Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: None (Straight), Port Size: F1 (G1/8), Output Specification: L (Out 1: IO-Link or NPN/PNP)
Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: None (Straight), Port Size: F1 (G1/8), Output Specification: L2 (Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input)
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: L (No Flow Adjustment Valve, Rear Ported), Port Size: F1 (G1/8), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve)
Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: F1 (G1/8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V)
Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: F1 (G1/8), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve), Calibration Certificate
Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: F1 (G1/8), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: F1 (G1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve), Calibration Certificate: A (Calibration
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: F1 (G1/8), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: None (Straight), Port Size: F1 (G1/8), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate), Made to Order: X731 (Compatible with Argon and Carbon
Rated Flow Range: 02 (0.02 to 2 L/min), Flow Adjustment Valve: None (Straight), Port Size: F1 (G1/8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V)
Rated Flow Range: 02 (0.02 to 2 L/min), Flow Adjustment Valve: None (Straight), Port Size: F1 (G1/8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector)
Please contact us for the latest version.sales@ocaire.com, BONNET ASSEMBLY *LQA, AIRLINE EQUIPMENT, AR MASS PRO, F1, AR MASS PRO 1/2 PART, .11997 lb, Regulator Series ARPages 346 through to 355ModelPort sizeOptionsRegulator Series ARPages 346 through to 355AR401/4, 3/8, 1/2BracketSquare embedded type pressure gauge (except the AR10)Round type pressure gauge Digital pressure
Please contact us for the latest version.sales@ocaire.com, BONNET ASSEMBLY, AIRLINE EQUIPMENT, AR MASS PRO, F1, AR MASS PRO 1/2 PART, .11997 lb, Regulator Series ARPages 346 through to 355ModelPort sizeOptionsRegulator Series ARPages 346 through to 355AR401/4, 3/8, 1/2BracketSquare embedded type pressure gauge (except the AR10)Round type pressure gauge Digital pressure switch(except
Please contact us for the latest version.sales@ocaire.com, MAINTENANCE KIT, VALVE, PA PROCESS PUMPS, F1, PA BODY PORT 1/4, .06613 lb
Please contact us for the latest version.sales@ocaire.com, MAINTENANCE KIT, VALVE, PA PROCESS PUMPS, F1, PA BODY PORT 1/4, .06613 lb
Please contact us for the latest version.sales@ocaire.com, MAINTENANCE KIT, VALVE, VX2 2-WAY MEDIA VALVE, F1, VX2 BODY PT 1/4, 1.10971 lb
Operating equipment: MHC2-6D A part a b c d e f = 20 (mm) = 3 (mm) = 4 (mm) = 4 (mm) = 5 (mm) = 6 (mm) b c a e B part f d z f1 x.Calculate the inertial moment of the attachment. Assuming the attachment material is aluminium alloy (relative density=2.7), r1= 16.4 (mm).
Use this box ior inductive loads, 5 metersor more ol lead wires, or 100,200VAC applica" D-48 swlch is used iof IooVAC or lsss Sin@ lhere F no votage lmilalon, you can s 6ct a suilable model lor your 2 AND connections for 2-wire system 2 OR connctions lor 2-wire system -go-f1;rw el rwo >w !r e\ " f = ; C ; i r _ , i o q m l r a 6 d . t o a d J o r . \\.:j+_ | aq6 oe.orr qredrasa I | -!
NO.ZK2-OM00801-B // ZK2-ZSV-A A 2 9 10 11 14 14 15 16 16 17 17 20 20 20 F0 22 F1 OUT1 23 F2 OUT2 25 F3 27 F4 28 F6 30 F11 31 F80 32 F81 33 F90 34 F96 36 F98 37 F99 39 40 B 43 44 45 51 52 52 -1NO.ZK2-OM00801-B (ISO/IEC)(JIS)1)2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems.
Number ZK2-ZSV#-A-X188 Table of Contents Safety Instructions 2 Model indication and How to order 9 Summary of Product parts 10 Definition and terminology 11 Wiring 15 Wiring 15 Internal circuit and wiring example 16 Mounting and Installation 17 Installation 17 Easy Setting 18 Measurement mode 18 Function Setting 22 Function selection mode 22 Default setting 22 F0 Unit selection function 24 F1