SMC Corporation of America
Elite Part Number Search
Search Results "VX3135-00-5TZ1"

Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 3 (Common), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type

Function: 5 (3 Position Pressure Center), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type

Function: 3 (3 Position Closed Center), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type

Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Valve Type: 5-Port Valve, Actuation: Double, Status at Power Off: Self-Retaining, Valve Positions: 2-Position Normally Open, Applicable Cylinder Diameter(Ø): -, Pipe Port Type: -, Port Size: -, Pressure Rating(MPa): 0.1 to 0.7, Driving Type: Pilot Type Spool, Pilot Air Supply

Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type

Function: 3 (3 Position Closed Center), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type

Function: 2 (2 Position Double), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type

Function: 4 (3 Position Exhaust Center), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type

Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Valve Type: 5-Port Valve, Actuation: -, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 3-Position Closed Center, Applicable Cylinder Diameter(Ø): -, Pipe Port Type: -, Port Size: -, Pressure Rating(MPa): 0.15 to 0.7, Driving Type: Pilot Type Spool,

Function: 3 Position Exhaust Center, Piping: Base Mounted, Exhaust: Individual, Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 24VDC, Lead Wire: Conduit Terminal, Light/Surge Suppressor: With light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: -, Thread: -, Bracket: -, Made to Order: -

Function: 2 Position Single, Piping: Base Mounted, Exhaust: Common, Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 24VDC, Lead Wire: Conduit Terminal, Light/Surge Suppressor: With light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: -, Thread: -, Bracket: -, Made to Order: -

Function: 3 Position Pressure Center, Piping: Base Mounted, Exhaust: Individual, Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 24VDC, Lead Wire: Conduit Terminal, Light/Surge Suppressor: With light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: -, Thread: -, Bracket: -, Made to Order: -

Function: 2 Position Single, Piping: Base Mounted, Exhaust: Individual, Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 24VDC, Lead Wire: Conduit Terminal, Light/Surge Suppressor: With light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: -, Thread: -, Bracket: -, Made to Order: -

Body Size: 60, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: EN [EtherNet/IPâ„¢, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option

A maximum effective area of 670mm² (2B) can be covered by the combination of an ultra-compact electro-pneumatic pilot valve (22.4 X 30 X 39) and a 3 port, high-capacity exhaust main regulator (VEX1*00 series).