P A B C D G J M N Q R S T U V B AM50 3/41 90 237.7 32 45 30 45 70 66 40.5 11 13 113 3.2 52.5 259.2 AM60 1 90 314.8 32 45 30 45 70 66 40.5 11 13 113 3.2 52.5 336.3 Semi-standard specifications SUS bowl Model No.
P A B C D G J M N Q R S T U V B AMD50 3/41 90 237.7 32 45 30 45 70 66 40.5 11 13 113 3.2 52.5 259.2 AMD60 1 90 314.8 32 45 30 45 70 66 40.5 11 13 113 3.2 52.5 336.3 Semi-standard specifications SUS bowl Model No.
W a r n i n g As a minimum, maintenance should be performed according to the above items. Perform additional maintenance as necessary. Improper handling can cause damage and malfunction of equipment and machinery. Removal of equipment, and supply/exhaust of compressed air.
Settings1 Intermediate reinforcing brace (EX600-ZMB2) 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 Mode Diagnostic size set for the input Content 2 Vibration resistance NOTE for 2 hours each in direction X, Y and Z respectively (De-energized) 0 OFF 0 byte Input data only (default setting) 147 m/s2 3 times each in directions of X, Y and Z respectively
Safety cannot be assured in the case of unexpected malfunction. : This switch can be enabled and disabled by parameter. 10 to 57 Hz constant amplitude 0.75 mm p-p 57 to 150 Hz constant acceleration 49 m/s2 for 2 hours each in direction X, Y and Z respectively (De-energized) Vibration resistance Diagnostic mode setting switch: Allocates the diagnostic data to the input data.
For use pollution Degree 3 Environment (UL508) Pollution degree Refer to the SMC website (URL https://www.smcworld.com) for more information about these settings. 10 to 57 Hz constant amplitude 0.75 mm p-p 57 to 150 Hz constant acceleration 49m/s2 2 Vibration resistance Operator for 2 hours each in direction X, Y and Z respectively (De-energized) (3)Connecting the SI unit.
Aug V AV BV CV DV EV FV . Sep W AW BW CW DW EW FW . Danger In extreme conditions, there is a possibility of serious injury or loss of life. When the circulating fluid temperature is low, do not operate it at a low Oct X AX BX CX DX EX FX . flow rate. It may freeze circulating fluid in the product when used at low temperature and low flow rate. Nov y Ay By Cy Dy Ey Fy .
Year Month T : 2015 o: January U : 2016 P: February V : 2017 Q: March W: 2018 R: April X : 2019 Z: December -7- 5. Precautions for handling Fluid Warning (1) The operating fluids must be compressed air.
Year Month T : 2015 o: January U : 2016 P: February V : 2017 Q: March W: 2018 R: April X : 2019 Z: December -7- 5. Precautions for handling Fluid Warning (1) The operating fluids must be compressed air.
Description Material PBT Brass Brass Note) Handle Needle Lock nut Needle guide Washer O-ring Silencer Silencer cover Body B Gasket q w e r t y u i o !
N P C37 Stainless steel 25 1 K 200 VAC D N.O. L 230 VAC 7 32A N.C. Q CAC408 35 32A Flange M Conduit terminal 24 VDC E N.O. With surge voltage suppressor N 100 VAC 8 40A N.C. R CAC408 40 40A Flange P 110 VAC F N.O. Q 200 VAC 9 50A N.C. S CAC408 50 50A Flange R 230 VAC G N.O.
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking Push Type, Vacuum
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking Push Type, Vacuum
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N04 [Vacuum: 2 x NPT1/2 (Branch Spec.); Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: E (Push-turn
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking Push Type, Vacuum
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking Push Type, Vacuum
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking Push Type, Vacuum
Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N04 [Vacuum: 2 x NPT1/2 (Branch Spec.); Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking
Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 04 [Vacuum: 2 x Rc1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking
Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N04 [Vacuum: 2 x NPT1/2 (Branch Spec.); Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking