0 execution error: Data 15 B 000B) 16 0 Alarm 3 17 0 Alarm history 3 (Origin parameter 18 0 error: 0006) 19 6 20 0 21 0 Alarm 4 Alarm history 4 (No alarm: 0) 22 0 23 0 Calculated 24 value Checksum(LRC) 25 Calculated value 26 End code CR 27 LF (iii) Irregular response Example 1 Start code 2 ID 0 3 1 Controller ID: 1 4 Function code 8 5 3 Function code & MSB + 1 = "83h" 6 Error code 0 7 1
Application Example qBlow off valve (SYJ llR) 3 5 7 wValve for vacuum control eOperation of a single acting cylinder rDivider valve (SYJ llR) tSelector valve (SYJ llR) yPressure release Valve (SYJ llR) 3 5 7 3 5 7 3 5 7 (SYJ llR) 3 5 7 3 5 7 3 5 7 (SYJ ll/SYJ ll R) X port X port X port X port X port Tank Tank 0.2MPa (R)3 2(A) (R)3 2(A) 2(A) (R)3 2(A) 2(A) 2(A) (R)3 (P)1 (R)3 (R)3 (P)1 Plug
Manifold can be mounted to VEX1B33, VEX1230 3. 14-6-2 3 Precision Regulator Series VEX130 3 Specifications VEX1B33M5 01 VEX113 01 02 0 3 VEX123 01 02 0 3 VEX133 02 03 04 0 3 VEX153 04 06 10 0 3 VEX173 10 12 0 3 VEX193 14 20 0 3 VEX1A33M5 01 Model Operation Manual (Push locking slotted type) Manual handle (Push locking slotted type) and Air operated type Internal pilot External pilot can be
Thread type Rc G NPT NPTF Nil F N T Stations 02 : 10 2 stations : 10 stations D side U side 1 2 3 4 5 How to Order Valves (VCA30/40) VC A 5 1 G 3 4 03 For air Thread type Rc G NPT NPTF Nil F N T Series 3 4 Class 3 Class 4 Port size (OUT) 5 N.C. for manifold Valve type Symbol 03 04 06 Class 3 Port size 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Fluid General air Dry air Nil A Orifice size Orifice
VHS400-02 VHS401-02 VHS400-03 VHS401-03 VHS400-04 VHS401-04 VHS500-06 VHS501-06 Pipipng direction Port size 3 4 1 2 3 8 1 4 1(P) 2(A) 21 105 76 54 35 35 57 93 Effective area (mm2) Mass (kg) 2(A) 3(R) 0.25 0.34 The front face of the handle is the reference position. Easy to Operate The direction of air flow can be verified at a glance by the orientation of the handle.
(EB) Port size 2 position double 2(B) (A)4 Symbol Applicable series Nil Port size Without sub-plate 2 1 8 (EA)5 1 (P) 3(EB) 01 SYA3000 With sub-plate 1 4 3 position closed center With sub-plate 02 SYA5000 2(B) (A)4 1 4 3 With sub-plate 02 SYA7000 (EA)5 1 (P) 3(EB) 3 8 With sub-plate 03 3 position exhaust center 2(B) (A)4 4 (EA)5 1 (P) 3(EB) 3 position pressure center 2(B) (A)4 5 (EA)5 1 (
2 position single G F Port size 1 N NPT Port size Without sub-plate Symbol Applicable series Nil NPTF T 2 position double 1 8 01 SYA3000 Port size With sub-plate 2 1 4 Port size Without sub-plate Symbol Nil With sub-plate 02 SYA5000 1 4 3 position closed center 02 With sub-plate 3 3 8 With sub-plate 03 3 position exhaust center 4 3 position pressure center 5 1728 5 Port Air Operated Valve
from the VY Valve. 02 14 2.0 3 03 38 3.3 body Ported Type 04 12 3.9 Terminal Designations are as follows: 04 12 7.2 5 06 34 8.9 1 = 24v Power Supply 2 = Control Signal 3 = Common Negative for both power and signal. 10 1 10 5% 2% + -2% 7 10 1 114 17 12 114 18 9 14 112 2 33 20 2 37 Courtesy of Steven Engineering, Inc. !
