Note Ground the FG terminal with a ground resistance of 100 or less. Tighten the FG terminal (M3 round head combination screw) firmly with a tightening torque of 0.3 Nm. Tighten the connector fixing screws (M2.5 slotted head screws) firmly with a tightening torque of 0.2 to 0.3 Nm. A. Dual power supplies B.
No code A 1) Only available with AP501.
A in the graph shows the A position when the time delay is set to 60 seconds for a input Time delay (sec) signal pressure of 0.25 MPa. The B time delay will be changed to position B (approximately 40 seconds) when the input signal pressure is increased to 0.8 MPa.
(a) Correct mounting of V-band Fig. (b) Incorrect mounting of V-band (Not correctly fit with collar of cover (1) Mount V band to the collar of the cover and the case correctly. [Refer Fig. (a), (b) Warning The cover may be fallen off due to incorrect mounting.
The product utilizes a corona discharge and generates a slight amount of ozone and NOx. If it is used in a closed space, ozone is concentrated so much as to possibly affect human body. Therefore, it is necessary to set up a ventilation system in the space.
1 2 4 3 2 1 110 VAC 50/60 Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz Symbol A: Non-locking push type A (projecting) N.C. 0.5 MPa N.O. 1 MPa N.C. 1 MPa 4 1 6A 8A 10A 10A 15A 20A 25A 32A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz Valve size 1 7 5 6 24 VDC 12 VDC B: Slotted locking type B (tool required) 7 240 VAC 50/60 Hz 15 (11) 2 Semi-standard For other rated voltages, please consult with SMC
F.S.=100-0=100[kPa] 1.0F.S.=1000.01=1[kPa] 4951[kPa]ON () 1[F.S.],51[kPa]ON 5052[kPa]ON4951[kPa] 50[kPa]() 50[kPa] ON 50[kPa]1.0 [F.S. ]ON ON ON ON 0 0.01 MPa 0.00,0.01,0.02,0.015,0.025 () 0() 0 -11No.PS-OMH0002CN-D () SI ON-OFF ONOFF ON-OFF ON (LED) () " ()" ON-OFF ON () -12No.PS-OMH0002CN-D ISE7013.615 NmISE75/75H2528 Nm (24 mm) (ZS-31-A) B M6 5 mm B (ZS-31-A) -13No.PS-OMH0002CN-D
VQC series: ES11-8 Compact design with high flow capacity Flow characteristics Note) Dual 3 Port valves, 4 positions Metal seal Applicable cylinder size (mm) Model (Series) Manifold pitch (mm) Rubber seal b C[dm3/(sbar)] Cv b C[dm3/(sbar)] Cv 1) Two 3 port valves built into one body. 2) The 3 port valves on the A and B sides 3) When used as a 3 port valves, only ha 4) Three types of combinations
B 0.2 A 0.2 Bore size [mm] A [mm] B [mm] Hexagon socket head cap screw 12 (10 x 2) 52 11 M3 x 0.5 16 (12 x 2) 57 11 M4 x 0.7 20 (16 x 2) 75 14 M4 x 0.7 25 (20 x 2) 84 17 M5 x 0.8 32 (25 x 2) 98 21 M6 x 1.0 40 (32 x 2) 107 27 M8 x 1.25 50 (40 x 2) 135 37 M8 x 1.25 63 (45 x 2) 146 40 M10 x 1.5 80 (56 x 2) 184 50 M12 x 1.75 100 (71 x 2) 219 62 M14 x 2 7.
