AS2001F-06-X214 AS2001F-06-X214 AS3001F-08-X214 AS3001F-08-X214 10 15 20 25 32 40 50 63 AS1201F-M5-04-X214 AS1301F-M5-04-X214 RS Q G AS2201F-01-06-X214 AS2301F-01-06-X214 2.
-X 20Stop Data 10-2-11 11 Series REA Dimensions REA25/32/40 Effective thread depth J L 0 0.1 B NN G 4-MM H G 2-port size X D I NB NB T N K W N S + Stroke F NA F R ZZ + Stroke (mm) B D F G H I K L MM x J N NA NB NN Model Port size REA25 REA32 REA40 Rc 1/8 46 27.8 13 8 20.5 34 10 70 M5 x 0.8 x 8 15 30 13 M26 x 1.5 Rc 1/8 60 35 16 9 22 40 15 80 M6 x 1.0 x 8 17 36 15 M26 x 1.5 Rc 1/4 70 43 16
Ordering Example: VV307-01-052-01-F1 pc. (5 station manifolds base) V0307-1G4 pcs. DXT060-51-13A 1 pc.
mounting (For manifold) IN side port size OUT side port size D 01 02 C6 C8 N7 N9 01 02 C6 C8 N7 N9 Rc 1/8 Rc 1/4 6 One-touch fitting 8 One-touch fitting 1/4" One-touch fitting 5/16" One-touch fitting Rc 1/8 Rc 1/4 6 One-touch fitting 8 One-touch fitting 1/4" One-touch fitting 5/16" One-touch fitting F With bracket N Name plate Note) When two or more symbols are specified, indicate them alphabetically
The electrical entry port {1021VQ1000: G 1/2, 1021VQ2000: G 3/4} permits connection of conduit fittings.
The electrical entry port {1021VQ1000: G 1/2, 1021VQ2000: G 3/4} permits connection of conduit fittings.
HRX-OM-Q026 Contents Contents Chapter 1 Safety Instructions . 1-1 1.1 Before Using the Product . 1-1 1.2 Reading the Manual . 1-1 1.3 Hazards . 1-2 1.3.1 Level of hazards . 1-2 1.3.2 Definition of Serious injury and Minor injury . 1-2 1.4 Product Label . 1-3 1.5 Safety Measures . 1-4 1.5.1 Safety instructions for use . 1-4 1.5.2 Personal protective equipment . 1-4 1.6 Emergency Measures.
port (21) (21) 5-Rc 1/4, 3/8 1(P), 4(A), 2(B), 5(R1), 3(R2) port 31 31 ( ): Rc 3/8 3 position double check: VQ465 0 1 2 position double: VQ425 3 position closed center: VQ435 3 position exhaust center: VQ445 3 position pressure center: VQ455 0 1 0 1 0 10 1 G H G H G H G H 178.5 105.5 73 42.5 50 Indicator light 164.5 178.5 11 (12.5) 4(A) port 11 (12.5) 2(B) port 59 73 42.5 105.5 Indicator
2-2.7 Mounting holes Manual override M3 X 0.5 External pilot port (Only external pilot style(R)) (C4, C6) 10 (54.5) 16.6 (M5) 30 25 2.5 20 2.5 33.2 23.2 Mounting holes 4.5 29.5 10 10.8 10.8 PE port 22.2 Die cast hole Foot bracket For manifold gasket positioning 2 2 1 5 P 3 (54.5) 2-G(PF)1/16 R port Rc(PT)1/8 P port 0 1 0 1 DIN connector (Y): VQZ212 (R)wYwC4, C6, M5 L plug connector (L)
Dimensions: 10 mm Stroke (mm) A B C D F H I J Model ZPT20F10-01-A14 20 22 12.5 15.5 36 48.5 1 15 ZPT25F10-01-A14 50 25 28 ZPT32F10-01-A14 32 35 13 16 36.5 49 1 15.5 Additional Dimensions by Stroke (mm) H I J Stroke 20 +10 +5.5 0 30 +20 +15.5 50 +40 +60.5 +25 715 ZPT Series 10 13 16 40 50 J K J K ZPT F 10-0-A10 (With buffer/One-touch fitting) ZPT F 10-01-A14 (With buffer/Female thread) Applicable
Rc 1/8 Body side VZA422-P-01 M5 x 0.8 0.53 0.17 2.2 0.49 0.17 2.0 N.O. Rc 1/8 Body side VZA414-1P-01 VZA414-1P-02 VZA414-2P-01 VZA414-2P-02 VZA424-1P-01 VZA424-1P-02 VZA424-2P-01 VZA424-2P-02 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 M5 x 0.8 0.49 0.11 2.2 0.57 0.19 2.4 N.C. Sub-plate side M5 x 0.8 0.49 0.11 2.2 0.57 0.19 2.4 N.C.
