by a circuit protector (fuse) with the following ratings: No-load voltage (V peak) Max. current rating 0 to 20 [V] 5.0 100 Over 20 [V] and up to 30 [V] Peak voltage value (2) A circuit (class 2 circuit) with maximum 30 Vrms (42.4 V peak) or less, and a power supply
B5 White Unused 1) NPN type Ionizer (IZS41, IZS42) When an ionizer (IZS41) is used in DC mode, make sure to ground the F.G. cable (green) and 0 V cable (blue) Shield Green: F.G. +24V F.G. Brown (2pcs.): +24 VDC + DC/DC + +24 V Power supply 24 VDC Blue (2pcs.): 0 V 0 V 0 V 0 V F.G. PLC INPUT Internal circuit F.G.
VH*-OMX0068-C PRODUCT NAME Pressure Relief 3 Port Valve with Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40-(F,N)02~(F,N)04(-B,S)(-K,M,R,Z)-D VHS40-(F,N)06(-B,S)(-K,M,R,Z)-D VHS50-(F,N)06~(F,N)10(-B,S)(-K,M,R,Z)-D VHS20W-(F,N)01~(F,N)02(-B,S)(-K,M,R,Z)-D VHS30W-(F,N)02~(F,N)03(-B,S)(-K,M,R,Z)-D VHS40W-(F,
KPQY12-04 KPGY04-M5 KPGY04-01 KPGY04-02 KPGY06-M5 KPGY06-01 KPGY06-02 KPGY08-01 KPGY08-02 KPGY10-02 KPGY10-03 KPGY12-03 KPGY12-04 M5 1/8 1/4 M5 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 8 10 14 8 10 14 12 14 8 15.3 22 26 15.8 23.2 27.2 24.4 28.4 29.9 31.9 33.1 37.1 32.5 36.5 40.5 35 40 44 44.5 48.5 53.5 55 58 60.5 6 13 19 7 14 20 14 22 29 39 41 68 4 4 4 18 20.7 10.4 D1 10 M M L1 8 L2 A D1 6 K 10 10
These vortexes are stable under certain conditions, and their frequency is proportional to the flow velocity, resulting the following formula. f = k x v f: Frequency of vortex v: Flow velocity k: Proportional constant (determined by the vortex generator's dimensions and shape). Therefore, the flow rate can be measured by detecting this frequency.
Note VZ4000-22A For VZ42 AN110-01 Noise reduction: 21 dB (13 x 38l ) AN203-02 Noise reduction: 25 dB (16 x 36l ) Description R 1/8 R 1/4 (2) Silencer Note 1) For body ported type Note 2) For sub-base mounted type 4-15-10 11 3 Port Solenoid Valve Metal Seal, Body Ported/Base Mounted Series VZ400 How to Order Option 01 1 2 VZ4 G 1 Foot bracket F Silencer U Foot bracket + Silencer K Only body
CYRZ-V CYRZ-W CYRZ-X CYRZ-Y 12REA Warning 1. Do not disassemble the product because it may damage the air cushion mechanism.