SMC Corporation of America
Elite Part Number Search
Search Results "VVEXB-2-6-01T"

1 5 10 20 0.5 1 5 10 20 Load (kN) Load (kN) 27 Hydraulic Cylinder Technical Data Series CH2E/CH2F/CH2G/CH2H Limit stroke charts/Bore sizes 50, 63, 80, 100 Bore size 50 B rod C rod 2000 5 2 4 8 3 7 2 4 8 3 7 5 6 1 6 1 1000 Stroke (mm) 500 100 50 0.5 1 5 10 20 30 0.5 1 5 10 20 30 Load (kN) Load (kN) Bore size 63 B rod C rod 2000 1 2 8 5 4 3 7 6 1 2 3 5 4 8 7 6 1000 Stroke (mm) 500 100 50

assembly Bumper retainer seal -2, -8 -2, -8 Standard -2 -3 -6 -8 -1 -1S-1 -1S-2 NBR C4SL C4SL-2 C4SL-3 C4SL-6 C4LL-8 800147AP 800147A-S1P 800147A-S2P O-ring 15 1 NBR C4SFP-260S C4SFP-260S Case assembly Note 2) 14 1 Note 1) Description: Bumper assembly Note) O-ring !

Terminal block numbers 5 6 7 8 4 3 2 1 The applicable panel thickness is 1 to 3.2 mm.

D Note 2) Note 1) Bore size: 20, 25 mm only Function Mounting brackets are included when shipped, but unassembled. (Except for clevis type.) Nil H Note) Standard type High speed/High frequency type (Without fixed orifice) Note 2) 6, 10, 16 . Integrated type 20, 25 . Non-integrated type Note) Except for 6 mm bore size.

(torque = 0.3 Nm) F-Address bit No. 4 3 2 1 0 7 6 5 ON PCB OFF 128 64 32 16 8 2 4 1 F-Address Fig. 6-3 PROFIsafe address switch value Note: The F-Address bit numbering shown on the label has priority over any numbers printed on the DIP switch. The default state (factory setting) for this DIP switch is all OFF. 32 No.EX##-OMY0011-A 7. Accessories 7.1.

Total Land Area: 55,647m 2 Floor Space: 23,022m 2 Total Land Area: 124,227m 2 Floor Space: 17,204m 2 Tohno Factory (Iwate Prf.) Total Land Area: 60,638m 2 Floor Space: 10,622m 2 Tsukuba Factory (Ibaragi Prf.)

Bracket (for VFA1000 double) DXT144-8-1A (With 2 mounting screws) 1501 VFA1000/3000/5000 Series Dimensions: VFA1000 Series/Body Ported 2 position single VFA1120-M5(-F)(-P) 2 position double VFA1220-M5(-F)(-P) (11.7) (11.7) (Distance between ports) (Distance between ports) 38 M5 x 0.8 [4 (A), 2 (B) port] M5 x 0.8 [4 (A), 2 (B) port] 26.4 (4) 6 14.8 5 B 2 B 2 26.4 10 10 1/8 (Pilot port: Upward

for setting OFF time DIP switch for setting cascade Digital switch for setting ON time DIP switch for setting two-time hitting Rotary switch for setting output Terminal block for cascade connection OFF ON IN2 IN1 OUT2 OUT1 SW2 SW1 2 F 3 0 9 8 7 6 5 4 3 2 1 1 SW8 0 0 0 0 0 0 1 F O F F O 9 2 8 3 7 4 6 5 0.01 to 0.99 0 to 299 sec sec LED 11 OUT LED 12 CAS LED 13 IN LED 14 POW LED6 LED5 LED4

Nm (mm) 20 1.5 2.0 0.5 25 2.9 2.0 0.5 32 2.9 2.0 0.5 40 4.9 2.0 0.5 50 11.8 5.0 1.0 63 24.5 5.0 1.0 80 24.5 20.0 2.0 100 42.2 20.0 2.0 6 7 8 9 2-4. 1 2) 3 4 5 6 7 11 1 2 3 1.5~2 2 2. 12 2-5. ,AS 2-6. 2-6-1. CG5N 2-6-2. CG5A 11~2 2 31 4 5 6 7 13 2-6-3.