5/32 inch 4 mm 6 mm 1/4 inch 5/32 inch () PBTCB156PPSO HNBR C3604( ) POMSUS304NBRC3604 SUS304NBR 24 g 34 g 36 g 27 g 28 g 29 g 30 g 30 g 36 g +39 g 0.15mm 2(AWG26) 1.0 mm (5 ) 3.5 -77No.PS-OMU0002CN-D M5 42.6 7 M50.8 3.5 01/N01 A 01 R1/8 10 N01 NPT1/8 12 C4HC6HN7H 2.5 A B C4H 15.6 8 C6H 16.5 10 N7H 16 10.3 C4LC6LN7L C A B C D C4L 15.2 17.5 4 8.2 C6L 15.2 18.3 4 10.4
HRX-OM-W032 Contents Contents Chapter 1 Safety Instructions . 1-1 1.1 Before Using the Product . 1-1 1.2 Reading the Manual . 1-1 1.3 Hazards . 1-2 1.3.1 Level of hazards . 1-2 1.3.2 Definition of Serious injury and Minor injury . 1-2 1.4 Product Label . 1-3 1.5 Safety Measures . 1-4 1.5.1 Safety instructions for use . 1-4 1.5.2 Personal protective equipment . 1-4 1.6 Emergency Measures.
HRX-OM-S004 Contents Contents Chapter 1 Safety Instructions . 1-1 1.1 Before using the product . 1-1 1.2 Reading the Manual . 1-1 1.3 Hazards . 1-2 1.3.1 Level of hazards . 1-2 1.3.2 Definition of Serious injury and Minor injury . 1-2 1.4 Product Label . 1-3 1.5 Safety Measures . 1-4 1.5.1 Safety Instructions for Use . 1-4 1.5.2 Personal protective equipment . 1-4 1.6 Emergency Measures.
Note 1) 01 1 station Note 2) The number of max. stations differs from kit to kit. (Refer to the table below.)
D B M L Z I 1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com G 0.2 (G) H A E F (Through) N ( I ) (L) (Z) (G) C NN A B ZZ C D E M F G H I J K L N NN Q R U 2-M5 x 0.8 thread depth 4 2-M5 x 0.8 thread depth 4 2-M5 x 0.8 thread depth 4 2-Rc 1/8 thread depth 5 SS T Bore
-[-c"*'f ] sf;1 i qo3j, {Botlom pofted 1/8 NPTF oniy. (Se pg. 16 for individual subplate part nos.) * Special Order XS With surge voltage suppressor x Speciallor grommet type G only. lZ oplion N/A lor grommettype G. a Electrical entrv Volta9e 5]24voc 6 12VDC x9 Otherc Note 1) Indicate in parentheses at end of part no. Ex. (AC24V).
-[-c"*'f ] sf;1 i qo3j, {Botlom pofted 1/8 NPTF oniy. (Se pg. 16 for individual subplate part nos.) * Special Order XS With surge voltage suppressor x Speciallor grommet type G only. lZ oplion N/A lor grommettype G. a Electrical entrv Volta9e 5]24voc 6 12VDC x9 Otherc Note 1) Indicate in parentheses at end of part no. Ex. (AC24V).
8 6 6 5 N I ZZ Z NN NA Stroke range 40 32 25 20 26.5 22 20 20 51 42.5 34.5 30 45 181 159 146 146 7 200 to 1000 150 to 1000 150 to 700 150 to 700 M14 x 1.5 M10 x 1.25 M10 x 1.25 M8 x 1.25 M32 x 2 M26 x 1.5 M26 x 1.5 M20 x 1.5 1/4 1/8 1/8 1/8 46.5 37.5 33.5 8 8 8 5.5 5.5 5 41 41 56.2 10 1011Head flange (G): RECG 2 x P (Rc, NPT, G) NN H2 Width across flats B2 4 x 7 H1 G Relief port M5 x 0.8