Series: Standard, Mounting: MP2, Detachable Rear Clevis, Bore Size: 3 1/4", Stroke: 1", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder
Series: Standard w/ Magnet, Mounting: MS1, Foot, Bore Size: 5" - Large Bore, Stroke: 1", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod
Series: Standard, Mounting: MX0, Basic, Bore Size: 5" - Large Bore, Stroke: 1", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder
Series: Standard, Mounting: MF2, Rear Flange, Bore Size: 5" - Large Bore, Stroke: 1", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder
Series: Standard w/ Magnet, Mounting: MS4, Side Tapped, Bore Size: 2 1/2", Stroke: 1", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder
Series: Standard, Mounting: MF1, Front Flange, Bore Size: 5" - Large Bore, Stroke: 1", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder
Series: Standard, Mounting: MX0, Basic, Bore Size: 6" - Large Bore, Stroke: 1", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder
Series: Standard, Mounting: MP1, Double Rear Clevis, Bore Size: 4", Stroke: 1", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder
Series: Standard, Mounting: MF1, Front Flange, Bore Size: 6" - Large Bore, Stroke: 1", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder
Modbus RTU protocol (Hexadecimal notation) Request data 01 08 0 1234 ED7C Response data (normal response) 01 08 0 1234 ED7C (Binary notation) Response data 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 Response data (normal response) 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 For correspondence between ASCII notation and ASCII hexadecimal notation, refer to the 8.4 ASCII
Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.
Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.
Center trunnion style, Foot style Rod side flange style NCA Foot style Rod side flange style Bore size (mm) DMade to Order Specifications (For details, refer to page 6-17-1.) 125 1000 or less 1000 or less 1600 or less -X 140 1000 or less 1000 or less 1600 or less Symbol Specifications 160 1200 or less 1200 or less 1600 or less 20-XA Change of rod end shape 180 1200 or less 2000 or less -XB5
Dimension changes for Options Oversized rod (XB5 Option) Rotated Ports (XC3 Option) Port standard location Head end KK MM B Rod end Cushion location standard WF ZJ + Stroke A How to Order: -XC3 Port Cushion Standard Part Number Location.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Example: Part Number *NVSA 4114-52AM =A |NVSA 4114.00A vatve mounled on *ISPA 0112 subplate with a #SPA 0100 Interlace Spaed Control between.
[PA04] = 0100. Set the "PA04" to "0100" in the "Basic" tab. Click on the "Single Axis Write" button. Turn the power OFF and ON again. Parameter is enabled. -24- 6.3.6 Absolute position detection system *If you use the absolute position detection system, set parameter: [PA03]=0001. Refer to "LECSS Operation Manual, chapter 12 for details.