Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: Standard, Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 12N (1 + 2 + N), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: BC (B + C), Semi-Standard 1: 12N (1 + 2 + N), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: BC (B + C), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: BG (B + G), Semi-Standard 1: 12N (1 + 2 + N), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: BG (B + G), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: C (N.C. Float Type Auto Drain), Semi-Standard 1: 12N (1 + 2 + N), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: C (N.C. Float Type Auto Drain), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: RZ (R + Z)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: C (N.C. Float Type Auto Drain), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: 12N (1 + 2 + N), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: BCG (B + C + G), Semi-Standard 1: 12N (1 + 2 + N), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: CG (C + G), Attachment: KV (K + V), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: RZ (R + Z)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: C (N.C. Float Type Auto Drain), Attachment: KV (K + V), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: RZ (R + Z)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 1 (100VAC 50/60Hz), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: 01 (1/8), Thread: Rc (or M5
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 1 (100VAC 50/60Hz), Lead Wire: G (Grommet Lead Wire 300mm), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: E (Push-turn Locking Lever Type), A, B Port Size: 01 (1/8), Thread
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 1 (100VAC 50/60Hz), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: 01 (1/8)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 1 (100VAC 50/60Hz), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: 01 (1/8), Thread: F (G)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 1 (100VAC 50/60Hz), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: 01 (1/8), Thread: Rc (or M5), Bracket