SMC Corporation of America
Elite Part Number Search
Search Results "LVM10R4Y-6F2-1-KO"

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PFA; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PFA; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PFA; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: Manual Override, Lead Wire Length: 300mm, CE Compliant: CE Compliant

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PFA; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: Bracket + Manual Override, Lead Wire Length: 1000mm, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PFA; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: Bracket + Manual Override, Lead Wire Length: 600mm, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PFA; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PFA; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PFA; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: Bracket + Manual Override, Lead Wire Length: 300mm, CE Compliant: CE Compliant

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PFA; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: None, Lead Wire Length: 600mm, CE Compliant: CE Compliant

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PFA; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: None, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PFA; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: None, Lead Wire Length: Plug Connector, 300mm, CE Compliant: CE Compliant

Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C

Inscribed number 3 3 x 1 3 3A 1/8" x 1/16" 4 4 x 2 4 4A 5/32" x 1/32" 6 6 x 4 6 6A 1/4" x 1/8" KO Plug connector, Without connector G (Option) Grommet, 300 mm y Lead wire length Nil 300 mm 6 600 mm 10 1000 mm The plug connector is included but does not come assembled.

Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C

Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C

Series LVM is a compact, direct acting, 2/3 port solenoid valve for chemicals. The unique construction reduces residual liquid to a minimum. Superior resistance to chemicals requires less maintenance. Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C

Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PFA; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant

Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PFA; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PFA; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PFA; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: Bracket + Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: CE Compliant