If there is vibration, impact, etc. at long stroke, we recommend adoption of side support even if it is within the allowable value shown in the graph. 400 W l Load W ML2B32 W (1200) (1200) 300 ML2B25 l l 200 100 0 1000 2000 (mm) Support spacing l 10-13-16 14 Stroke Reading Rodless Cylinder with Brake Series ML2B Proper Auto Switch Mounting Position (Detection at stroke end) Operating Range
If there is vibration, impact, etc. at long stroke, we recommend adoption of side support even if it is within the allowable value shown in the graph. 400 W l Load W ML2B32 W (1200) (1200) 300 ML2B25 l l 200 100 0 1000 2000 (mm) Support spacing l 10-13-16 14 Stroke Reading Rodless Cylinder with Brake Series ML2B Proper Auto Switch Mounting Position (Detection at stroke end) Operating Range
Function Coil voltage Symbol Specifications DC (1.0 W) AC 1 2 3 4 5 6 9 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other (3) Nil Standard type High pressure type (Metal seal only) (1.0 W) (1) K (0.5 W) Low wattage type Y External pilot type (2) R Note) Note 1) Option Note 2) For details about external pilot specifications, refer to page
40 Work load: W [kg] Work load: W [kg] 20 Lead 16: LEKFS32EA 30 Lead 16: LEKFS32EA 20 Lead 24: LEKFS32EH 10 Lead 24: LEKFS32EH 10 0 0 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 Speed: V [mm/s] Speed: V [mm/s] Vertical LEKFS40/Ball Screw Drive Horizontal 70 60 30 Lead 10: LEKFS40EB Lead 10: LEKFS40EB Work load: W [kg] Work load: W [kg] 50 40 20 Lead 20: LEKFS40EA 30 Lead 30: LEKFS40EH
3 w @4 @3 !6 !7 !8 !1 @1 !2 q @0 u !
1 Drain q r e w t i u y o !0 !
Note 2) Without valve mechanism. q 00 10 20 30 40 e w w q w q q w e q w (1) Numbers in K indicate the constructing order from the left hand side (upper stream) with a view from front. Ex.) Symbol 00 AF+AR+AL 10 AW+AL (Available only for AC1010 to 4010.) 20 AF+AR 30 AF+AFM+AR (Available only for AC2030 to 4030.)
0 50 100 150 Flow rate L/min (ANR) Flow rate L/min (ANR) Condition: Inlet pressure 0.7 MPa ARM11AA1-310-1 (One-touch fittings: IN 8, OUT 6) Condition: Inlet pressure 0.5 MPa ARM11AA1-310 (One-touch fittings: IN 8, OUT 6) 0.35 0.7 0.6 0.30 Outlet pressure (MPa) Outlet pressure (MPa) 0.5 0.25 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0.00 0 0 50 100 150 200 0 50 100 150 200 250 300 Flow rate L/min
M40 X 1.5 Lube Non-lube 3/4 1 M20 X 1.5 50 to 1200 90 115 18.5 20 46 226 182 17 60 50 48 44 63 25 74 39 40 100 M45 X 1.5 M24 X 1.5 63 to 1200 140 23 25 56 110 277 225 67 60 60 20 55 71 30 86 49 50 126 M56 X 2 1 M30 X 1.5 80 to 1200 65 140 23 30 130 330 270 80 76 37 70 96 60 20 49 68 63 160 M64 X 2 With auto switch/125 to 200 only (mm) W/o rod boot W/rod boot (mm) W/o rod boot W/ rod boot
However, if there is any problem, use a 3 wire DC style. 3.8-11 Series CXT Auto Switch Mounting Position and Mounting Height Reed switch Solid state switch A B W D-F9NW D-F9PW D-F9BW D-A90 D-A93 D-A96 D-F9N D-F9P D-F9B D-F9BAL 12 A B W 16, 20, 25 W A B 32, 40 (mm) D-A90 D-A93 D-A96 D-F9NW D-F9PW D-F9BW D-F9N D-F9P D-F9B Auto switch model D-F9BAL Symbol A B W A B W A B W Standard stroke 12
Relay, PLC 100 V Reed switch Solid state switch PLC 100 V, 200 V Relay, PLC 12 V Yes Yes 24 V 2-wire Terminal conduit PLC 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) 5 V, 12 V 24 V IC circuit Grommet 100 V, 200 V 2-wire 12 V IC circuit 3-wire (NPN) 2-wire Terminal conduit 5 V, 12 V Relay, PLC 12 V 3-wire (NPN
SW Enable SW SW 12 Unit name W 1 W-AREA1 W 1 AREA ON (mm) W 12 AREA ON + *W 1>=W 2 ,PARA W 1=W 2=0 AREA OFF W 2 W-AREA2 W 2 + ORG Correct * Sensor type * 1 (CC-Link () 1 (CC-Link ) ) () Option 1 1 (1 ) 14 (Occupied number of stations of CC-Link) 2 (2 ) 4 (4 ) CC-Link (CRC ) 11 CC-Link 11 CC-Link CC-Link 0 () UndefineN o.11 0,10 (Operation setting at CC-Link communication
speed should be 100 to 200mm per second.
or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less Between case and AC line: 1500 VAC for 1 min.
mA Residual voltage: 1 V or less (Load current: 100 mA) Maximum applied voltage: 26.4 VDC Maximum load current: 100 mA Residual voltage: 1 V or less (Load current: 100 mA) Maximum applied voltage: 26.4 VDC Maximum load current: 100 mA Residual voltage: 1 V or less (Load current: 100 mA) Error signal Maximum load current: 100 mA Residual voltage: 1 V or less (Load current: 100 mA) Output
With Auto Switch, Super Compact Allowable lateral load at rod end (Double acting, Single rod, Without auto switch) Allowable lateral load at rod end (Double acting, With switch, Super compact) Allowable lateral load at rod end (Double acting, With switch) 100 100 100 Allowable lateral load for rod end: W (lbf) Allowable lateral load for rod end: W (lbf) Allowable lateral load for rod end
Retraction locking: B Extension locking: F CL W CL1 B A MLGC Emergency stop Drop prevention A W B CNG W MNB Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CNA W CNS W CLS CLQ MLGP W RLQ W MLU ML1C W DPreparing for Operation Warning 1.
-11-R1-100-MW 3/8" Polyurethane Tubing 100 ft. - Red TIUB-01-W-50-MW 1/8" Polyurethane Tubing 50 ft. - White TIUB-01-W-100-MW 1/8" Polyurethane Tubing 100 ft. - White TIUB-03-W-50-MW 5/32" Polyurethane Tubing 50 ft. - White TIUB-03-W-100-MW 5/32" Polyurethane Tubing 100 ft. - White TIUB-07-W-50-MW 1/4"
-11-R1-100-MW 3/8" Polyurethane Tubing 100 ft. - Red TIUB-01-W-50-MW 1/8" Polyurethane Tubing 50 ft. - White TIUB-01-W-100-MW 1/8" Polyurethane Tubing 100 ft. - White TIUB-03-W-50-MW 5/32" Polyurethane Tubing 50 ft. - White TIUB-03-W-100-MW 5/32" Polyurethane Tubing 100 ft. - White TIUB-07-W-50-MW 1/4"