Main Body Shape: Block Horizontal Type, Number of Ports: 4-Port, Number of Switching Positions: 3-Position Exhaust Center, Operation Status Retention: Retention, Switching Operation: Manual Lever, Effective Sectional Area(mm2): 23.98, Effective Sectional Area Class(mm2): Up to 30, Pipe Port Type: NPT, Plumbing Thread Nominal: 3/8, Mounting Method: Bottom, Plumbing Type

Bore size (mm) Part No. l Dd9 L m d H B C D Applicable cotter pin 3 X 18 l 4 X 25 l 4 X 35 l 4 X 40 l 0.040 0.076 0.050 0.093 0.065 0.117 0.065 0.117 NT-03 NT-04 NT-05 NT-08 NT-10 NT-12M CD-M03 CD-M05 CD-M08 IY-12 32 40 50, 63 80 100 125 32, 40 50, 63 80, 100 125 10 14 22 25 36 51 72 44 60 82 4 4.5 5 5 3 4 4 4 M10 X 1.25 M14 X 1.5 M18 X 1.5 M22 X 1.5 M26 X 1.5 M27 X 2.0 6 8 11 13 16 16 17

L ~ ::;; '" O.06I---+--+---+---:>I"--+-::-::c:-::!-l ~ / /o~la ~ / /v 0.7MPa ~ /-Y ~0.04 V ~ 0.04 f-i-,I"''---c,..-f'''---c-l---l-l ~ /~/ VI Q) a. 0.3MPa_0.5MPs_ ~ 80021-W'--+---+---+0.3MP.~-1__1 ~ Max.fIowline ---o.7MPa 8 0.02 Max.fIow line ~~_-0.5M!,a -I _:---..

MPa How to read the graph When a water flow of 2 l/min is generated, lP 0.017 MPa for a valve with 3 orifice (VX212, 222, 232).

R S AMR 4 0 00 02 E 3 Auto drain Additional symbol Port size 1 None With auto drain 0 Flow direction: left to right MR unit Flow direction: right to left 02 03 04 06 10 1/4 3/8 1/2 3/4 1 Applicable model AMR3l00-02 to 03 AMR4l00-02 to 04 AMR5l00-04 to 06 AMR6l00-10 R 3 4 5 6 Body size 3 4 5 6 Adapter ass'y port size (2 pcs.)

ASS AS121FG AS131FG AS221FG-01 AS231FG-01 AS221FG-02 AS231FG-02 ASR ASQ Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 07, 08, 09, 10, 11 05, 06, 07, 08, 09, 10 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 01, 03, 04 05, 06 03, 04 Number of needle rotations Number of needle rotations Number of needle rotations AS321FG AS331FG AS421FG AS431FG

Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 https://www.smcworld.com 2022 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. D-G

For Water 30 20 VX2 60-02 10 VX234.5 VX2 46 VX2 6010 VX2 50 8 3 2 04 03 3 2 3 2 VX223 10 3 2 VX2112 5 4 3 Flow rate Q l/min 2 1 0.001 (0.0018) (0.0054) 0.01 (0.017) 0.05 (0.07) 0.1 Pressure differential P = (P1 P2) MPa How to read the graph When a water flow of 2 l/min is generated, lP 0.017 MPa for a valve with 3 orifice (VX212, 222, 232).

S 100 L Flow control valve (With pressure compensation) Enables constant movement even if there are load fluctuations.

is required 45 40.6 1.8 Acceptable (OK) * Supply pressure: 0.5 MPa, Load factor: 50% 50: 2.2 L (ANR) 45: 1.8 L (ANR) = 0.4 L (ANR) 18% reduction Air consumption Compact and lightweight (32, 40, 50, 63, 80, 100) L1 L2 JMB W2 W1 Current product (Compared with the current product (MB)) W: Width L: Overall length Weight Bore size [mm] Current product W1 [mm] JMB W2 [mm] Current product L1 [

