Dynamic moment Me3 We W L2 Review Me3. = 1/3 14.7 (50 + 27) 103 = 0.38 [Nm] 3a = Me3/Me3 max = 0.38/3 = 0.13 Central axis of guide A Me1 W We Me1 = 1/3 We(L1 + B) 103 = 1/3 14.7 (50 + 48) 103 L1 B = 0.48 [Nm] 3b = Me1/Me1 max = 0.48/3 = 0.16 Review Me1.

Dynamic moment Me3 We W L2 Review Me3. = 1/3 14.7 (50 + 27) 103 = 0.38 [Nm] 3a = Me3/Me3 max = 0.38/3 = 0.13 Central axis of guide A Me1 W We Me1 = 1/3 We(L1 + B) 103 = 1/3 14.7 (50 + 48) 103 L1 B = 0.48 [Nm] 3b = Me1/Me1 max = 0.48/3 = 0.16 Review Me1.

1Tank pressure gauge 272 272 153 238 153 238 e e 189.5 153 2 189.5 2 u u w r i w r i o o Material Note Main Parts List Part no. Spare Parts/Replacement Parts Part No. No. Description No. Qty.

or less Current type IR Input impedance Approx. 6.5k Voltage type Straight type Right angle type Approx. 2.7k Preset input VEX 1 to 5V DC (load impedance: 1k or more) 4 to 20mA (sink type) (load impedance: 250 or less) Analog output (2) AW Output signal (monitor output) Switch output NPN open collector output: Max. 30V, 30mA PNP open collector output: Max. 30mA AMR Symbol Linearity Within

0 Socket head cap screw 105 C CKZN-D050 Note 2) 120 B w Stopper bolt r Bumper !1 Seal washer 135 A 50 CKZN-B050 Note 2) CKZN-D050 CKZN-B050 CKZN-K050 Note 2) q Switch actuator o Spring washer !0 Socket head cap screw CKZN-D063 Note 2) Kits for changing opening angle of arm w Stopper bolt r Bumper !

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Leakage test result a t e l u g c Stainless steel linear guide & low particulate generation vacuum grease e i 2 t n r a e CX p r a 0.0 10 0 20 10 w 10-10 0 5 10 t i o o n L DTime [min] Operation cycles -X e e a a l l k k a t e l u w w g a a c 2 e i o

Cam Lever NVM121-NO1-02 = z-wayi 2 porl-lh" NPT w/One Way Cam Lever NVM131-N01-01 : 3-way; 2 porl:/e" NPT w/Std.

Lead wire color *1 q q DC (+) 1 Brown w N.C./IN 2 Not used e DC () 3 Blue r INPUT 4 White (Flow sensor 1 to 5 V input) e w 1 2 3 4 r *1 When using the lead wire and M12 connector included with the LFElJ series. Do not connect black. Power supply/output connection lead wire Cable Specifications Pin no.

DC (42 mA), 0.5 W DC (21 mA) (4) 24 VDC Power consumption (Current) 1 W DC (83 mA), 0.5 W DC (42 mA) (4) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 12 VDC Metal seal Rubber seal Note 1) Use dry air to prevent condensation when operating at low temperatures.

5For PROFIBUS DP K w For EtherNet/IPTM, PROFINET, EtherCAT, Ethernet POWERLINK K w and K e are used in combination with each other. K !7For PROFIBUS DP For DeviceNetTM (Plug) For PROFIBUS DP (Plug/B-coded) Plug (Male) K q For EtherNet/IPTM, PROFINET, EtherCAT, Ethernet POWERLINK RJ45 VProduct Table Description Application No. SMC part no.

For each additional input block, add 21mm.) n: Stations (maximum 24 stations) n L L1 L2 L3 L4 1 55.5 178 200 210.5 2 66 188.5 212.5 223 3 76.5 199 225 235.5 4 87 209.5 237.5 248 5 97.5 220 250 260.5 6 108 230.5 250 260.5 7 118.5 241 262.5 273 8 129 251.5 275 285.5 9 139.5 262 287.5 298 10 150 272.5 300 310.2 11 160.5 283 312.5 323 12 171 293.5 325 335.5 13 181.5 304 325 335.5 14 192 314.5

Relief valve 0 1 2 N W V Petroleum Water-glycol, Emulsion Phosphoric ester The micromesh element is a made to order specification (X0).

Cam Lever NVM121-NO1-02 = z-wayi 2 porl-lh" NPT w/One Way Cam Lever NVM131-N01-01 : 3-way; 2 porl:/e" NPT w/Std.

Note) If the set pressure is 250 kPa and the output pressure on the pressure sensor is 245 kPa, the deviation is 250 245 = 5 kPa. In order to correct the deviation, the controller increases the output signal until the pressure on the pressure sensor converges at 250 kPa. Step 1 Step 2 Step 3 Step 4 . . . . . . . . . . . . .

Standard Strokes Bore size [mm] Standard stroke [mm] Max. manufacturable stroke 32 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 45 25, 50, 75, 100, 125, 150, 175, 200, 250, 300 300 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 56 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 400 63 25, 50, 75, 100, 125, 150

Annual cost reduction effect [Calculation conditions] Electric power cost: 1.55 yen/m3 [Work model] Working hours: 6000 h (250 days/year) Supply pressure: 1.0 MPa Set pressure: 0.2 MPa Comparison between IR3000-A and the current IR3000 Comparison between IR1000-A/IR2000-A and the current IR1000/IR2000 300 300 Annual cost of power consumed by compressor [1000 yen/year] 250 250 When 20 units

Note AM IDG30/30H/30L IDG50/50H/50L IDG60/60H/60L/60S IDG75/75H/75L/75S IDG100/100H/100L/100S q w e r t Body Aluminum alloy Platinum silver coated Misc. Case Stainless steel Orifice Stainless steel Holder Aluminum alloy Aluminum Silencer Resin + Copper alloy Replacement Parts Part no. No.

LED level meter Easy-to-operate large dial Above set position Set position Below set position Red Green Green Extraneous material W W W Scale provides guidelines for set position. 2 wiring methods Centralized Wiring Individual wiring Minimum operating pressure 30 kPa (ISA2-G) Energy consumption can be reduced compared with the conventional models (Conventional models: 50 kPa) Position of

x10 12REA 50/63 0 -0.2 L NA 33 2-Rc, NPT, G 1/4 14 14 E(h8) E(h8) X D I 4-TC 14 14 Effective thread depth R 23 22 K W 23 25 2 4-M8 x 1.25 25 8-Q 14.5 C 0.1 + Effective thread depth 12 Effective thread depth R B S + Stroke 2 ZZ + Stroke Q x R S TC x R Model L 122 110 K 38 32 C 70 60 X ZZ NA E D B 72.2 58.2 I 70 60 W 12-REA63 12-REA50 100 86 66 53 30-0.033 69 55 M10 x 1.5 x 16 M8 x 1.25 x