Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket
(Representative valve) Ambient and operating air temperature -5 to 60 oC (No freezing) C(dm3/(sbar)) 0.6 [1(P) 2(A)] , 0.5 [2(A)3(R)] Flow rate characteristics b 0.2 [1(P) 2(A)] , 0.15 [2(A)3(R)] Port size Rc, NPT, G1/8 ON timing ON upon the set delay Output method Normal close Reset Resets by exhausting the input signal pressure Weight 480g *) The dispersion is shown excluding the first
Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with a switching element or when a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the leakage voltage passing through the C-R circuit. The suppressor residual leakage voltage should be as follows. DC coil 3% or less of the rated voltage 6.
Description Cover Piston Collar Return spring Piston seal Gasket Mounting nut Rod end nut Note Electroless nickel plated Material Brass Stainless steel Brass Piano wire NBR NBR Brass Steel No. q w e r t y u i Zinc chromate Special product (O ring) Plug mounting only Electroless nickel plated Nickel plated Provided Nut/Part No.
As a result, the vacuum pressure valve t which is linked to the diaphragm r opens, VAC and OUT are connected, and the set pressure becomes negative. This negative pressure feeds back to the control circuit i via the pressure sensor u.
External Feedback Lever (IP5000 type) Stroke Order Code Unit Number Size M Size N P378010-11 150 125 10~85 mm (Nil) P378010-12 195 110 35~100 mm (E) P378010-13 275 110 50~140 mm (F) DIMENSIONAL DRAWINGS S E R I E S I P 5 0 0 0 / I P 5 1 0 0 IP5000 TYPE: LEVER TYPE LEVER FEEDBACK IP5100 TYPE: ROTARY TYPE CAM FEEDBACK IP5100 TYPE: NAMUR ADAPTER PLATE (Part Number: PAP5100-3) NAMUR MOUNTING
SMCs analog outputs are all of the voltage variety, but tests have proven that there is no problem in applications of 10 [m] or less.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Bracket (Option) 2-M4 x 0.7 depth 7 Main port Rc Model VND10D-6A VND10D-8A VND10D-10A 1 8 1 4 3 8 Port size 10A, 15A, 20A, 25A G (Valve open) Pilot port Indicator (Option) (Back side P2) Bracket (Option) Main port Main port Rc A B C D E F G M N P Q R
0 PVQ o r VY1 VBA VBAT AP100 Drain Port size 1 4 Drain Component Parts Replacement Parts No. Description AMR3000 AMR4000 AMR5000 AMR6000 Model Material Qty Part no. Description No.
CJ2-Z Series 10, 16 Air Cylinder 10-/1121-/22RoHS How to Order Cushion Clean series 10 11 Relief type Vacuum suction type Rubber bumper (Standard) Air cushion Nil A 10 D L 16 60 A R C J 2 M9BW Z B 21 D L 16 60 R C J 2 M9BW Z B Number of auto switches Nil Built-in magnet Head cover port location 2 pcs. 1 pc. n pcs.
CJ2-Z Series Air Cylinder/10, 16 10-/1121-/22How to Order Cushion Clean series 10 11 Relief type Vacuum suction type Rubber bumper (Standard) Air cushion Nil A 10 D L 16 60 A R C J 2 M9BW Z B 21 D L 16 60 R C J 2 M9BW Z B Number of auto switches Nil Built-in magnet Head cover port location 2 pcs. 1 pc. n pcs.
Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with switching element or a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the passing leakage voltage through the C-R circuit. The suppressor residual leakage voltage should be as follows.