Clean Regulator/Fluororesin Type SRF Series RoHS ARJ AR425 to 935 ARX Wetted part materials Wetted part materials Wetted part materials Body: New PFA Body: New PFA AMR Body: New PFA ARM Diaphragm: PTFE Diaphragm: PTFE Diaphragm: PTFE ARP IR-A IR Recommended maximum flow rate IRV 2 L/min 5 L/min 20 L/min VEX SRF10 SRF30 SRF50 SRH SRP SRF SRF Inlet pressure: 0.3 MPa, Fluid: Water ITV Washing

AFF2B AFF22B AFF75A 1 8B 2 3 4B B Max. flow line 0.1 MPa 0.1 MPa 0.3 MPa Pressure drop (MPa) Pressure drop (MPa) Pressure drop (MPa) Max. flow line Max. flow line Air flow rate (m3/min (ANR)) Air flow rate (l /min (ANR)) Air flow rate (l /min (ANR)) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258

L O L G H F K J E D I A B C 2-4.5 A B C D E F G H I J K L Model 4 ZFC100-04 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 1/4" ZFC101-07 6 ZFC200-06 8 ZFC200-08 67 15.5 34 17.5 14 22 15.6 23.1 27 24 35 1/4" ZFC201-07 5/16" ZFC201-09 Element Replacement Element replacement procedure 1) Stop operation and reduce the filter's internal pressure to atmosphere. 2) Turn cover

L O L G H F K J E D I A B C 2-4.5 A B C D E F G H I J K L Model 4 ZFC100-04 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 1/4" ZFC101-07 6 ZFC200-06 8 ZFC200-08 67 15.5 34 17.5 14 22 15.6 23.1 27 24 35 1/4" ZFC201-07 5/16" ZFC201-09 Element Replacement Element replacement procedure 1) Stop operation and reduce the filter's internal pressure to atmosphere. 2) Turn cover

bracket) are included with the above parts. 3 Direct Operated 2 Port for Heated Water Series VCB Dimensions Grommet: G Conduit: C Q Approx. 300 F D Approx. 280 D Q F C G1/2 C R R E E B A H 2-P Port size 2-P A 2-M Thread depth N B H Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G1/2 E B A H D 2-P Port size (S) 2-M Thread depth N L K (mm) Electrical entry P Port

RUSSIA SMC Pneumatik LLC. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659 JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2003 SMC CORPORATION All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing April, 2003 D-DN P-120 (DN) Printed in Japan.

W Recommended Pneumatic Equipment CC Brake valve VFS21O VFS21O VFS21O VFS31O VFS31O Bore size (mm) Directional control valve VFS24OR VFS24OR VFS34OR VFS44OR VFS44OR Silencer AN200-02 AN200-02 AN300-03 AN300-03 AN400-04 Speed controller AS4000-02 AS4000-02 AS4000-03 AS420-03 AS420-04 Regulator AR425 AR425 AR425 AR425 AR425 Piping Nylon 8/6 or larger Nylon 10/7.5 or larger Nylon 12/9 or larger

With One-touch fitting Needle Valve/Flow Characteristics ASP330F ASP430F 400 200 3 6 Flow rate (l/min (ANR)) Inlet pressure : 0.5 MPa Inlet pressure : 0.5 MPa Inlet pressure : 0.5 MPa Inlet pressure : 0.5 MPa Flow rate (l/min (ANR)) Effective area (mm2) Effective area (mm2) 300 06 07,08,09 2 4 200 100 1 2 100 0 0 0 5 10 0 5 10 Number of needle rotations Number of needle rotations ASP530F

min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Pressure Characteristics Conditions: Upstream pressure 0.7MPa Downstream pressure 0.2MPa Flow rate Q = 20l/min (ANR) 0.30 Downstream pressure MPa 0.25 Starting point 0.20 0.15 0.10 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Upstream pressure MPa Construction ARJ310-01 ARJF310F-01 y e !

Inch size 1/4" 1/8" 5/32" Flow rate (l/min(ANR)) 170 100 120 150 IN OUT Effective area (mm2) 2.6 1.5 1.8 2.3 IN P1 Note) Flow rate is the value measured under a pressure of 0.5 MPa and a temperature of 20C.