Element Description EtherNet/IPTM connection PORT 2. 1 (M12 4-pin socket, D-coded) 1 Fieldbus interface connector (BUS OUT) EtherNet/IPTM connection PORT 1. 1 (M12 4-pin socket, D-coded) 2 Fieldbus interface connector (BUS IN) 3 Power supply connector Power supply with load voltage for valves and operating voltage for SI unit. 1 (M12 4-pin plug, A-coded) 4 FE terminal Functional earth.

Compact Cylinder with Air Cushion and Lock 32, 40, 50, 63 Series RLQ How to Order B 32 50 M F RLQ RDLQ M9BW B 32 50 M F With auto switch Number of auto switches With auto switch (Built-in magnet) Auto switch Mounting style 2 pcs. 1 pc. n pcs.

1 Note) There is no protrusion for sections of the table with no values entered. 6.5 6.5 6.5 6.5 0.5 0.5 3 3 1 1 4.5 4.5 4.5 4.5 1 1 6.5 6.5 6.5 6.5 0.5 0.5 3 3 1 1 Hysteresis MHF2-8D D-M9(V) D-M9W(V) MHK MHF2-8D1 Red ON Green ON MHF2-8D MHS 0.5 0.5 1 MHF2-8D2 MHF2-12D 0.5 0.5 1 MHC MHF2-16D 0.5 0.5 1 MHF2-12D MHF2-20D 0.5 0.5 1 MHT MHF2-12D1 MHY Mounting of Auto Switch MHF2-12D2 MHW Insert

9 Parallel pin o Cap B Aluminium alloy Clear anodized NBR @0 Piston seal !0 Cap C Urethane rubber NBR @1 Gasket !1 Head damper Stainless steel Nit riding NBR @2 Gasket !2 Rack Replacement Parts Bolts for Body Through-hole Mounting Description Kit no.

Part name Material Qty Remarks 1 Cassette POM,Stainless steel304 2 Blue 2 Body PBT 1 Red 3 Seal NBR 2 4 Valve HNBR 1 5 Valve guide Brass 1 6 Rod Brass 1 7 Push Button POM 1 Red 8 Spring Stainless steel304-WPB 1 9 Push nut Stainless steel304 1 Rc thread with a push button guardKEC No.

Body size 1 2 3 4 M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard Applicable tubing O.D.

(full span/full scale) This means "full span" or "full scale", and indicates varied analogue output range at rated value.For example, when analogue output is 1 to 5 V, F.S.=5[V] 1[V]=4[V]. (Reference: 1%F.S. = 4[V] 1% = 0.04[V]) I Instantaneous flow The flow passing per unit of time. If it is 10 L/min, there is a flow of 10 L passing through the device in 1 minute.

*sure dlsplay Accuracy J3% (lull span) Minimum unit [ i l P a : 0 . 0 1 . k a f / c m ' : 0 . 0 1 , b a r : 0 . 0 1 .

Energization of a 2-Position Double Solenoid Valve To avoid operation failure, do not energize the A side and B side of 2-position double solenoid valve at the same time. Tube attachment/detachment for One-touch fittings Caution Caution 1) Tube attachment 1. Take a tube having no flaws on its periphery and cut it off at a right angle.

is nol otfered on trunion or clevis mount cylinders Bore Stsoke O25-1/ainch a37-/eirch Ofi_r/zinch O75 3/ainch Stroke o6 (1h,) O'tO (Es"\ q15 (SB'I % , % , % , % % , % , ' / r , % , ( Y , 1 % 1OO-1 inch 125-11/4inch '{r inch soacer is added to the 1 % inch strcke cylinder o Series NCJP a :Available X : Not available Standard Accessories 8.8 PSI (0.6k97cm.) 20 PSI (1.2kgflcmr) 100 PSI (7kgf

B [mm] 11 S coupler KK4P-03MS 35.7 H06 Metric size One-touch fitting 6 KQ2H06-03AS 13 H08 8 KQ2H08-03AS 13 H10 10 KQ2H10-03AS 18.4 H07 Inch size One-touch fitting B B 1/4" KQ2H07-36AS 13.4 H09 5/16" KQ2H09-36AS 13.4 H11 3/8" KQ2H11-36AS 18 With S coupler plug mounted (KK4P-03MS) With One-touch fitting mounted (KQ2H AS) -3- 4.External dimensions Long nozzle(Option) L + 7 Reference dimension

Setting using System Manager 1. Copy the XML file *1 for this unit to the following folder: C:TwinCATloEtherCAT (this path is valid only when the default setting is kept.) Start up the TwinCAT System Manager after copying. 1: The XML file for this product can be found on the SMC website (URL http://www.smcworld.com). 2. Network setting 2-1. Off-line manual configuration method 2-1-1.

Element Description PROFINET connection PORT 2. 1 1 Fieldbus interface connector (BUS OUT/Port2) (M12 4-pin socket, D-coded) PROFINET connection PORT 1. 1 2 Fieldbus interface connector (BUS IN/Port1) (M12 4-pin socket, D-coded) 3 Power supply connector Power supply with load voltage for valves and operating voltage for SI unit. 1 (M12 5-pin plug, A-coded) 4 FE terminal Functional earth.

Note that the application of excessive torque may break the needle valve. 1/8 0.060.17 1/4 0.060.23 3/8 0.100.25 1/2 0.100.40 Mounting Caution (1)When performing the piping work, turn the tightening tool in the horizontal direction to the hexagon across flats of the body B so that any moment is not applied to the body.

Rc 1/8 Body ported 80 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 M5 x 0.8 130 (Without subplate 80) N.C. Base mounted (with sub-plate) SYJA724-01 SYJA724-02 N.O.

NVEP NVEF 3 1 r T 1 0 3 4 0 T I tffi IFTC I B"dt nowj I Rate rype I I Ports Port Size Code Max. Etfective Orifice (mm2) NPTF (Base mount type) 1 1 3 02=1h 03 = 3/s I .t 1 30 Q2=1/t 03=9e O4=1/z 1 45 03 =3/8 04=1/z 06=aa (Base mount type) 1 2 02=lL 03 = 3/s 8 4.5 4 ?.

Assy 3-4 3-5/ -1- 1) 2) (ISO/IEC) (JIS) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218-1992: Manipulating industrial robots -Safety JIS B 8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433-1993

370 440 100 120 130 160 180 210 246 290 ITVX 1 4, 3 8, 1 2 1 4, 3 8, 1 2 1 2, 3 4 1 2, 3 4 PVQ 3 4, 1 3 4, 1 VY1 Adapter Assembly Installation Procedure Accessory/Compact Pressure Switch: IS10-01 For details, refer to Best Pneumatics No. 8.

Example wiring is shown in the figure b. : Bit status 0 and 1 in the data corresponds to solenoid valve status OFF and ON (0: OFF, 1: ON), and the output number starts at zero from LSB (least significant bit). (3) Fuse disconnection details The power supply fuse disconnection for the SI unit solenoid valves can be monitored by the link special register of the master station. 0: Normal 1: