OUT2 P2(n2) P1(n1) Supply pressure verification Leak test CH P2(n1) > P1(n2) 10.0 to 101.0 kPa Increases the set value 1 2 3 4 PRESSURE For normally closed P2(n2) P1(n1) P2(n1) > P1(n2) 0.1 to 1000.0 MPa Decreases the set value SET P3(n3) and P4(n4) are the same as P1(n1) and P2(n2).
Supply pressure verification Leak test P2(n1) > P1(n2) P2(n2) P1(n1) 10.0 to 101.0kPa CH Increases the set value 1 2 3 4 PRESSURE For normally closed P2(n1) > P1(n2) P2(n2) P1(n1) 0.1 to 1000.0MPa Decreases the set value SET P3(n3) and P4(n4) are the same as P1(n1) and P2(n2).
Set value input mode Press the "SET" button to display "P1-20" 1. The output OUT1(1) set value input mode is selected. 1: The set value of P1 is -20 ZSE3/ISE3(L) kPa RESET SET LED Bottom hold mode Pressing the button when pressure is displayed enables the lower limit peak value (value with low vacuum) to be held. In this case "d" is displayed on the LCD.
SGH Ex. 2) 3 port valve: Switching nozzle 12 VNC VNH Port 12(P1) (Pilot air SUP port) Nozzle Port 12(P1) (Pilot air SUP port) 3 1 2 VNH VNH Tank Coolant pump VND Switching nozzles on supplying coolant liquid.
Type (mm) 1in = 25.4mm PA3000 115 68 85 105 4-7 7.5 FLUID OUT 3/8 5.5 AIR SUP (P1) 1/4 FLUID OUT PROCESS PUMP P1 2 90 74.5 FLUID I N P2 44.5 3 AIR SUP (P2) 32 1/4 100 130 FLUID IN 3/8 PA5000 179 4-9 90 90 FLUID OUT 1/2, 3/4 AIR SUP (P1) 1/4 112 56 165 56 RESET PROCESS PUMP FLUID OUT 167 P1 132.5 FLUID I N 125.5 103.5 P2 58.5 48.5 202 114 3.5 3 AIR SUP (P2) FLUID IN 1/2, 3/4 1/4 10 Series
Type PA3000 115 68 85 105 4-7 7.5 FLUID OUT Rc 3/8 5.5 AIR SUP (P1) Rc 1/4 FLUID OUT PROCESS PUMP P1 2 90 74.5 FLUID I N P2 44.5 3 AIR SUP (P2) 32 Rc 1/4 100 130 FLUID IN Rc 3/8 PA5000 179 4-9 90 90 FLUID OUT Rc 1/2, 3/4 AIR SUP (P1) Rc 1/4 112 56 165 56 RESET PROCESS PUMP FLUID OUT 167 P1 132.5 FLUID I N 125.5 103.5 P2 58.5 48.5 202 114 3.5 3 AIR SUP (P2) FLUID IN Rc 1/2, 3/4 Rc 1/4 10
Type PA3000 115 68 85 105 4-7 7.5 FLUID OUT Rc 3/8 5.5 AIR SUP (P1) Rc 1/4 FLUID OUT PROCESS PUMP P1 2 90 74.5 FLUID I N P2 44.5 3 AIR SUP (P2) 32 Rc 1/4 100 130 FLUID IN Rc 3/8 PA5000 179 4-9 90 90 FLUID OUT Rc 1/2, 3/4 AIR SUP (P1) Rc 1/4 112 56 165 56 RESET PROCESS PUMP FLUID OUT 167 P1 132.5 FLUID I N 125.5 103.5 P2 58.5 48.5 202 114 3.5 3 AIR SUP (P2) FLUID IN Rc 1/2, 3/4 Rc 1/4 10
Type) Dimensions: Air Operated Type PA3000 115 68 85 VC VDW 105 4-7 7.5 VQ FLUID OUT Rc 3/8 5.5 VX2 AIR SUP(P1) Rc 1/4 VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com FLUID OUT PROCESS PUMP VX3 P1 2 VXA 90 74.5 FLUID I N VN P2 44.5 3 32 Rc 1/4 AIR SUP(P2) LVC
) 12 (P1) 10 (P2) PB Power consumption DC Holding Inrush Apparent power AC Air operated 2 (B) 1 (A) 2 (B) 1 (A) 2 (B) 1 (A) 10 (P2) Manual override VNA11 VNA12 12 (P1) 12 (P1) External pilot solenoid 1 (A) 2 (B) 2 (B) 1 (A) 17-4-7 4 Series VNA Port size 6A, 8A, 10A Applicable cable O.D. 6 to 8 (D.T) 125 (Conduit terminal: T DIN terminal: D) 108.2 (Grommet terminal: E) 106.7 (Grommet: G) 63
)) Relief flow rate (L/min (ANR)) IR1010-01 IR1010-01 IR1010-01 Back pressure: 0.7 MPa Supply pressure: 0.7 MPa 0.4 0.204 0.7 Set pressure P2 (MPa) Set pressure P2 (MPa) Set pressure (MPa) 0.6 0.202 0.3 0.5 Set point 0.4 0.200 0.2 0.3 0.198 0.2 0.1 0.1 0.196 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 1.0 0 40 80 120 160 200 0 50 100 150 200 250 300 350 Flow rate (L/min (ANR)) Supply pressure P1
IR1000-01 IR1000-01 IR1000-01 Conditions: Back pressure 0.5MPa Conditions: Supply pressure 0.5MPa 0.5 0.204 0.2 Set pressure P2 MPa Set pressure MPa Set pressure MPa 0.4 0.202 0.15 Setting point 0.3 0.200 0.1 0.2 0.198 0.05 0.1 0.196 0 0.2 0.1 0.4 0.3 0.6 0.5 0.8 0.7 0.9 1.0 0 40 20 80 60 100 140 120 0 50 100 200 250 150 Flow rate l/min (ANR) Relief flow rate l/min (ANR) Supply pressure P1
ISE When the values of P1 and P2 are the same or when P1>P2 within three digits, the hysteresis will be automatically three digits for the set value of P1. Window comparator mode: ZSE The hysteresis is two digits, so separate P1 from P2 by five digits or more and set them.
