43 36 40 36 39 93.5 83.5 39 46 39.5 48.5 44 51.5 80 45 52 45 48.5 45 47.5 103 92.5 46.5 52.5 46.5 55 51.5 58 100 53.5 60 53.5 56.5 53.5 55.5 113.5 103 55 59.5 55 62 60.5 65.5 Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.
Scale: 15% 10 6 Work piece mounting reference plane LJ1 LJ1 LG1 LC1 LX LC6D/LC6C Switches 80 5H10 depth 8 8-M5 x 0.8 thread depth 8 45 20 Cable entry side Body mounting reference plane 5H10 depth 6 Z section detail 100 201 60 50 Z section 43 Stroke + 125 (table movement range) 192 3.3 30 90 A section 83 5.8 1.7 4.8 80 Stroke + 360 A section detail (Switch groove) 11.5 40 (T-slot pitch) 36
36 0 3.5 3.5 3 AC40C-06 Note 1) For AC20C only, the position of the pressure gauge is above the piping center.
36 0 3.5 3.5 3 AC40C-06 Note 1) For AC20 only, the position of the pressure gauge is above the center of the piping.
17 81 93 106 131 156 25 37.5 50 75 100 185 12.5 125 32 36 17 72 85 97 110 135 160 25 37.5 50 75 100 12.5 185 125 17 72 32 36 85 97 110 135 160 25 37.5 50 75 100 190 12.5 125 41 46 19 77 90 102 115 140 165 25 37.5 50 75 100 Long stroke type includes ones for strokes more than 301 mm. 10-15-21 22 Series CVM5 Axial Foot Style (L) Bore size Stroke CVM5L Manual override Width across flats B1
72 12.5 85 97 110 135 25 37.5 50 75 17 32 36 72 12.5 85 97 110 135 25 37.5 50 75 17 32 36 77 12.5 90 102 115 140 25 37.5 50 75 19 41 46 10-15-30 31 Valve Mounted Cylinder Single Acting, Single Rod, Spring Return/Extend Series CVM3 20, 25, 32, 40 How to Order RE A B Bore size Solenoid valve voltage 20 25 32 40 REC 20 mm 25 mm 32 mm 40 mm Standard Option 1 2 5 Mounting style 3 4 6 9 100
HR 30 36 41 51 62 HS 8.5 7.5 6.5 7 8 K 14 11 15 13 15 B 8 9.5 9.5 11 11 HT 17 24 23.5 29 36 J x E M5 x 0.8 x 7 M6 x 1 x 8 M6 x 1 x 8 M8 x 1.25 x 10 M8 x 1.25 x 10 C 4.2 5.2 5.2 6.5 6.5 HB 17 21 23.5 29 36 CB 2 3 3 3 5 CR 0.5 1 1 1.5 2 D 16.6 21.6 26.4 33.6 41.6 F 8 9 8.5 10.5 13 G 5 6 6 7 7 GP 33 39 44 55 65 GW 31.5 37.5 42.5 53.5 63.5 H 32 39 44 55 67 HA 30 36 41 52 62 Model CY3R15 CY3R20
AL30/AL40 w Semi-standard/Bowl Assembly Part No. t e Model Semi-standard specifications With switch Bowl material With drain guide With barb fitting With bowl guard IN OUT AL20 AL10 AL60 AL50 AL40-06 AL40 AL30 Lowest limit ON Lowest limit OFF y r u C4SL-3 C1SL-3 C2SL-3 C3SL-3 C2SL-C Polycarbonate C2SL-3C C4SL-3W C4SL-6 C4SL-36 C3SL-3W C1SL-6 C2SL-6 C3SL-6 C1SL-36 C2SL-36 C3SL-36 Nylon
36 30 4 1 8 3 2 1 8 3 VHS4000 , , Note) Use air filter on IN side to protect operation .
(Spring return) VP500/700 X536 X538 X555 VG342 X87 Operation Internal pilot External pilot Operating pressure range 36 to 102 psi [0.25 to 0.7 MPa] 36 to 102 psi [0.25 to 0.7 MPa] External pilot pressure 36 to 102 psi [0.25 to 0.7 MPa] (Same as operating pressure) Maximum operating frequency 30 times/minute Minimum operating frequency 1 time/week Operating and ambient temperature 14 to 122
36 45 50 50 75 75 126 167 167 220 235 50 71 71 88 88 0 3.5 3.5 3 AC40C-06 Note 1) For AC20 only, the position of the pressure gauge is above the center of the piping.