Bore d C B H NTJ-015A 10 16 8.1 9.2 7 8 3.2 4 M4 X 0.7 NTJ-010A M5 X 0.8 * Refer to p.1.3-12 for details of the mounting nut. (mm) ND NN Bore 10 16 A B C D F GA GB H MM NA NB S Z 0 0.022 0 0.022 15 12 14 4 8 8 5 28 M4 X 0.7 12.5 9.5 M8 X 1.0 46 74 75 8 15 18 20 5 8 8 5 28 M5 X 0.8 12.5 9.5 M10 X 1.0 47 10 Refer to p.1.3-8 to 1.3-10 for dimensions of each mounting bracket.
single 1 4 Power saving circuit is not available for D, DO, Y, YO or W types. 10-SY9000 (A)4 2(B) 3 8 1 F2: With side bracket One-touch fitting (Metric size) 1 (P) (EA)5 3(EB) Symbol Port size Applicable series For DC 2 position double 4 One-touch fitting C4 10-SY3000 2(B) (A)4 5 24 VDC 6 12 VDC 6 One-touch fitting C6 2 4 One-touch fitting C4 (EA)5 1 (P) 3(EB) V 6 VDC 6 One-touch fitting
1.41.6Nm 8 2 VR2110 3 01.0MPa 0.250.8MPa 0.560s (*) 10 (%) F.S. oC( -560 3/ (s C (dm 0.6 [1 (P) 2 (A) ] 0.5 [2 (A) 3 (R) ] bar) ) b 0.2 [1 (P) 2 (A) ] 0.15 [2 (A) 3 (R) ] Rc, NPT, G1/8 ON Delay 480g (*) 4 4 V R 2 1 1 0 01 01 Rc 1/8 N01 NPT 1/8 F01 F01 2 G 1/8 9 5 VR 1 ON Delay 0.560 () () 1 ON OFF 6 (1) 2 0.5MPa 2 10 (2) VR2110 3 )0.25MPa A 60sec (), (S) 0.8MPa 40sec
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Z A B . Oct X QX RX SX . ZX AX BX . T With stand for vertical installation 8 1 15 9 D-sub 15 pin (Socket type) Fixed screw: M2.6 Description No.
Valve type Symbol Nil A G H L Body material Coil insulation Seal material NBR FKM NBR FKM FKM N.C. (2) N.O. (3) Brass Class B Stainless steel 50 Note) (1) IN Note) For pure water: The armature assembly is a corrosion resistant construction.
Fig. 3-2 [Ex.-2] 5 B Load base Guide shaft Bearing A External slider Cylinder tube Detail of A Wrong example Correct example View A Load base Load base External slider Spacer Clearance External slider Detail of B Detail of B By tightening of the bolt, the load base and Insert the spacer to keep flexibility in cylinder body and load base even after the bolt is tightened. cylinder body are
How to Order VHS 30 03 D Semi-standard: Select one each for a to b. Semi-standard symbol: When more than one specifications is required, indicate in alphanumeric order.
) B C Panel type One-touch fitting feature introduced to series mm Weight Model A (Width) C (Depth) B (Height) Approx. 70g (Body: 65g) 4, 6 (metric size) 5/32", 1/4" (inch size) ARJ310-01G 18.3 Approx. 41 82.5 Approx. 75g (Body: 60g) ARJ210-M5G 18.3 80 Approx. 46 Miniature Regulator Series ARJ310 How to Order Port size (IN, OUT) 1/8 (male thread), M5 x 0.8 (female thread) 1/8 (female thread
2 1 (A P) Flow characteristics Weight (g) Operating pressure range (MPa) 1 2 (P A) 2 3 (A R) Port size Valve model C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv Grommet 0.44 0.40 0.40 0.44 0.40 0.41 0.63 0.63 0.41 0.63 0.13 0.10 0.10 0.13 0.10 0.20 0.14 0.14 0.20 0.14 VK332 0.47 0.41 0.41 0.47 0.41 0.85 0.65 0.65 0.85 0.65 0.47 0.38 0.38 0.47 0.38
Air tank 41l PA=0.7 MPa A=0.7 MPa Air tank 20l PA=0.7 MPa Air tank 20l PA=0.7 MPa A=0.7 MPa Air tank 41l PA=0.7 MPa Air tank 20l PA=0.7 MPa A=0.7 MPa Air tank 20l PA=0.7 MPa 6 x 6 pcs.