(A conversion cable is not required for the JXC-W2.) 2 Step Motor Controller JXCE1/91/P1/D1/L1 Series How to Order Actuator + Controller R1 CD17T LEFS16B-100 Controller Nil Without controller Cm1mm With controller Actuator type Refer to How to Order in the actuator catalog. For compatible actuators, refer to the table below.
For saturated steam Viewing the graph [664] (183) Upstream pressure of valve P1 = 1.0MPa 1.0 The sonic range pressure to generate a flow rate of 25kg/h for orifice 3 (VCS21) is P1 approx. 0.68MPa for orifice 4 (VCS21) is P1 approx. 0.40MPa for orifice 5 (VCS21) is P1 approx. 0.29MPa The holding heat differs somewhat depending on the pressure P1, but at 25kg/h it is approximately 16000kcal
For saturated steam Viewing the graph [664] (183) Upstream pressure of valve P1 = 1.0MPa 1.0 The sonic range pressure to generate a flow rate of 25kg/h for orifice 3 (VCS21) is P1 approx. 0.68MPa for orifice 4 (VCS21) is P1 approx. 0.40MPa for orifice 5 (VCS21) is P1 approx. 0.29MPa The holding heat differs somewhat depending on the pressure P1, but at 25kg/h it is approximately 16000kcal
) 12(P1) 12(P1) 12(P1) 10(P2) 10(P2) 10(P2) 10(P2) 12(P1)10(P2) 2 4 4 VNB0 VNB02 VNB03 VNB1 12 () (P1) (P2) () 10 ()12(P1) 10(P2) 2 VNB01V VNB02V VNB1 V 12 (P1) 10 (P2) VNB 1V (N.C.) 0 6 VN*-OMJ0001-B () P2 O O 7 VN*-OMJ0001-B No. 1 2 3 4 5 6 7 8 9 10 11 P2N.C.
. -4VEX-OMO0001 3 0 VEX1 3 Series / / / / / / / / ( ( ( ( ) ) ) ) -5VEX-OMO0001 3 VEX1 3 Series 0 ON-OFF (AF ) (AMAFM ) (P.2.3) [1 P][1P] PE ( ( ( ( ) ) ) ) IR2000 VEX 33 ITV VY 11 (0.5MPa ) (0.1MPa ), 2 Nm 1/6 MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa MPa -6VEX-OMO0001 3 VEX1 3 Series 0 +0.1MPa 2 PE(ASN2-M5) 0.1MPa P1 O M5 P1 O VEX1-A30-3 O P1 P1 P1
Nil FKM 1349-80*1 N1 EPDM 2101-80*1 P1 Barrel Perfluoro 70W Q1 Kalrez 4079 R1 Chemraz SS592 R2 SS630 R3 SSE38 S1 VMQ 1232-70*1 T1 FKM for Plasma 3310-75*1 *1 Values at normal temperature, excluding gas permeation *2 Refer to Construction on page 5 for changed part. Number corresponds with the parts number on the construction drawing.
) (P1) (P1) (P1) 10(P2) 10(P2) 10(P2) 10(P2) 12(P1)10(P2) 15A 211 420-04 1/2 B(12.7) 20A 311 500-06 3/4 B(19.1) 25A 411 600-10 1 B(25.4) 2 32A 511 800-12 1 1/4 B(31.8) VNA01 VNA02 VNA03 VNA1 40A 611 900-14 1 1/2 B(38.1) (P1) () 12 50A 711 900-20 2 B(50.8) (P2) () 10 (),12(P1) 10(P2) EXH , 6 VN-OMP0002 1 2 3 () 4 P2 5 6 7 8 9 10 11 O O 12 13 14 7 VN-OMP0002 No. 1 2 3 4