Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GA, IFW/PFW 3/4INCH PT VERSION, 1.76396
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for high temperature fluids , Integrated display type , Temperature range: 0 to 90C , Flow rate range: 0.5-4(l/min) ~ 5-40(l/min) , PNP/NPN open collector 2 outputs , Port sizes: 3/8, 1/2, 3/4, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GA, IFW/PFW 3/4INCH PT VERSION, 1.85818
Note 2)p5% F.S. (25oC reference)0 to 1 MPa1 MPa45 kPa or less at the maximum flow999999999 LBy 1 LNPN or PNP open collector output80 mA28 VDCNPN: 1 V or less (at 80 mA load current) PNP: 1.5 V or less (at 80 mA load current)0.5 s/1 s/2 sShort circuit protectionSelect from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode.0.5 s/1 s/2 s (linked
WITHIN 2% F.S. WITHIN 0.5% F.S. REPEATABILITY OUTPUT FLOW 2.8 SCFM AT 20 psi 0.2 SCFM AT 20 psi AIR CONSUMPTION 5 160 F AMBIENT AND FLUID TEMPERATURE INTRENSICALLY SAFE, CLASS DIV. 1, GRPS. ABCD NON-INCENDIVE CLASS DIV. 2, GRPS. ABCD FM IEC Exsd BT5 explosion protection HAZARDOUS DUTY PROTECTION ALUMINUM DIE CAST BODY MATERIAL 5.3 lbs.
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Integrated display type , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GA, IFW/PFW 3/4INCH PT VERSION, 1.44184 lb, ModelMeasured
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Integrated display type , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GA, IFW/PFW 3/4INCH PT VERSION, 1.44184 lb, ModelMeasured
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Integrated display type , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GA, IFW/PFW 3/4INCH PT VERSION, 1.69021 lb, ModelMeasured
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for air applications, Integrated display type, Flow rate range: 1-10(l/min) ~ 50-500(l/min), Output for display unit with or w/o analog output, Port sizes: 1/8, 1/4, 3/8, 1/2, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, GA, IF/PFA 3/4 INCH PT VERSION, .91800 lb, ModelMeasured
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for air applications, Integrated display type, Flow rate range: 1-10(l/min) ~ 50-500(l/min), Output for display unit with or w/o analog output, Port sizes: 1/8, 1/4, 3/8, 1/2, DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IF/PFA FLOW SWITCH, GA, IF/PFA 3/4 INCH PT VERSION, .91800 lb, ModelMeasured
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Integrated display type , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GA, IFW/PFW 3/4INCH PT VERSION, 1.67815 lb, ModelMeasured
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Integrated display type , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GA, IFW/PFW 3/4INCH PT VERSION, 1.77939 lb, ModelMeasured
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Integrated display type , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GA, IFW/PFW 3/4INCH PT VERSION, 1.83803 lb, ModelMeasured
Switching from real-time flow rate to accumulated flow is possible.Digital flow switch for water applications , Integrated display type , Flow rate range: 0.5-4(l/min) ~ 10-100(l/min) , Output for display unit with or w/o analog output , Port sizes: 3/8, 1/2, 3/4, 1", DIGITAL FLOW SW, INTEG SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GA, IFW/PFW 3/4INCH PT VERSION, 1.43450 lb, ModelMeasured
25 to 85C (with no freezing and condensation)NPN open collector: Maximum load current: 80 mA; Internal voltage drop: 1 V or less (with load current of 80 mA); Maximum applied voltage: 30 V; 2 outputsPNP open collector: Maximum load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA); 2 outputsNPN or PNP open collector (same as switch output)Illuminates when output
5% F.S. or less (0 to 90C, based on 25C)70 mA or less710 g1/2, 3/4Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lNPN open collector Maximum load current: 80 mA; Internal voltage drop: 1 V or less (with load current of 80 mA) Maximum applied voltage: 30 V; 2 outputsPNP open collector Maximum load current: 80 mA; Internal voltage drop: 1.5
5% F.S. or less (0 to 90C, based on 25C)70 mA or less710 g1/2, 3/4Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lNPN open collector Maximum load current: 80 mA; Internal voltage drop: 1 V or less (with load current of 80 mA) Maximum applied voltage: 30 V; 2 outputsPNP open collector Maximum load current: 80 mA; Internal voltage drop: 1.5
5% F.S. or less (0 to 90C, based on 25C)70 mA or less710 g1/2, 3/4Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lNPN open collector Maximum load current: 80 mA; Internal voltage drop: 1 V or less (with load current of 80 mA) Maximum applied voltage: 30 V; 2 outputsPNP open collector Maximum load current: 80 mA; Internal voltage drop: 1.5