(Default setting) 8 7 Configuration Mode Address X1 9 6 x10 x1 2 1 0 0 5 Mark C on the unit Mark B at cable end Mark A at cable end 4 Address 1 9 4 3 1 0 : : (1) 2 3 Input data + System diagnosis + Unit diagnosis (Up to 10 units) Input data + System diagnosis Input data only (Default setting) 8 7 9 6 6 Content 3 4 1 2 0 5 Content 5 0 (Default setting) 4 1 2 3 Node Address Data Rate 8 7 PGM
7 8 9 10 11 (BUS IN) 12 (2 ) (BUS OUTPCI) -16No.EX-OMN0027CN-D BUS IN BUS OUT 1 NC 2 RXD/TXD-N 3 NC 4 RXD/TXD-P 5 Shield T PROFIBUS DP BUS OUT SI IP67 PROFIBUS DP A [kbps] 9.6 19.2 45.45 93.75 187.5 500 1,500 3,000 6,000 12,000 [m] 1,200 1,000 400 200 100 -17No.EX-OMN0027CN-D (1) (2) (3) (4) (0.30.4Nm) OFF OFF 0, -18No.EX-OMN0027CN-D PROFIBUS DP (X10)PROFIBUS DP (X1
Red LERR LED is flashing 1 3 4 1 2 Content Err (Default setting) 5 2.5 Mbps 625 kbps Content 5 Mbps CC-Link version Node number 2.00 2.00 2.00 2.00 1.10 1.10 1.10 1.10 64 1 : 8 7 9 6 Number of occupied nodes x10 x1 0 5 4 4 Pin number 1 Address 2 3 5 3 1 4 2 3 2 1 1 4 3 2 1 (2) (3) Content 8 7 9 6 6 Number of occupied nodes SI unit output data size 4 byte (Default setting) 0 5 4 1 2 3 Signal
Extended cyclic occupied units RX/RY stations 1 15 1.10 x1 2 64/64 8/8 2 15 1.10 x1 4 128/128 16/16 3 15 2.00 x8 2 384/384 64/64 4 15 2.00 x8 4 896/896 128/128 5 31 2.00 x8 2 384/384 64/64 6 31 2.00 x8 4 896/896 128/128 7 63 2.00 x8 4 896/896 128/128 8 127 2.00 x8 4 896/896 128/128 * The last register of the bit area (16 bits) cannot be used as it is allocated for the system area.
UTC SPECIAL DESIGN. 1"x1"x1" NPT PVC Tee Fitting. 0.22600 lb. H41.
X1 0.2 MPa, 0.4 MPa and 0.8 MPa settings can be combined. Set pressure Accessory (Pressure gauge) G33--01 (IR1000), G43--01 (IR2000) Non-grease specifications Note 1) Regulators to be manifolded are counted starting from stations 1 on the left side with the OUT ports in front.
Type of seal Special Options R Rubber S Metal Standard X1 External Pilot Supply Size 6 Size 1 8 Size 2 10 Size 3 Pilot Exhaust Options Pilot Exh. through footprint V1 External Individual Pilot Exhaust Configuration FG 2-position Number of Solenoid Subplate (NPTF) FHG 3-position, Closed center FJG 3-position, Exhaust center Without Subplate A02T Side 1/4 For VSR/S8-6 S Single D Double FIG
ll9#x1'&l?3flrin c8-se of (6so)sr=13.6ks 1s) a=1366=6.6s catculation formuta tor cr (o<1) 3ff9i,3?
Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTING, CONNECTORS, KA FITTING FOR ANTI STATIC, FX, KA 6MM, .01895 lb
Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTING, CONNECTORS, KA FITTING FOR ANTI STATIC, JD, KA 10MM, .03176 lb
Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTINGS, CONNECTORS, KA FITTING FOR ANTI STATIC, CJ, KA 4MM, .02204 lb
Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTINGS, CONNECTORS, KA FITTING FOR ANTI STATIC, FJ, KA 6MM, .02089 lb
Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTING, UNION ELBOW, CONNECTORS, KA FITTING FOR ANTI STATIC, AX, KA 3.2MM, .01100 lb
Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTING, UNION ELBOW, CONNECTORS, KA FITTING FOR ANTI STATIC, AJ, KA 3.2MM, .01470 lb
Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTINGS, CONNECTORS, KA FITTING FOR ANTI STATIC, AJ, KA 3.2MM, .01760 lb
Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTINGS, CONNECTORS, KA FITTING FOR ANTI STATIC, FH, KA 6MM, .02204 lb
Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTINGS, CONNECTORS, KA FITTING FOR ANTI STATIC, FH, KA 6MM, .05566 lb
Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTING, CONNECTORS, KA FITTING FOR ANTI STATIC, HH, KA 8MM, .06982 lb
Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITTING, CONNECTORS, KA FITTING FOR ANTI STATIC, JH, KA 10MM, .08818 lb
Antistatic One-touch fittings series KA has one-touch loading and unloading. Series KA can be used in copper- free applications and in vacuum (max. -100kPa). Conductive resin is used for body and seals in fittings and tubing. Series KA is flame resistant (UL94 standard, V-0)., FITITNG, CONNECTORS, KA FITTING FOR ANTI STATIC, JH, KA 10MM, .11220 lb