SMC Corporation of America
Elite Part Number Search
Search Results "ISE20CH-V-F02L-A3"

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: w/o Operation

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover,

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: w/o Operation Manual,

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation Manual: w/o Operation Manual

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: w/o Operation

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover,

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: w/o Operation Manual,

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3-Screen High Precision Dig Press Switch, PRESSURE SWITCH, ISE1-6, N59, 74 lb

Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: w/o Lead Wire, Bracket: A3 (Bracket C)

Rated Pressure Range: -0.1 to 2 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: w/o Lead Wire, Bracket: Bracket C, Operation Manual: -

(5.7) 15 16 11 30.7 114 [820m] A B-1 2 A A-1 1 L B B-2 6 B A-2 5 8 8m COM-A/COM B-3 3 COM-B/ A-3 4 A 10m B 15m Shield Vcc B-4 12 C 20m GND A-4 13 A B-5 7 A A-5 6 B B-6 9 B A-6 8 3 4 B-1 5 A-1 1 B-3 2 A-3 2 1 (5.5) 14 18 (6.3) B1 A1 5 6 17.7 14.2 A6 B6 B1 A1 10.2 2 1 B3 A3 (5.7) 15 16 11 30.7 45 - 115 I/O No.

D-A5/A6 D-A59W D-B5/B6/B59W D-A3C D-G39C/K39C D-A3 D-G39/K39 D-G5/K59 D-G5W/K59W D-G5BAL D-G59F/G5NTL D-F5/J59 D-F5NTL D-F5W/J59W D-F5BAL/F5F D-A44 D-A44C Setting Position of Auto Switch (mm) Mounting Height of Auto Switch (mm) D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-A5,A6 D-A3,A3C D-B5,B6 D-G5W D-K59W D-G5BAL D-G59F D-G5 D-K59 D-G5NTL

D-A44 D-A44C Setting Position of Auto Switch (mm) Mounting Height of Auto Switch (mm) D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-G5 D-K59 D-G5NTL D-F5 D-J5 D-B5, B6 D-B59W D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G5BAL D-G59F D-A5,A6 D-A3,A3C D-B5,B6 D-G5W D-K59W D-G5BAL D-G59F Model D-F5W D-J59W D-F5BAL D-F59F D-A3C D-G39C D-K39C D-A44C D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W D-A44,A44C D-A59W

D-G5NTL 75 + 50 (n-2) 15 75 30.5 38 43 50 A B 0 (1) 0.5 2 2 D-A3 D-G3, D-K3 100 + 100 (n-2) 35 + 30 (n-2) 35 100 D-B5, D-B6 33.5 23.5 25 25 Approx. Hs 25.5 (28.5) 38 43.5 50.5 D-A4 35 + 30 (n-2) 50 + 50 (n-2) 35 55 A B 0 2 3.5 3.5 D-G5NTL 27 25 26.5 26.5 Approx. Hs 33.5 38 43.5 50.5 A B 0 1.5 1.5 D-A3 D-G3, D-K3 23 24.5 24.5 Approx.

Do not indicate lead wire length symbol N (none) for types D-A3, D-A44, D-G-39 or D-K39. Lead wire length symbols: 0.5m . Nil (Example) C73C 3m . L (Example) C73CL 5m . Z (Example) C73CZ None .

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)