Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: Supply: NC, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: Suction Filter, Pressure Sensor Specs: Pressure Sensor, -100 to 100kPa, Accuracy ±1% F.S., Air Pressure Supply
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: Supply: NC, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: M Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S., Air Pressure Supply, P Port
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: Supply: NC, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 12VDC, Electrical Entry: M Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S., Air Pressure Supply, P Port
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: Supply: NC, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S., Air Pressure Supply, P Port
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: Supply: Latching Positive Common, Release: None, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: M Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S., Air
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: Supply: NC, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: Suction Filter, Pressure Sensor Specs: w/o Pressure Sensor, Air Pressure Supply, P Port: ø4, Elbow, Vacuum
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: Supply: NC, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Locking Type, Suction Filter: Suction Filter, Pressure Sensor Specs: Pressure Sensor, -100 to 100kPa, Accuracy ±2% F.S., Air Pressure Supply, P
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: Supply: Latching Negative Common, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Locking Type, Suction Filter: Suction Filter, Pressure Sensor Specs: Pressure Sensor, 0 to -101kPa, Accuracy ±1% F.S., Air
Series ZB compact vacuum unit includes a vacuum ejector, supply valve, release valve, vacuum break flow adjustment needle, suction filter and silencer in a single unit. The ZB is an energy saving design with reduced air consumption and reaches vacuum pressure set point quicker than previous models. The series is constructed with separate vacuum and pressure paths, which effectively reduce
Series ZB compact vacuum unit includes a vacuum ejector, supply valve, release valve, vacuum break flow adjustment needle, suction filter and silencer in a single unit. The ZB is an energy saving design with reduced air consumption and reaches vacuum pressure set point quicker than previous models. The series is constructed with separate vacuum and pressure paths, which effectively reduce
Series ZB compact vacuum unit includes a vacuum ejector, supply valve, release valve, vacuum break flow adjustment needle, suction filter and silencer in a single unit. The ZB is an energy saving design with reduced air consumption and reaches vacuum pressure set point quicker than previous models. The series is constructed with separate vacuum and pressure paths, which effectively reduce
Series ZB compact vacuum unit includes a vacuum ejector, supply valve, release valve, vacuum break flow adjustment needle, suction filter and silencer in a single unit. The ZB is an energy saving design with reduced air consumption and reaches vacuum pressure set point quicker than previous models. The series is constructed with separate vacuum and pressure paths, which effectively reduce
Series ZB compact vacuum unit includes a vacuum ejector, supply valve, release valve, vacuum break flow adjustment needle, suction filter and silencer in a single unit. The ZB is an energy saving design with reduced air consumption and reaches vacuum pressure set point quicker than previous models. The series is constructed with separate vacuum and pressure paths, which effectively reduce
Vacuum ejector series ZA is compact and lightweight, making it ideal for pick and place operations, and suitable to all industries.? Due to the compact design of the ZA, it is possible to install on moving parts.? The shortened tube length to pad improves response time.? The ZA is available as a single unit or manifold type, with or without pressure sensors?and suction filters.? Compact
Series ZB compact vacuum unit includes a vacuum ejector, supply valve, release valve, vacuum break flow adjustment needle, suction filter and silencer in a single unit.? The ZB is an energy saving design with reduced air consumption and reaches vacuum pressure set point quicker than previous models.? The series is constructed with separate vacuum and pressure paths, which effectively reduce
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VACUUM EJECTOR, COMPACT, VACUUM SERIES, ZA COMPACT VACUUM EJECTOR, AG, ZA NOZZLE SIZE 0.5, .22046 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ZA NOZZLE SIZE 0.5, VACUUM SERIES, ZA COMPACT VACUUM EJECTOR, BG, ZA NOZZLE SIZE 0.5, 0.33069 lb
Series CM2-Z double acting, single rod, stainless steel cylinders are compact, lightweight and offer high performance. The piston seal and rod seal designs provide excellent life. Transparent auto switch bracket provides visibility of the status of the switch. The CM2-Z series delivers extra flexibility including the option of male and female rods. Where space is at a premium, you can
Series CM2-Z double acting, single rod, stainless steel cylinders are compact, lightweight and offer high performance. The piston seal and rod seal designs provide excellent life. Transparent auto switch bracket provides visibility of the status of the switch. The CM2-Z series delivers extra flexibility including the option of male and female rods. Where space is at a premium, you can