SMC Corporation of America
Elite Part Number Search
Search Results "PF2M702-F1-E"

Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: F1 (G1/8), Output Specification: L4 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: None (Straight), Port Size: F1 (G1/8), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA)

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: None (Straight), Port Size: F1 (G1/8), Output Specification: L (Out 1: IO-Link or NPN/PNP)

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: None (Straight), Port Size: F1 (G1/8), Output Specification: L2 (Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input)

Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: L (No Flow Adjustment Valve, Rear Ported), Port Size: F1 (G1/8), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve)

Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: F1 (G1/8), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve), Calibration Certificate

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: F1 (G1/8), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)

Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: F1 (G1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve), Calibration Certificate: A (Calibration

Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: F1 (G1/8), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)

Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: None (Straight), Port Size: F1 (G1/8), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate), Made to Order: X731 (Compatible with Argon and Carbon

Please contact us for the latest version.sales@ocaire.com, BONNET ASSEMBLY *LQA, AIRLINE EQUIPMENT, AR MASS PRO, F1, AR MASS PRO 1/2 PART, .11997 lb, Regulator Series ARPages 346 through to 355ModelPort sizeOptionsRegulator Series ARPages 346 through to 355AR401/4, 3/8, 1/2BracketSquare embedded type pressure gauge (except the AR10)Round type pressure gauge Digital pressure

Please contact us for the latest version.sales@ocaire.com, BONNET ASSEMBLY, AIRLINE EQUIPMENT, AR MASS PRO, F1, AR MASS PRO 1/2 PART, .11997 lb, Regulator Series ARPages 346 through to 355ModelPort sizeOptionsRegulator Series ARPages 346 through to 355AR401/4, 3/8, 1/2BracketSquare embedded type pressure gauge (except the AR10)Round type pressure gauge Digital pressure switch(except

Please contact us for the latest version.sales@ocaire.com, MAINTENANCE KIT, VALVE, PA PROCESS PUMPS, F1, PA BODY PORT 1/4, .06613 lb

Please contact us for the latest version.sales@ocaire.com, MAINTENANCE KIT, VALVE, PA PROCESS PUMPS, F1, PA BODY PORT 1/4, .06613 lb

Please contact us for the latest version.sales@ocaire.com, MAINTENANCE KIT, VALVE, VX2 2-WAY MEDIA VALVE, F1, VX2 BODY PT 1/4, 1.10971 lb

NO.ZK2-OM00801-B // ZK2-ZSV-A A 2 9 10 11 14 14 15 16 16 17 17 20 20 20 F0 22 F1 OUT1 23 F2 OUT2 25 F3 27 F4 28 F6 30 F11 31 F80 32 F81 33 F90 34 F96 36 F98 37 F99 39 40 B 43 44 45 51 52 52 -1NO.ZK2-OM00801-B (ISO/IEC)(JIS)1)2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems.

ZQ-OM01601 // ZQ-ZSV 2 9 10 11 14 14 15 16 16 19 19 19 F0 21 F1 OUT1 22 F2 OUT2 24 F3 26 F4 27 F6 29 F11 30 F80 31 F81 32 F90 33 F96 35 F98 36 F99 38 39 42 43 44 50 51 51 1 - *1) *2) (ISO/IEC)(JIS) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems. ISO 4413: Hydraulic fluid power -General rules relating to systems.

.: ZS-46-A2) F0 Function setting F1 Function setting F99 Function setting : Some products do not have all the functions. If no function is available or selected due to configuration of other functions, [-] is displayed on the sub display (right). Self tapping screws: Nominal size 3 x 8L Self tapping screws: Nominal size 3 x 8L Default setting The default setting is as follows.

F0 Function setting F1 Function setting F99 Function setting : Some products do not have all the functions. If no function is available or selected due to configuration of other functions, [-] is displayed on the sub display (right). Default setting The default setting is as follows. If no problem is caused by this setting, keep these settings.

F0 Function setting F1 Function setting F99 Function setting : Some products do not have all the functions. If no function is available or selected due to configuration of other functions, [-] is displayed on the sub display (right). Default setting The default setting is as follows. If no problem is caused by this setting, keep these settings.