Body Size: 40, Filter Type: A (Antibacterial Filter + Antibacterial Filter), Thread Type: N (NPT), Port Size: 03 (3/8)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 0 (Plug-in), Option: 1 (Direct Manual Override), Pilot: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: Side, Port Size: 03 (Sub-plate 3/8), Thread: N (NPT)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 03 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2), Thread: N (NPT)
Type of Actuation: 5 (3 Position Pressure Center), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 4 (220VAC 50/60HZ), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style), A, B Port Size: 03 (Body Ported/Base Mounted 3
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 2 (200VAC 50/60HZ), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: T (NPTF)
Body Size: 25, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: B (Assembly of a Bracket & Set Nuts), Semi-Standard: Y (Knob, Upward)
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: MN (M Plug Connector w/o Lead Wire), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Body Size: 40, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: B (Assembly of a Bracket & Set Nuts), Semi-Standard: Standard
Body Size: 25, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: B (Assembly of a Bracket & Set Nuts), Semi-Standard: 1R (1 + R)
Base Mounted Wiring: 01T (Plug-in w/Terminal Block), Stations: 9 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 03 (Rc3/8), Thread: T (NPTF)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: T (NPTF)
Body Size: 25, Thread: N (NPT), Port Size: 03 (3/8), Option: B (Assembly of a Bracket & Set Nuts), Semi-Standard: RYZ (R + Y + Z)
Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Stations: 2 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 03 (3/8)
Stations: 03 (3 Stations), Systems, Port Combinations: A [Ejector System, ø8 (Common PV)], Exhaust: 1 (Complex Exhaust), SI unit prefix: S (SI unit for EX260 or EX500), SI Unit: VA (EX260, CC-Link, NPN, M12), EX600 Output Polority, End Plate Type: Nil (without SI Unit, or not EX600), EX600, I/O Unit Stations: Nil (without I/O stations, or not EX600), Option: B (with DIN rail mounting bracket
Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 03 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: N7 (ø1/4" One-touch Fitting)
Type of Actuation: 5 (3 Position Pressure Center), Manifold Type: 40 (Base Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: LO (L Plug w/o Connector), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: MO (M Plug w/o Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 6 (12VDC), Electrical Entry: D (DIN Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 03 (Body Ported/Base Mounted 3/8), Thread: N (NPT)