Grease pack part numbers: GR-S-010 (Net weight: 10g), GR-S-020 (Net weight: 20g) 1) Piston seal Apply grease to the inner and outer circumferences lightly and evenly for easier mounting onto the piston. 2) Tube gasket Apply grease thinly to prevent the gasket from coming off. 3) O Ring Apply grease thinly to prevent the gasket from coming off. 4) Cylinder components Apply grease to each part
General diagnostics 1 Table. 5-2 General diagnostics 1 Bit Description Explanation 0 System fault 0: No error on Diagnostics data on I/O mapping 1: At least one error on Diagnostics data on I/O mapping has occurred 1 Valve-coil(s) short circuit 0: No valve coil(s) have a short circuit 1: At least one valve coil has a short circuit 2 Module error 0: No module has an error 1: At least one connected
Use this data as a guideline for selection, as the performance data may vary depending on the material and size of the work piece. 1) Discharge characteristics (Discharge time from 1000 V to 100 V) 2) Discharge characteristics range (Discharge time from 1000 V to 100 V) 25 2 Air flow scale: 1 Air flow scale: 2 1 20 3 Air flow scale: 3 Discharge time [s] 15 s 10 5 4 Air flow scale: 4 0 0 300
Response time 1 s or less : Other specifications are equal to standard product. Analogue output A B C Voltage output 1 V 1.5 V (1.4 V) 5 V Current output 4 mA 6 mA (5.6 mA) 20 mA : The value in ( ) is when PF2W711 is used. Rated flow range Model Min. Max.
After 3 s, the mode will reset to the measurement mode. 1 digit of the zero clear range varies with individual product differences. Residual pressure Error Perform zero clear operation again after restoring the applied pressure to an atmospheric pressure condition. Pressure has exceeded the upper limit of the set pressure range.
Grease pack part number: GR-S-010 (10g), GR-S-020 (20g) 3-3. Replacement Parts Refer to the catalog the parts that can be replaced. Warning 1) Maintenance should be performed according to the items above.
Please refer below for calculation of kinetic energy. 2 1 I E E: Kinetic energy [ J ] 2 I: Moment of inertia [ 2 m kg ] : Angular speed [ s rad ] Allowable kinetic energy for the rotary actuator is limited. The limit of rotation time is obtained by calculating the moment of inertia. Please refer below to calculate the moment of inertia.
Specification Seal cap EX9-AWTS For M12 connector socket: 10 pcs. -41No.EX-OMP0013-E Power supply connector (1) Cable with power supply connector Part number: EX500-AP0 1 0S Connector specifications S Straight A Angle Cable length (L) 1 1000 [mm] 5 5000 [mm] EX500-AP0#0-S EX500-AP0#0-A Item Specifications Pin No.
Grease pack part no.: GR-S-010 (10 g) 74
Fittings & Tubing Air Cylinders Rotary Actuators How to Order 11 Vacuum suction type Clean series 11 M D H R 3 10 R M9B S 22 M D H R 3 10 R M9B S Copper, fluorine and silicone-free + Low particle generation Number of auto switches 2 pcs. 1 pc.
Replacement part/grease pack part no. : 20, 25, 32 : GR-S-010(10 g) 40, 50 : GR-S-020(20 g) 713 MHW2 Series Dimensions MHW2-20D Flat finger type (Standard) 20 2 x M5 x 0.8 thread depth 7 (Mounting thread) 17 60 4 x M5 x 0.8 thread depth 10 (Mounting thread) Bottom through hole dia. 4.2 (Mounting hole) 45 2 x M5 x 0.8 thread depth 10 (Mounting thread) 35 23 26 27 36 18 23 7 2 21H9 +0.052 depth
(mm) ND NN Bore 10 16 A B C D F GA GB H MM NA NB S Z 0 0.022 0 0.022 15 12 14 4 8 8 5 28 M4 X 0.7 12.5 9.5 M8 X 1.0 46 74 75 8 15 18 20 5 8 8 5 28 M5 X 0.8 12.5 9.5 M10 X 1.0 47 10 Refer to p.1.3-8 to 1.3-10 for dimensions of each mounting bracket.
P . 15-11-3 15-9-2 2 Speed Controller with One-touch Fitting Elbow Type/Universal Type Series AS How to Order 2 2 0 01 06 S AS 1F Nil Option Body size 1 2 3 4 M3, M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard None With seal Hexagonal lock nut Electroless nickel plated S K N If more than one option is required, write option part numbers in the order of S, K, N.
(N specifications) How to Order AS4200-04 AS3200-03 01 S AS 2 2 0 0 AS2200-02 AS2200-01 Option Body size AS1200-M5 None With seal Nil 1 2 3 4 M3, M5 standard S K N 1 8 1 4 , standard standard standard AS1400-M3 Hexagonal lock nut 8 3 Electroless nickel plated 2 1 If more than one option is required, write option part numbers in the order of S, K, N.
AS ASP ASN AQ ASV How to Order AK D 01 S AS 2 0 0 2 ASS ASR ASF Type adjustable by flat head screwdriver Body size 1 2 3 4 JIS Symbol M5 standard 1/8,1/4 standard 3/8 standard 1/2 standard With seal Note) In case that connecting port is either M5 or 10-32 UNF thread, it is not available with seal. With gasket is provided as standard.
How to Order 2 2 0 0 01 M AS Option Body size None With seal Nil S 1 2 2 Meter-out Meter-in M5 standard 1/8, 1/4 standard Type Direct cylinder elbow type Control type M5 and U10/32 are not available with seal.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com V (mm/s) = Auto switch operating range (mm) Load operating time (ms) x 1000 Current to operate load (OFF condition) > Leakage current If the condition given in the above formula is not met, it will not reset correctly (stays ON).
DENMARK SMC Pneumatik A/S FINLAND SMC Pneumatiikka OY FRANCE SMC Pneumatique SA GERMANY SMC Pneumatik GmbH HUNGARY SMC Hungary Kft. IRELAND SMC Pneumatics (Ireland) Ltd. ITALY SMC Italia S.p.A. NETHERLANDS SMC Pnuematics BV. NORWAY SMC Pneumatics Norway A/S POLAND SMC Industrial Automation Polska Sp.z.o.o. ROMANIA SMC Romania s.r.l. RUSSIA SMC Pneumatik LLC. SLOVAKIA SMC Slovakia s.r.o.
hole F Applicable screw M5 hexagon socket head cap screw M6 hexagon socket head cap screw M8 hexagon socket head cap screw Model AMP220 AMP320 AMP420 E OUT Maintenance space (mm) C B Bracket related dimensions Element service indicator related dimensions Port size (nominal size B) Model A D E I 66 80 90 J K L M N O P Q R S F 80 120 180 G 123 169 237 H AMP220 AMP320 AMP420 76 90 106 76 90
0.4MPa Set pressure range (OFF) 0.08MPa Differential 1a Contact point construction 2VA AC, 2W DC Max. contact point capacity 48V 100V 12V 24V Voltage (AC, DC) 40mA 20mA 50mA 50mA Max. current 1.2ms Operating time 30G Shock resistance JIS symbols w AMR4000 AMR3000 AMR5100 1.9-1 Regulator with Mist Separator AMR3000 to 6000 How to Order Adapter Assembly (part number for one piece) E3 03 R S