2 Symbol Nil Port size Without sub-plate Without sub-plate (Pilot port: Expect RC) 1 4 With sub-plate 02 SYA5000 3 position closed center 00 3 1 4 02 With sub-plate 3 8 With sub-plate 3 position exhaust center 03 4 3 position pressure center 5 5-2-3 2 Series SYA3000/5000/7000 Specifications Fluid Operating pressure range MPa Air 0.15 to 0.7 0.1 to 0.7 0.2 to 0.7 (0.7 x P + 0.1) to 0.7P:
3-wire (PNP) Grommet 2-wire 12V Connector 3-wire (NPN) 5V, 12V 12V IC circuit Terminal conduit 2-wire 3-wire (NPN) Relay PLC Yes 24V 5V, 12V IC circuit Diagnostic indication (2-color display) 3-wire (PNP) 12V 2-wire With timer Water resistant (2-color display) Grommet 3-wire (NPN) 5V, 12V IC circuit With diagnostic output (2-color display) 4-wire (NPN) Latch type with diagnostic output
I N L E T P O R T 10 10mm Tube 12 12mm Tube 16 16mm Tube 03 Rc3/8 04 Rc1/2 T03 3/8NPTF T04 1/2NPTF 10 10mm Tube 12 12mm Tube 02 Rc1/4 03 Rc3/8 T02 1/4NPTF T03 3/8NPTF Courtesy of Steven Engineering, Inc. !
Note 3) See How to Order below for items represented by .
-06-08-01S-3 33 80 83 84 17 20 15.5 12.8 45.4 17 11.1 18.5 76.5 77 78 41 6 KM14-06-08-02S-3 15.2 12.8 KM14-06-08-03S-3 1 4 3 8 1 2 10 6 KM14-06-10-02S-3 44 45 67 7.5 KM14-06-10-03S-3 18.5 12.8 KM14-06-10-04S-3 87.5 88.5 92 81.5 82 84 19 22 21 19 12.8 45.4 17 12.8 21 1 4 3 8 1 2 10 8 KM14-08-10-02S-3 48 88 89 90.5 94 95 98.5 19 71 7.5 KM14-08-10-03S-3 18.5 15.2 KM14-08-10-04S-3 22 22.5 19
Rated voltage 3 2 1 110 VAC 50/60 Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz Model Port size (Rc 1/4) (Rc 3/8) (Rc 1/2) (Rc 3/4) (Rc 1) 02 03 04 06 10 2232 2232 2242 2352 2362 4 5 6 7 8 9 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC for inquiry.) Refer to the table (1) given below for availability. Refer to page 17-3-65 for ordering a coil only.
Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the
Body size 3 4 5 6 1 Pressure gauge 8 3 ARX 1 2 None With pressure switch Nil S None Adapter assembly 4 3 1/4 3/8 1/2 3/4 1 AMR AMR Port size Thread type Thread type ARM Symbol Port size Nil N F Nil N G Rc NPT G Rc NPT G 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the port size of the body.
NVEP NVEF 3 1 r T 1 0 3 4 0 T I tffi IFTC I B"dt nowj I Rate rype I I Ports Port Size Code Max. Etfective Orifice (mm2) NPTF (Base mount type) 1 1 3 02=1h 03 = 3/s I .t 1 30 Q2=1/t 03=9e O4=1/z 1 45 03 =3/8 04=1/z 06=aa (Base mount type) 1 2 02=lL 03 = 3/s 8 4.5 4 ?.
NVEP NVEF 3 1 r T 1 0 3 4 0 T I tffi IFTC I B"dt nowj I Rate rype I I Ports Port Size Code Max. Etfective Orifice (mm2) NPTF (Base mount type) 1 1 3 02=1h 03 = 3/s I .t 1 30 Q2=1/t 03=9e O4=1/z 1 45 03 =3/8 04=1/z 06=aa (Base mount type) 1 2 02=lL 03 = 3/s 8 4.5 4 ?.
Cotter pin size C type, 9 for shaft C type, 9 for shaft 3 x 18l 3 x 18l Size Tolerance -0.013 -0.035 -0.013 -0.035 -0.016 -0.043 -0.016 -0.043 AD-EI-20 AD-EI-25 AD-EI-32 AD-EI-40 20 25 32 40 45.5 45.5 52 60 35.5 35.5 42 50 3.2 3.2 4 4 10 10 12 12 +0.058 0 +0.2 +0.1 Y-02 14 5 20 18 M8 x 1.25 36 16 9 3.2 x 16l 20 CDP-1 9 +0.058 0 +0.2 +0.1 Y-03 14 5 20 18 M10 x 1.25 38 18 9 25 CDP-1 9 4 x 20l