Model: 7 (VP700), Body: 44 (Base Mounted), Pilot: R (External Pilot), Valve Electrical Entry: D (DIN Terminal w/Connector, w/Pitch 9.4mm Standard), Port: 04 (1/2, VP700), Thread: Rc, Bracket: M, Switch Electrical Entry: M (M12 Connector, OMRON), Check Valve, External Pilot Only: A (Applicable Tube O.D. ø6)
Model: 7 (VP700), Body: 44 (Base Mounted), Pilot: R (External Pilot), Valve Electrical Entry: D (DIN Terminal w/Connector, w/Pitch 9.4mm Standard), Port: 04 (1/2, VP700), Thread: Rc, Bracket: None, Switch Electrical Entry: M (M12 Connector, OMRON), Check Valve, External Pilot Only: A (Applicable Tube O.D. ø6)
Model: 7 (VP700), Body: 44 (Base Mounted), Pilot: R (External Pilot), Valve Electrical Entry: D (DIN Terminal w/Connector, w/Pitch 9.4mm Standard), Port: 04 (1/2, VP700), Thread: N (NPT), Bracket: M, Switch Electrical Entry: M (M12 Connector, OMRON), Check Valve, External Pilot Only: B (Applicable Tube O.D. ø1/4")
Model: 7 (VP700), Body: 44 (Base Mounted), Pilot: R (External Pilot), Valve Electrical Entry: D (DIN Terminal w/Connector, w/Pitch 9.4mm Standard), Port: 04 (1/2, VP700), Thread: N (NPT), Bracket: M, Switch Electrical Entry: M (M12 Connector, OMRON), Check Valve, External Pilot Only: None
Model: 7 (VP700), Body: 44 (Base Mounted), Pilot: R (External Pilot), Valve Electrical Entry: D (DIN Terminal w/Connector, w/Pitch 9.4mm Standard), Port: 04 (1/2, VP700), Thread: Rc, Bracket: None, Switch Electrical Entry: M (M12 Connector, OMRON), Check Valve, External Pilot Only: None
Model: 7 (VP700), Pilot: R (External Pilot), Valve Electrical Entry: D (DIN Terminal w/Connector, w/Pitch 9.4mm Standard), Port: 03 (3/8, VP500), Thread: Rc, Switch Electrical Entry: M (M12 Connector, OMRON), Check Valve, External Pilot Only: None
Model: 7 (VP700), Pilot: R (External Pilot), Valve Electrical Entry: D (DIN Terminal w/Connector, w/Pitch 9.4mm Standard), Port: 04 (1/2, VP700), Thread: F (G), Switch Electrical Entry: M (M12 Connector, OMRON), Check Valve, External Pilot Only: None
Model: 7 (VP700), Pilot: R (External Pilot), Valve Electrical Entry: D (DIN Terminal w/Connector, w/Pitch 9.4mm Standard), Port: 04 (1/2, VP700), Thread: Rc, Switch Electrical Entry: G 1/2, OMRON, Check Valve, External Pilot Only: A (Applicable Tube O.D. ø6)
Model: 7 (VP700), Pilot: R (External Pilot), Valve Electrical Entry: D (DIN Terminal w/Connector, w/Pitch 9.4mm Standard), Port: 04 (1/2, VP700), Thread: Rc, Switch Electrical Entry: M (M12 Connector, OMRON), Check Valve, External Pilot Only: None
Model: 7 (VP700), Pilot: R (External Pilot), Valve Electrical Entry: D (DIN Terminal w/Connector, w/Pitch 9.4mm Standard), Port: 04 (1/2, VP700), Thread: Rc, Switch Electrical Entry: M (M12 Connector, OMRON), Check Valve, External Pilot Only: A (Applicable Tube O.D. ø6)
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The series may be used as either a selector valve, or a divider valve. It is vacuum applicable up to –101.2kPa. Series VP3145/3165/3185 is a large size, 3 port solenoid valve with a rubber seal. It is possible to use the series in vacuum
Model: VP700, Pilot: External Pilot, Valve Electrical Entry: DIN Terminal w/Connector, w/Pitch 9.4mm Standard, Port: 3/8, VP500, Thread: Rc, Switch Electrical Entry: M12 Connector, OMRON, Check Valve, External Pilot Only: None
Model: VP700, Pilot: External Pilot, Valve Electrical Entry: DIN Terminal w/Connector, w/Pitch 9.4mm Standard, Port: 1/2, VP700, Thread: Rc, Switch Electrical Entry: G 1/2, OMRON, Check Valve, External Pilot Only: Applicable Tube O.D. ø6
S2 S3 S0 S1 S2 S3 U0 U1 U2 U3 S0 S1 S2 S3 Without cable Without cable Without cable (2) Max. 16 stations (2) Max. 16 stations (2) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) Max. 16 stations Kit P Kit P Kit J Kit J Kit F Kit F L S The valve is equipped with an indicator light
8 9 A B C D E F 1 4.1 + *S2 S1 DC24V MADE IN JAPAN 2 3 4 (48.5) (50) 133 10.5 10.5 5.1 4.5 5 5 Models Output unit can be used for mixed connection with PCW series.
S2 S1 S2 S1 S2 S1 Master unit V BDH SD FG SD FG SD FG SD FG CANL Twisted pair wire with shield FG BDL Class 3 ground Class 3 ground Class 3 ground Class 3 ground CANH V+ Connect the shielding wire to the SD terminal.
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The series may be used as either a selector valve, or a divider valve. It is vacuum applicable up to –101.2kPa. Series VP3145/3165/3185 is a large size, 3 port solenoid valve with a rubber seal. It is possible to use the series in vacuum
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The series may be used as either a selector valve, or a divider valve. It is vacuum applicable up to –101.2kPa. Series VP3145/3165/3185 is a large size, 3 port solenoid valve with a rubber seal. It is possible to use the series in vacuum
flow rate adjusting needle (PE port) Interface plate 63.5 18 4 15.5 2-3.3 Mounting hole M5 (or M6) (V port) Vacuum pad connection port M5 (or M6) (PV port) Air supply pressure port Bracket A (Standard accessory) Note) Dimensions : For mounting bracket A : For mounting spacer 1. 13-2-26 26 Vacuum Module: Ejector System Series ZX Adsorption confirmation switch (ZSP1) ZX1-K8-P Spacer 1: ZX1-S1
flow rate adjusting needle (PE port) Interface plate 63.5 18 4 15.5 2-3.3 Mounting hole M5 (or M6) (V port) Vacuum pad connection port M5 (or M6) (PV port) Air supply pressure port Bracket A (Standard accessory) Note) Dimensions : For mounting bracket A : For mounting spacer 1. 13-2-26 26 Vacuum Module: Ejector System Series ZX Adsorption confirmation switch (ZSP1) ZX1-K8-P Spacer 1: ZX1-S1