SMC Corporation of America
Elite Part Number Search
Search Results "CS2B160-150"

Its maximum operating temperature is 150 C. KQB2 fittings can be used with fluid, and in environments having a large temperature change. Configuration variations have been improved to 17 models. Applicable tube sizes are +3.2 to +16 and 1/8" to 1/2".

Material: S (Stainless Steel 304), Number of Arranged Elements: 29, Element Length: B [ℓ500 (ℓ250 x 2)], Port Size: 60 [150 (6B)], Element Type: M (Micromesh, Stainless Steel 304/Epoxy Material), Nominal Filtration Accuracy: 20 μm, Element Seal Material: V (FKM)

Material: S (Stainless Steel 304), Number of Arranged Elements: 29, Element Length: C [ℓ750 (ℓ250 x 3)], Port Size: 60 [150 (6B)], Element Type: M (Micromesh, Stainless Steel 304/Epoxy Material), Nominal Filtration Accuracy: 20 μm, Element Seal Material: V (FKM)

Style: L3 (Copper Pipe Long L300mm), Connection Size: 06 (One-touch Fitting Ø6), Nozzle Diameter: 150 (Ø1.5)

Style: L6 (Copper Pipe Long L600mm), Connection Size: 06 (One-touch Fitting Ø6), Nozzle Diameter: 150 (Ø1.5)

Type: None, Connection Size: 06 (One-touch Fitting Ø6), Material: Metal or None for Type A, AG, Nozzle Diameter: 150 (Ø1.5)

Type: None, Connection Size: 08 (One-touch Fitting Ø8), Material: Metal or None for Type A, AG, Nozzle Diameter: 150 (Ø1.5)

Type: None, Connection Size: 06 (One-touch Fitting Ø6), Material: A (Resin), Nozzle Diameter: 150 (Ø1.5)

Type: None, Connection Size: 08 (One-touch Fitting Ø8), Material: A (Resin), Nozzle Diameter: 150 (Ø1.5)

Double acting, single rod type Cylinder stroke range: 1/8" to 4" Maximum operating pressure: 200PSI Operating temperature range: 15 - 150°F Auto switch capable COMPACT CYLINDER. Compact Cylinder, NCQ8. 385.55350 lb. E46.

A dedicated solenoid valve is not required for unlocking, thus reducing the initial costs and replacement of the existing equipment.Bore size (mm): 32-63, Stroke (mm): 50-150, Can be locked at any position within the entire stroke, Selection of retraction locking & extension locking is possible, Piping not required for unlocking PIN PLATE CYLINDER.

Perform the various settings. (1) Name: Input a unit name of your choice. (2) Comm Format: Select the data format of the Connection Parameters. (3) IP Address: Input the IP Address of the SI unit. (4) Assembly Instance: Set as follows: Input = 100 Output = 150 Configuration = 105 (5) Size: Set as follows: Input = 2 bytes (for Data-SINT) = 1 word (for Data-INT) Output = 4 bytes (for Data-SINT

Safety cannot be assured in the case of unexpected malfunction. 7 3 5 6 9 1 2 4 8 10 0 Blue : 24 VDC (for input and controlling) 118.5 76.5 97.5 108 139.5 55.5 66 87 129 150 L1 45 4 3 Black : 0 V (for input and controlling) 236.8 152.8 194.8 215.8 278.8 L2 110.8 131.8 173.8 257.8 299.8 89.8 Power supply connector Provide grounding to assure the safety and noise resistance of the Fieldbus

Displays the diagnosis status of the unit. 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 IP address is duplicated. Connection timeout. Connection is established. Recoverable error. The unit is in normal operation. The power supply for control and input is Off. The element in SI unit is broken. The power supply voltage for output is abnormal.