36 N 4 4 4 6 6 8 10 G 18 18 20 9 23 12 H 32 32 40 39 36 36 NN 2 2 2 3 3 4 5 GA 18 18 20 38 48 59 84 HA 32 32 40 39 39 72 72 I 12 12 14 15 13 17 17 J 34 34 42 58 70 110 135 K 26.5 36.5 46.5 56.5 66.5 91.5 116.5 KA 117.5 142.5 NA 4 4 4 4 4 8 8 M 67 67 77 94 104 148 173 Z 66 66 76 93 103 147 172 ZZ 95 95 105 122 132 176 201 13-/22-MXQ1210 13-/22-MXQ1220 13-/22-MXQ1230 13-/22-MXQ1240 13-/22
18 36 M12 x 1 M12 x 1 M12 x 1 Vertical 36 Width across flat 14 Vertical Width across flat 14 Width across flat 14 With Buffer: Vacuum Inlet With Buffer: Vacuum Inlet 10 5 15 10 5 15 10 5 15 Lateral Lateral 2 2 2 With Adapter: Vacuum Inlet 17 16 11.4 1.8 13 8.4 1.8 11 10 6 1.8 With Adapter: Vacuum Inlet 14 Lateral With Buffer: Vacuum Inlet Construction Adapter Applicable Pad List ZP3-T10B
(mm) Stroke range Bore size (mm) I J K M B D C E KA GA GB H 51 57 66 78 92 110 144 M5 x 0.8 M5 x 0.8 M6 x 1 M6 x 1 M8 x 1.25 M8 x 1.25 M12 x 1.75 8 8 10 10 14 14 20 11 12 22 25 25 25 25 25 30 36 45 55 68 87 11 12 16 21 26 32 36 21 24 30 36 46 53 65 16 26 28.5 34.5 40 46.5 54 20 21 35 40 45 50 50 29 33 38 46 55 66 86 39 43 49 59 71 82 106 20 25 32 40 50 63 80 12.5 18 19.5 23.5 28 34.5 36 Up
bytes Input 36 bytes Output 36 bytes Input 36 bytes Output 36 bytes Input 4, 10, 20 bytes Output 4, 12, 20, 36 bytes Input 14 bytes Output 22 bytes Terminating resistor Not included Memory EEPROM LED indicator PWR, RUN, ALM, ERR PWR, ALM, MS, NS PWR, ALM, SF, BF PWR, ALM, MS, NS PWR, ALM, COM Cable length [m] Actuator cable: 20 or less Cooling system Natural air cooling Operating temperature
Speed 600 mm/s REAR20 3 1 9 9.5 5.2 22.8 9 6 39 37.5 39 36 38 36 7.5 21 M6 x 1 x 8 REAR25 3 1 8.5 9.5 5.2 27.8 8.5 6 44 42.5 44 41 43 41 6.5 23.5 M6 x 1 x 8 REAR32 3 1.5 10.5 11 6.5 35 10.5 7 55 53.5 55 52 54 51 7 29 M8 x 1.25 x 10 Direct Mount Type REBR REAR40 5 2 10 11 6.5 43 13 7 65 63.5 67 62 66 62 8 36 M8 x 1.25 x 10 LD MM N P PW Q WS Z QW T W X Y K L M Model REAR10 3.5 M3 x 0.5 4.5
44 36 36 C76 80 46.5 46.5 55 52.5 47.5 103 58 52 92.5 48.5 45 51.5 45 45 100 55 55 62 59.5 55.5 113.5 65.5 60 103 56.5 53.5 60.5 53.5 53.5 C85 125 66.5 66.5 71.5 70.5 67.5 125 76.5 72 115 68.5 65 72 65 65 C95 Operating Range CP95 (mm) Auto switch type Bore size 32 40 50 63 80 100 125 NCM D-Z7/Z80 13 10 17 7.5 8.5 7.5 9.5 9.5 10.5 9 9 10 11 11 11 NCA D-A5/A6 D-A59W D-A3/A44 13 13
L-bracket 2.3 30 36 52 40 22 Straight type 3 m Cable connector TM-4DSX3HG4 50 Right angle type 3 m 4 x 5.5 8 x 4.5 4 x 7 22 TM-4DLX3HG4 50 36 40 84 40 36 22 40 5 36 7 4 x 5.5 8 x 4.5 22 14 20 60 70 12 1.6 14-8-15 16 Series ITV1000/2000/3000 Working Principle When the input signal rises, the air supply solenoid valve q turns ON, and the exhaust solenoid valve w turns OFF.
S) (mm) Dimensions (mm) Dimensions W W S Model LVA2 LVA3 LVA4 LVA5 LVA6 Model LVA20 LVA30 LVA40 LVA50 LVA60 11.5 70.5 24 92.5 A B A B 29 110.5 SMC SMC 34.5 147 36 156 Dimensions (mm) A B C E D G H J K L M N R U P Q Model Rc 1/4 NPT 1/4 LVA2 30 36 61 44 14.5 35 13 4 20 37 3.5 30 M5 x 0.8 M3 x 0.5 Rc 3/8 NPT 3/8 LVA3 36 47 81.5 56 19 45.5 17.5 7.5 34 46 5.5 41.5 Rc 1/2 NPT 1/2 LVA4 46 60
Refer to p.0-33 to 0-36 for Safety Instructions and common precautions. Precautions Operation of Manual Override Warning Plug position Configuration B port N.C. A port N.O. (A) 4 (B) 2 (A) 4 (B) 2 Plug Plug Single Double Use caution since manual override operation will operate any connected actuators.