Example of Selection 2021 Chapter 6: Specifications 6-1. Cylinder Specifications 22 6-2. Sensor Specifications 22 Chapter 7: How to Order 7-1. Cylinder 23 7-2. Controller / 3 Points Preset Counter 23 7-3. Extension Cable 24 7-4. Specifications of Made to Order ML2B 2425 Chapter 8: External Dimension Drawing 8-1. Hyrodless Monosashi-kun (with Brake, scale) 26 8-2.

a M O DE SET1 SET2 Maximum suction flow AMJ 2 0 0 4 6 8 10 0.1 0.2 0.3 0.4 0.5 0.6 Suction flow (l/min(ANR)) Supply pressure (MPa) Misc.

5-1 5.2 . 5-2 5.2.1 . 5-2 5.2.2 . 5-2 6 . 6-1 6.1 . 6-1 6.2 . 6-4 IDFC60/70/80/90 Series IDX-OM-W095 7 . 7-1 7.1 . 7-1 7.2 GWP . 7-2 7.3 . 7-3 7.4 . 7-4 7.5 . 7-5 8 C . 8-1 8.1 . 8-1 8.2 . 8-1 9 L . 9-1 9.1 . 9-1 9.2 . 9-1 9.3 . 9-2 9.4 . 9-2 10 R . 10-1 10.1 . 10-1 10.2 . 10-1 10.3 . 10-2 11 T . 11-1 11.1 . 11-1 11.2 . 11-1 11.3 . 11-2 11.4 . 11-3 11.5

Refer to the table below if spacers are required separately. 2 Size 2 2 3 3 4.5 4 6 2 1/4 3 3/8 3 Size 3 3 4.5 4 6 2 1/4 3 3/8 Electrical entry DC AC Female thread type 1 Size 1 1 2 2 3 1 1/8 G Grommet 2 Size 2 2 3 3 4.5 2 1/4 *1 GS Grommet (With surge voltage suppressor) 3 Size 3 3 4.5 4 6 3 3/8 D DIN terminal (With surge voltage suppressor) Fitting type Face seal fitting/Compression

2.5 Width across flats 6 E 5 6 5 Prepared hole diameter 3.3 2-M4 x 0.7 Piping port 2-M3 x 0.5 (Plug: M-3P) F 6 QL 13.5 17 0.05 Stroke: S M 2 M4 x 0.7 Mounting base side B D 7 5 2-M3 x 0.5 Piping port Y J 3 M3 x 0.5 Vacuum suction port Z Max. 9.5 (Rubber stopper) 2.4 depth 2 2.5 3.5 +0.030 0 7 +0.030 0 depth 2 2.5 Q QL Without magnet and switch rail 2 2-M2 x 0.4 depth 2.2 12 Metal stopper

D K 8 8 0 P 0 1 M D K 9 0 S 0 1 M D K KDM20 8 / 1 1 0 P 0 2 M D K 1 0 S 0 2 M D K 2 . 3 3 2 P 0 2 M D K 1 0 S 0 2 M D K e u l B 2 3 / 5 3 0 P 0 2 M D K 3 0 S 0 2 M D K 4 4 0 P 0 2 M D K 3 0 S 0 2 M D K 0 2 d e R 4 / 1 7 0 P 0 2 M D K 7 0 S 0 2 M D K 6 6 0 P 0 2 M D K 7 0 S 0 2 M D K 6 1 / 5 9 0 P 0 2 M D K 9 0 S 0 2 M D K 8 8 0 P 0 2 M D K 9 0 S 0 2 M D K Applicable Tube Material

(mm) M5 M5 4 4 Port size R Port size R 1 8 1 8 6 6 1 4 1 4 8 8 3 8 3 8 10 10 1 2 1 2 12 12 Flame Resistant Type (UL-94 Standard V-0 equivalent) 1(P): One-touch fitting 2(A): One-touch fitting 1(P): Male thread 2(A): Male thread 2(A) 2(A) Port size R Applicable tubing O.D. (mm) 1 8 1 4 3 8 1 2 1(P) 4 6 8 10 12 1(P) Applicable tubing O.D.

Safety Instruction .2 2. Outline.6 3. How to Order.7 4. Specification.7 5. Mounting .7 5-1. Electrostatic sensor installation.7 5-1-1. Sensor head installation.7 5-1-2. Installation of the sensor amplifier.8 5-2. Circuitry and wiring chart.9 6. Performance.10 6-1. Output signal.10 6-2. Detection range.11 6-3. Cautions on installation .11 6-4. Timing chart .12 7.