Weight (Cylinder Without Clamp Arm) [kg] Bore size Arm position Arm opening angle Additional weight of the manually operated handle 15 30 45 60 75 90 105 120 135 50 R/L 3.3 3.3 3.3 3.3 3.2 3.2 3.2 3.2 3.2 1.7 D 3.4 3.3 3.3 3.3 3.3 3.3 3.3 3.2 3.2 63 R/L 4.6 4.6 4.5 4.5 4.5 4.4 4.4 4.4 4.4 1.7 D 4.7 4.7 4.6 4.6 4.6 4.5 4.5 4.5 4.5 Cylinder Stroke [mm] Bore size Arm opening angle 15 30 45 60
60 70 X 10 15 18 22 28 35 40 50 60 LD 3.5 3.5 4.3 5.4 5.4 7 7 8.6 8.6 WP 9.5 13 16 19 21.5 27 32 41 47 Y 35.5 39.5 54.5 64 72 79 93 113 121 Z 66 76 94 107 117 130 148 176 188 M 3.5 4 5 5 6 7 8 10 10 MM M3 x 0.5 M3 x 0.5 M4 x 0.7 M4 x 0.7 M5 x 0.8 M6 x 1 M6 x 1 M8 x 1.25 M8 x 1.25 N PW 19 26 32 38 43 54 64 82 94 Q 60 68 84 95 105 116 134 159 171 QW 10 14 18 17 20 26 34 48 60 T 14.5 17.5 19
20 40 0 60 20 40 0 60 80 CY1F Moment (Nm) Moment (Nm) Moment (Nm) Note) Indicates the displacement (rigidity) on the slide table from the position where the reaction force is generated when the torque is applied to the slide table.
[Option] Electrical entry D: DIN terminal DO : DIN terminal (Without connector) G: Grommet (Lead wire length: 300 mm) H: Grommet (Lead wire length: 600 mm) Rated voltage Valve option Rated voltage Nil V Y W E DC AC CE-compliant 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz For the connector part number, refer to page
Electrical entry Rated voltage G Grommet 2 200 VAC 50/60 Hz 1 100 VAC 50/60 Hz C Conduit D DIN terminal 3 110 VAC 50/60 Hz T Conduit terminal 4 220 VAC 50/60 Hz 7 240 VAC 50/60 Hz Refer to the table (1) given below for availability. 8 48 VAC 50/60 Hz 9 Other (Only AC) Table (1) Rated VoltageElectrical Entry-Electrical Option Caution Insulation type Electrical entry Electrical option 1 (100
60 50 to 65 50 to 60 1 Compliant with the FDA (USA Food and Drug Administration) regulation 21CFR177.2600 for Rubber articles intended for repeated use 2 Compliant with the standards for Rubber apparatus (excluding baby drinking apparatus) and containers/packaging (D3) (Partial revision: Ministry of Health, Labour, and Welfare Notification No. 595, 2012) in Section 3 Apparatus and Containers
Example: 3) From Table 2, determine Stop Tube Requirements ~ 1) From Table 1, determine Stroke Factor (SF) ~ NCDA1L800-6000-XTATCDN Find L length and note Stop Tube length Stroke Factor 2.0 8 Bore Stop Tube Length = 8 60 Stroke 2) Determine Effective Length L MS1 Mount L = Stroke x Stroke Factor Supported but not rigidly guided = 60 x 2.0 = 120 inches 21 Engineering Specifications Expanded
Low Speed Cylinder Double Acting, Single Rod Series CJ2X 10, 16 How to Order Bore size 10 16 10 mm 16 mm Standard stroke (mm) 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate stroke other than above is manufactured upon receipt of order.
OUT 113 23 34 45 57 68 79 90 102 113 12 6 IN 85 17 26 34 43 51 60 68 77 85 OUT 201 40 60 80 101 121 141 161 181 201 Symbol Specifications 16 8 IN 151 30 45 60 76 91 106 121 136 151 -XA Change of rod end shape OUT 314 63 94 126 157 188 220 251 283 314 Heat resistant cylinder (150C) -XB6 20 10 Low speed cylinder (10 to 50 mm/s) -XB9 IN 236 47 71 94 118 142 165 189 212 236 Intermediate stroke
Guide for Using MY3B Side Support Guide for Using MY3A Side Support 100 100 90 90 (1800) (1900) 80 80 m 70 70 MY3A63 Weight w (kg) 60 60 MY3B63 Weight w (kg) l 50 50 (1300) (1400) 40 40 MY3B40 MY3A40 30 30 m 20 20 (1000) (1100) l MY3B25 MY3A25 10 m 10 (900) (1000) MY3A16 MY3B16 0 0 4000 3000 2000 1000 0 4000 3000 2000 1000 0 Support spacing l1 (mm) Support spacing l1 (mm) Note) A side support
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, GUIDE, DUAL STK, ACTUATOR, MGG GUIDED CYLINDER, HC, 20MM MGG OTHERS (COMBO), .00000 lb, SeriesDescriptionModelActionNoteVol. no. (for std model)MGGGuide cylinderMGGDouble actingExcept with shock absorber, with rubber cushion--8--
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
0.5 50 Circulating fluid outlet Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 Usable flow rate range 0.2 20 Circulating fluid return 0.1 10 0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Circulating fluid flow [L/min] Fig. 8-9 Pump capacity(HRL100-A-20 CH1) 8.5.2 HRL200A20 CH1 0.6 60 0.5 50 Circulating fluid outlet Lifting head [m] Pressure [MPa] 0.4 40 0.3 30 Usable flow rate range 0.2 20
This product Your system Write or read Monitoring 60 sec. time Write or read Monitoring 60 sec. time Passage of 180 sec. Excess at no 60 sec. Broken communicatio wire n monitoring o r time. coming 60 sec. off AL19 Communication error is generated.
This product Your system Broken AL34 Communication wire alarm is generated. o r 60 sec. coming off Communication alarm automatic restoration Normal connection 60 sec. Write or read Monitoring time 60 sec. Write or read Monitoring time 60 sec.
This product Your system Broken wire o r coming off AL19 Communication error is generated. 60 sec. Communication error automatic restoration Normal connection 60 sec. Write or read Monitoring time 60 sec. Write or read Monitoring time 60 sec.
This product Your system Broken AL34 Communication wire alarm is generated. o r 60 sec. coming off Communication alarm automatic restoration Normal connection 60 sec. Write or read Monitoring time 60 sec. Write or read Monitoring time 60 sec.
This product Your system Broken AL34 Communication wire alarm is generated. o r 60 sec. coming off Communication alarm automatic restoration Normal connection 60 sec. Write or read Monitoring time 60 sec. Write or read Monitoring time 60 sec.
This product Your system Write or read Monitoring time 60 sec. Write or read Monitoring time 60 sec. 180 sec passed No communication monitoring time 60 sec. Broken wire exceeded. o r Broken wire 60 sec. AL19 Communication alarm is generated.