Description Body Note Baking finish Material q Aluminum alloy w w Aluminum alloy Baking finish Housing e Aluminum alloy Baking finish Drain guard y r Foam rubber Float IN t Stainless steel + Rubber Pilot valve y Resin Lever u Brass Flushing button t i Orifice r o Rubber Diaphragm Replacement Parts 10-1 e No. Description Part no. ADH-D400 Note 10-2 !

9 @0 @1 @2 @3 @4 No. q w e r t y u i o !0 !1 !2 !3 Steel wire Chrome-molybdenum steel Steel Resin Urethan rubber NBR NBR NBR NBR NBR Rod cover Head cover Cylinder tube Piston rod Piston Cushion ring A Cushion ring B Bushing Cushion valve Snap ring Tie-rod Tie-rod nut Piston nut Replacement Parts: Seal Kit Bore size (mm) Kit no.

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)

Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: None, Operation Manual/Calibration Certificate: Y (None)

For vacuum/ compound pressure ISA2 ZSE30A 01 N M Option 3 Note) Calibration certificate Nil Y K T Note) Operation manual ISE35 Symbol Rated pressure range ZSE30A ZSE30AF 0 to 101 kPa 100 to 100 kPa PSE Piping specifications IS 01 Note) All texts in both English and Japanese.

Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: None

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket B, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -