(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) Note 2) Impact resistance: No malfunction occurred when it was tested in the axial direction and at right angles to the main valve and armature in both energized and de-energized states once for each condition.
Note Conductor resistance /km, 20C 65 or less 1.5 m 3 m 5 m AXT100-DS25-015 Cable 25 cores x 24AWG AXT100-DS25-030 Withstand limit VAC, 1 minute 1000 AXT100-DS25-050 For other commercial connectors, use a 25 pin type with female connector conforming to MIL-C24308. Insulation resistance Mkm, 20C 5 or less Note) The minimum bending radius of the D-sub connector cable is 20 mm.
(Coil temperature: 20C, at rated voltage) 10-SY3000 10-SY7000 With light/surge voltage suppressor Response time (ms) (at the pressure of 0.5 MPa) With light/surge voltage suppressor Response time (ms) (at the pressure of 0.5 MPa) Actuation type Without light/surge voltage suppressor 12 or less Actuation type Without light/surge voltage suppressor 31 or less Type R, U Type S, Z 12 or less
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Note 2) Impact resistance: No malfunction occurred when it was tested in the axial direction and at right angles to the main valve and armature in both energized and de-energized states once for each condition.
The resistance of the solenoid valve is R 20 + 278 3% Ohm at 68F (20C). Do not bend or pull cables repeatedly. T4 Maximum surface temperature 275F (135C) Temperature class Hazardous Locations Specifications Terminal type (TT) L-type plug connector (L) LL-type plug connector (LL) Warning Electrical entry Note) 1.
Maximum Flow Capacity of the Compressor Intake Condition under Rated Conditions Model AFF70D AFF80D AFF90D Maximum flow capacity/Compressor intake condition*2 [m3/min] 7.3 11.5 15.1 *1 Flow at 20C, atmospheric pressure, and 65% of relative humidity *2 32C, flow rate when converted to atmospheric pressure *3 Filtration efficiency for the conditions below in addition to the rated conditions
Burst pressure Note) Min. bending radius (mm) 24 Burst pressure (MPa) Operating temperature Material 20C to 60C Nylon 12 Note) The value at temp. of 20C and with O.D. variable rate 10% max.
servo motor (100/200 VAC) Encoder Incremental 17-bit encoder (Resolution: 131072 p/rev) Horizontal 45 65 Power consumption [W] *5 Vertical 145 175 Horizontal 2 Standby power consumption when operating [W] *6 Vertical 8 Max. instantaneous power consumption [W] *7 445 724 Type *8 Non-magnetizing lock specifications Lock unit Holding force[N] 131 255 157 308 197 385 Power consumption [W] at 20C
O.D. 1/8" 5/32" 5/32" 3/16" 1/4" 5/16" 3/8" 3/8" 1/2" 1/4" 5/16" 3/16" 1/4" 1/8" 5/32" Inch size 3/8" 5/16" 3/16" 1/4" Flow Direction Symbols on Body Meter-out type Meter-in type Flow rate (l/min (ANR)) Controlled flow (Free flow) 100 180 230 260 390 460 660 790 920 1580 1710 Symbol Effective area (mm2) 1.5 2.7 3.5 4 6 7 10 12 14 12 26 Note) Flow rate values are measured at 0.5 MPa and 20C
Symbol Proportional Solenoid Specifications Max. current 1A VEA250,VEA251 Applicable power amplifier 13W(20C, With maximum current) 13(20C) Coil resistance Rated power consumption Class H or equivalent (180C) Coil insulation 140C(With maximum current) Max. temperature rise DIN terminal Electrical entry Manifold Accessory Mounting screw (With washer) M5 X 45 VER2000 VER4000 Model AXT500-13
Burst pressure 25 20C to 60C Nylon 12 Min. bending radius (mm)(1) Operating temperature Material Note 1) The value at temp. of 20C and with O.D. variable rate 10% max.
Note 2) The data for l/min (ANR) refers to the conditions of 20C, 1 atm. pressure and relative humidity of 65%. Note 3) Install a circuit breaker with sensitivity of 30mA.
(mm) 4 6 8 10 12 3.18 4.76 6.35 9.53 12.7 2.5 4 5 6.5 8 2 3.18 4.23 6.35 8.46 Black (B) White (W) Red (R) Blue (BU) Burst Pressure Characteristics Curve Yellow (Y) Green (G) Clear (C) Orange (YR) Nominal size (inch) 5 32 " 5 16 " 1 4 3 8 " 3 16 " 1 8 " 1 2 " " Specifications Fluid Air, Water Max. operating pressure 0.8MPa at 20C Refer to pressure characteristics curve.
N) 17 Double acting Single acting 6 115 30 16 40 MHZ2-16D (N) 10 235 42 20 66 MHZ2-20D (N) Single acting type, normally open 14 430 65 25 104 MHZ2-25D (N) 4 55 6.3 10 MHZ2-10S (N) Normally closed Normally open 6 115 24 16 MHZ2-16S (N) 10 240 28 20 MHZ2-20S (N) 14 435 45 25 MHZ2-25S (N) 12 4 55 10 MHZ2-10C (N) 31 Single acting type, normally closed 6 115 16 MHZ2-16C (N) 56 10 240 20 MHZ2-20C
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
Item Conductor resistance /km, 20C Characteristics Cable length (L) Assmbly part no. Note Connector manufacturers example Hirose Electric Co., Ltd. Sumitomo 3M Limited Fujitsu Limited Japan Aviation Electronics Industry, Ltd. J.S.T. Mfg.
(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Made to Order Specifications (For details, refer to page 3-6-11.)
Membrane Dyer Series IDG Standard specifications/Single style (standard dew point 20C (4F)) Model Standard dew point 20C IDG5 IDG10 IDG20 IDG30 IDG50 Fluid Compressed air Macromolecular membrane dryers that act like filters Range of operating conditions Standard performance conditions Inlet air pressure MPa (psi) 0.3 to 0.85 (43 to 123) 0.3 to 1.0 (43 to 145) Inlet air temperature C (F) Note