SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-V-P-01-S"

MLGP Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL RLQ MLU ML1C Auto Switch Mounting Bracket Part No.

Table 1 Table 2 Output type ON YES Hysteresis mode For air OFF P-1 P-2 Display Instantaneous flow rate l/min Cumulative flow rate l Large flow rate "P" H H H (fixed hysteresis) = 3 digits CFM x 10-2 ft3 x 10-1 ON CFM = ft3/min Window comparator mode NO OFF P-1 P-2 For water Large flow rate OUT1 Output mode Display Instantaneous flow rate l/min Cumulative flow rate l ON YES OUT2 is the

70 N 11 18 18.5 20 26 ZZ 103 132 137 156 182 NA 17 24 30 36 46 R 28 34 40 50 S 83 106 111 124 150 W 35 50 50 50 60 X 19 25 30 40 40 Model 12-CY3B15 12-CY3B20 12-CY3B25 12-CY3B32 12-CY3B40 P (Piping port) Model Mounting nuts (2 pcs.) are shipped together.

Set value (Threshold value) Hysteresis value Main screen Measured value (Current pressure value) Peak value Left side Right side Bottom value Sub screen Label (Display item), Set value (Threshold value) Channel display V Differential Pressure Check Mode p. 2 V Input Range Selection p. 3 V 3 channels are displayed simultaneously. p. 2 V Hub Function p. 4 Compatible Convert analog signals to

For subsonic range Where P1 + 0.1013 = (1 to 2) (P2 + 0.1013) Formula based on Cv factor Q = 197.8Cv P (P2 + 0.1013) kg/h Formula based on effective area Q = 11.0S P (P2 + 0.1013) kg/h [650] (133) 0.2 [646] (120) 0.1 S = 2.8mm S = 5.9mm S = 9.2mm S = 11.7mm S = 6.3mm S = 9.7mm S = 14.4mm S = 10.8mm S = 15.3mm S = 24.8mm Flow rate Q kg/h VCS212 VCS213 VCS214 VCS215 VCS 13 VCS314 VCS315

(Not including sensor accuracy), Response time: 150 ms or less Accuracy (To display value) (25C) 1.0% F .S. or less 1.5% F .S. or less 2.0% F .S. or less PF2 0.5% F .S.

Unit switching Real-time switch output ( ) For air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES CFM x 10-2, CFM x 10-1 ft3 x 10-1 OFF P-1 P-2 High flow rate CFM=ft3/min "P" Window comparator mode H : Hysteresis High Flow Rate Type (For Air) H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON NO OFF P-1 P-2 ft3, ft3 x 103, ft3 x 106 CFM

(initial value) 1 (P) 5 (R1) 3 (R2) 3 position pressure center (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 2 Series VQ7-6 DIN Connector Type 2 position/Single : VQ7-6-FG-S Single (reverse pressure): VQ7-6-YZ-S 50 68.5 52 120.5 68.5 120.5 2-6.5 Mounting hole 50 25 25 42.5 42.5 13 (port A) 13 (port B) 3-Rc3/8 (R1, R2) Manual override R1 R2 P B A 14 50 62 11 9 12 38 50 62 13 A B R1 R2 P 2-Rc1/8 13 34 Indicator

wire Connector Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Grommet 2-wire 12 V Connector Relay, PLC 24 V 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color indication) 5 V, 12 V Grommet 2-wire 12 V Water resistant (2-color indication) With diagnostic output (2-color indication) 5 V, 12 V IC circuit 4-wire (NPN

C76 Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL C85 C95 CP95 Auto Switch Mounting Bracket Part No.

Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-11 Connection of RS-232C 3.3 Installation HRS Series 3-16 HRX-OM-O021 Chapter 3 Transport and Setting Up 3.4 Piping Connect piping firmly.

12 V Relay, PLC Grommet Yes 24 V 3-wire (NPN) 5 V, 12 V IC circuit Diagnostic indication (2-color indication) 3-wire (PNP) 2-wire 12 V Yes No Yes No 100 V Reed auto switch Relay, PLC IC circuit 100 V or less Grommet 24 V 2-wire 12 V 100 V, 200 V 200 V or less Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid

Data Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL Auto Switch Mounting Bracket Part No.

Data Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL Auto Switch Mounting Bracket Part No.

Data Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL Auto Switch Mounting Bracket Part No.

IS1000-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Differential 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V 24 V Voltage (AC, DC) 50 mA 40 mA 20 mA 50 mA Max. current 1.2 ms Operating time 30 G Shock resistance JIS Symbol AMR5100 AMR4000 AMR3000 14-7-1 2 Series AMR3000 to 6000 How to Order E3 03 R S AMR 4 0 00 Adapter Assembly (Part

(Tightening torque of M2.5 screw should be 0.1 to 0.2 Nm.) 20 Reed switchD-A90(V)/A93(V)/A96(V) Solid state switchD-M9N(V)/M9P(V)/M9B(V) F9NW(V)/F59W/F9BW(V) F9BAL Data Auto Switch Mounting Bracket Part No.

(Values at the initial period) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 3 position pressure center (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 3-10-7 8 Series VQ7-6 DIN Terminal Type 2 position single : VQ7-6-FG-S single (Reverse pressure): VQ7-6-YZ-S 120.5 120.5 68.5 52 68.5 Mounting hole 2-6.5 50 50 42.5 42.5 25 25 13 (A port) 13 (B port) Manual override (R1, R2) 2-3/8 P R2 R1 A B 14 11 50 62 12 9 62