F1 F 1 LLB3 Standard (100 L/min (ANR)) LLB4 High flow type (500 L/min (ANR)) F 1 Filter F With filter Port size 1 3 3N 12 One-touch fitting Rc 3/8 NPT 3/8 Restrictor Note) Use a resin fitting (no metal) for Rc and NPT thread.
F_Source/Destination_Address (F-Address) F-Source F-destination F-Address F-Address F_WD_Time F_WD_Time PROFIsafe ms F_SIL SIL F_iPar_CRC i-Prameters F_Par_CRC F-Parameters CRCF-Parameters F-CPU Failsafe controller, safe controller F_Destination_Address F-Parameter (F-Parameter) F-I/O device Failsafe I/O I/O 100 No.EX##-OMY0006CN F-Slave Failsafe slave F_Source_Address F-Parameter
MPa ZSE20 5.1 kPa ZSE20F5.0 kPa 1.5ms ON OFF -26No.PS-OMS0006CN-G [F 2] [F 3] 32 0 ms [F 4] 33 [F 5] [F 6] 35 0% [F10] 36 std() [F11] 41 1000 [F80] 42 OFF [F81] 43 OFF [F82] 45 A [F90] 46 OFF [F96] [F97] [F98] 48 () [F99] 49 OFF -27No.PS-OMS0006CN-G [F 0] (kPa/MPa) <> [F 0] [F 0] ZSE20F ZSE20 ISE20 MPa 0.001 0.001 0.001 kPa 0.1 0.1 1 2 0.001 0.001 0.01 kgf/cm bar 0.001 0.001
Current consumption Note 2) Max. 100 mA Max. 65 mA SQ Input/output specifications Number of inputs 8 4 VQ0 Number of outputs 8 4 24 VDC 10% Valve supply voltage VQ4 Possible supply current Note 3) Max. 240 mA Max. 120 mA VQ5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Port size NPT Model Model 10-32 UNF M5 3/8 1/8 1/4 1/2 3/8 1/8 1/4 1/2 AKH04 AKH06 AKH08 AKH10 AKH12 AKH03 AKH07 AKH09 AKH11 AKH13 4 6 8 10 12 5/32" 1/4" 5/16" 3/8" 1/2" From one-touch fitting to male thread B Bushing Type AKB 01 A 01 S With sealant (standard) Body size Port size 01 1/8 01 1/8 Thread type 02 1/4 02 1/4 03 3/8 Nil R 03 3/8 04 1/2 N NPT 04 1/2 Check valve free flow direction
GD Breaker Capacity and Sensitivity Current Sensitivity current IDFB4E to 37E IDFB55E, 75E Model Breaker capacity 10 A 30 mA Maximum operating pressure: 240 psi (1.6 MPa) 10 A 30 mA Replacement Parts Configuration Replacement part no.
Width across flats KB B C V MM BH1 BH2 BH3 TX D E B1 C B ZZ + Stroke S + Stroke H A K BN N1 N MA MB F AL H1 TT B C B1 C B TY With rod boot d e 10.2 f h 10.2 l [mm] Bore size A AL B B1 BH1 BH2 BH3 BN BP C D E F GA GB GC GD GE GF H H1 J 32 22 19.5 46 46 23 38.5 46.5 59 1/8 32.5 12 30 13 37.5 13 37.5 18.5 4 13 47 6 M6 x 1.0 40 30 27 57 52 28.5 42.5 48.5 73 1/8 38 16 35 13 59.5 14 44.5 19.5 4
MA B D-A9V D-F9V D-F9WV Auto switch mounting heights (mm) Bore size (mm) D-A9V D-F9V D-F9WV D-F9BAL SMC D-A90V SMC D-A90V MA MA MA 20 25 25.5 27.5 25.5 27.5 28 30 A Approx.
VX2122-02 VX2-02 VX2322-02 VX2132-02 VX2232-02 VX2332-02 VX2242-02 VX2342-02 VX2-03 VX2322-03 VX2232-03 VX2332-03 VX2242-03 VX2342-03 VX2110-01 VX2120-01 VX2130-01 VX2110-02 VX2120-02 VX2220-02 VX2320-02 VX2130-02 VX2230-02 VX2330-02 VX2240-02 VX2340-02 VX2250-02 VX2350-02 VX2260-02 VX2360-02 VX2220-03 VX2320-03 VX2230-03 VX2330-03 VX2240-03 VX2340-03 VX2250-03 VX2350-03 VX2260-03 VX2360
ZP3-T13UM;-A12-02 ZP3-T16UM;-A12-02 Mounting Adapter Part No.
ZP3-T13UM;-A12-02 ZP3-T16UM;-A12-02 Mounting Adapter Part No.
Y60 Interface G36-10-01 G36-10-01G46-10-02 G46-10-02 G46-10-02 G46-10-02 G46-10-02 G36-10-01 1.0MPa G27-10-R1 Pressure gauge (G27-10-R1)(4) G36-2-01 G36-2-01 G46-2-02 G46-2-02 G46-2-02 G46-2-02 G46-2-02 G36-2-01 0.2MPa AD43 AD43 AD44 AD44 AD44 AD44 AD44 N.O.
MA B Auto switch mounting heights D-A9V D-F9V D-F9WV (mm) Bore size (mm) D-A9V D-F9V D-F9WV D-F9BAL MA MA MA 20 25 25 27 25 27 27.5 29.5 A Approx.
Current consumption [Power supply voltage] 1.5 V Power supply voltage for sensor 40 mA maximum (100 mA maximum for the total power supply current when 4 sensors are input.)
27NO.ZL3-OM00701-A [F 3] Response time Select the response time of the switch output.
Setting of [F 3] Response time completed. 26 -
NO. ZQ-OM01501 [F 4] Auto-preset function This function calculates and sets the pressure values automatically based on the on-going operation.
www.stevenengineering.com I S E E I N S I D E F R O N T C O V E R F O R DETAILS OF YOUR LOCAL SALES OFFICE 2.64 SOLENOID VALVES SERIES (N)VZ500 H O W T O O R D E R M A N I F O L D T Y P E 20 T O P P O R T E D D I M E N S I O N S M A N I F O L D T Y P E 20 T O P P O R T E D G R O M M E T T Y P E (N)VV3Z5 20 1 N U M B E R O F S TAT I O N S T H R E A D T Y P E 02 2 Stations to 20 20 Stations
Setting of [F 4] Auto-preset completed. Press button in measurement mode to set pressure.
Port size F.R.L. body center E F F E E B C E: 4-Rc F: Without thread A D E Model Y14-M5 Y24-01 Y24-02 Y34-01 Y34-02 Y44-02 Y44-03 Y54-03 Y54-04 Applicable models AC10, AC10A, AC10B Port size M5 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 C 14 A 23 B 16 D 25 Cross interface AC20, AC20A, AC20B AC20C, AC20D AC25, AC25B, AC25C AC30, AC30A, AC30B AC30C, AC30D AC40, AC40A, AC40B AC40C, AC40D 22 40 40 40 28
ZP3-T13UM;-A12-02 ZP3-T16UM;-A12-02 Mounting Adapter Part No.